:SEARch Commands 26
Agilent InfiniiVision 2000 X-Series Oscilloscopes Programmer's Guide 539
:SEARch:SERial:CAN:PATTern:DATA:LENGth
(see page 790)
Command Syntax
:SEARch:SERial:CAN:PATTern:DATA:LENGth <length>
<length> ::= integer from 1 to 8 in NR1 format
The :SEARch:SERial:CAN:PATTern:DATA:LENGth command specifies the
length of the data value when searching for Data Frame ID and Data.
The data value is specified using the :SEARch:SERial:CAN:PATTern:DATA
command.
Query Syntax
:SEARch:SERial:CAN:PATTern:DATA:LENGth?
The :SEARch:SERial:CAN:PATTern:DATA:LENGth? query returns the
current data length setting.
Return Format
<length><NL>
<length> ::= integer from 1 to 8 in NR1 format
See Also Chapter 26, “:SEARch Commands,” starting on page 531
":SEARch:SERial:CAN:MODE" on page 537
":SEARch:SERial:CAN:PATTern:DATA" on page 538