Agilent InfiniiVision 2000 X-Series Oscilloscopes Programmer's Guide 331
:MARKer:YUNits:USE
(see page 790)
Command Syntax
:MARKer:YUNits:USE
When PERCent is selected for :MARKer:YUNits, the :MARKer:YUNits:USE
command sets the current Y1 location as 0 percent and the current Y2
location as 100 percent.
Once the 0 and 100 percent locations are set, inputs to and outputs from
the :MARKer:Y1Position, :MARKer:Y2Position, and :MARKer:YDELta
commands/queries are relative to the set locations.
See Also "Introduction to :MARKer Commands" on page 318
":MARKer:YUNits" on page 330
":MARKer:X1Y1source" on page 321
":MARKer:X2Y2source" on page 323
":MEASure:SOURce" on page 361
":MARKer:Y1Position" on page 327
":MARKer:Y2Position" on page 328
":MARKer:YDELta" on page 329