368 Chapter 13
SCPI Command Reference
E5061A/E5062A commands
:SENS:CORR:COLL:ECAL:PATH?
Syntax :SENSe:CORRection:COLLect:ECAL:PATH? <numeric>
Description Reads out which port of the ECal module is connected with the specified port of the
E5061A/E5062A. (Query only)
Parameters
Query response {0|1|2|3|4}<newline><^END>
Example of use
10 OUTPUT 717;":SENS1:CORR:COLL:ECAL:PATH? 1"
20 ENTER 717;A
Equivalent key No equivalent key is available on the front panel.
<numeric>
Description Port number
Range 1 to 2
Resolution 1
Description
0 Nothing is connected.
1 Port A is connected.
2 Port B is connected.
3 Port C is connected.
4 Port D is connected.