204 Chapter 13
SCPI Command Reference
E5061A/E5062A commands
:CALC{1-4}:BLIM:DB
Syntax :CALCulate{[1]|2|3|4}[:SELected]:BLIMit:DB <numeric>
:CALCulate{[1]|2|3|4}[:SELected]:BLIMit:DB?
Description For channel 1 (:CALC1) to channel 4 (:CALC4) (specified with the
:CALC{1-4}:PAR{1-4}:SEL command), sets the bandwidth threshold value (attenuation
from the peak) of the bandwidth test.
Parameters
Query response {numeric}<newline><^END>
Example of use
10 OUTPUT 717;":CALC1:BLIM:DB 3"
20 OUTPUT 717;":CALC1:BLIM:DB?"
30 ENTER 717;A
Related commands :CALC{1-4}:PAR{1-4}:SEL on page 286
:CALC{1-4}:BLIM on page 203
Equivalent key
[Analysis] - Bandwidth Limit - N dB Points
<numeric>
Description Bandwidth N dB points
Range 0 to 5E8
Preset value 3