116 Chapter 4
Performance Tests
2. Image Rejection Test
Performance Tests
14.Set the spectrum analyzer reference level by pressing REFERENCE LEVEL and entering
the corresponding value for the band listed below:
for an 11974A:
40 dBm
for an 11974Q:
40 dBm
for an 11974U:
40 dBm
for an 11974V:
55 dBm
15.Set the spectrum analyzer center frequency by pressing
CENTER FREQUENCY and
entering the corresponding value for the band listed below:
for an 11974A: 26.5 GHz
for an 11974Q: 33 GHz
for an 11974U: 40 GHz
for an 11974V: 50 GHz
16.On the spectrum analyzer, press the following keys:
MARKER
NORMAL
PEAK SEARCH
PRESEL PEAK
17.When the preselector-peak routine is complete, press PEAK SEARCH.
18.Record the marker frequency in Table 4-8 on page 143.
19.On the spectrum analyzer, press MARKER
.
20.On the spectrum analyzer, press
CENTER FREQUENCY and use the key to tune to the
image response. Press
PEAK SEARCH to place the delta marker at the top of the image
response. The absolute value of the delta marker amplitude is the Image Rejection.
NOTE If the signal is buried in the noise floor, reduce the video bandwidth to 100 Hz
to help identify the signal. At some frequencies, however, instrument
performance is so good that an image response may not be visible.
21.Record the Image Rejection in Table 4-8 on page 143.
22.On the synthesized sweeper, press
CW and to increase the frequency of the
synthesized sweeper 500 MHz higher.
23.On the spectrum analyzer, set the
CENTER FREQUENCY to match the output frequency
of the signal source.