Agilent Technologies
Agilent
U1602B and U1604B
Handheld Digital
Oscilloscopes
Quick Start Guide
Przeglądanie stron 0
1 2 3 4 5 6 ... 17 18

Podsumowanie treści

Strona 1 - Oscilloscopes

Agilent TechnologiesAgilent U1602B and U1604B Handheld Digital Oscilloscopes Quick Start Guide

Strona 2 - Safety Information

9 Scope Connection ConfigurationConnect the scope in either single or dual channels with scope probes as shown in figure 3. Figure 3 Connection for

Strona 3

10 Meter Connection ConfigurationThe U1600B Series offers high precision, rugged auto ranging in true RMS with analog bar graph display. Enter Meter m

Strona 4 - Table of Contents

11 Cursor MeasurementUse cursor function to obtain a precise and accurate measurement in voltage and time at any desired point of a waveform. To enter

Strona 5 - The Front Panel at a Glance

12 Save/Recall Setup and WaveformTo enter Save/Recall mode, press and hold the Run/Stop button. This function allows you to save up to 10 waveforms an

Strona 6 - Getting Started

13 Trigger Menu Sub Menu DescriptionPattern TriggerMore 1/3 pageInput 1 Logic To select input logic 1 as CH1 High or Low and CH2 High or LowInput 1 Le

Strona 7

14 Automatic MeasurementsThe following automatic measurements can be accessed by pressing the Measure button. Up to four measurement menus with 22 mea

Strona 8 - To Compensate Scope Probe

15 Performance CharacteristicsPerformance Characteristic U1602B U1604BBandwidth 20 MHz40 MHzMaximum Real Time Sample Rate200 MSa/sChannels 2Maximum re

Strona 9 - Scope Screen Display

16 Performance Characteristics Data LoggerAuto range time span from 150 seconds to 20 days full screen display.Data logging for voltage, ohm and auxil

Strona 10

www.agilent.com© Agilent Technologies, Inc. 2006-2008Printed in MalaysiaFirst Edition, December 1, 2009U1602-90015Contact usTo obtain service, warrant

Strona 11

1 Use the product only as specified by the manufacturer. Do not install substitute parts or perform any unauthorized modification to the product. Retu

Strona 12 - Cursor Measurement

2 Prevention of fire or injury:• Use only the designated AC adapter and test leads supplied with the instrument.• Observe all ratings and markings of

Strona 13 - Signal Triggering

3 Table of ContentsSafety Information 1Introduction 4The Front Panel at a Glance 4Getting Started• To Inspect Package Contents 5 •To Ch

Strona 14

4 IntroductionThis quick start guide provides the basic information, front panel functions and general specifications of Agilent U1600B Series handhel

Strona 15 - Quick Help

5 Getting StartedTo Inspect Package ContentsInspect and verify the following items for the standard purchase of U1602B or U1604B, and any optional acc

Strona 16 - Performance Characteristics

6 To Charge a BatteryUpon delivery of the unit, the rechargeable battery is required to be fully charged for approximately 25 hours with the desig-n

Strona 17

7 To Select Language for Quick HelpOpen User menuOpen Utility menuSelect MORE 1/4 page menuSelect language (English/French/Italian/ Portuguese/Germa

Strona 18 - U1602-90015

8 Scope Screen Display Agilent U1600B Series offers a 320×240 color LCD display.No. Description / Function1 To display the status of channel 1 and cha