Infiniium 54800 Series
Oscilloscope Probes,
Accessories, and Options
Selection Guide Data Sheet
Table of Contents
Probe Compatibility Table ................................................................2
General Purpose Probes Overview ................................................3
116XA Family Passive Voltage ...................................................4
117XA Family Low Mass, Passive Voltage...............................7
High-Frequency Voltage Probes Overview ..................................9
1130A/31A/32A/34A InfiniiMax High-Performance
Active Probe System..................................................................10
1168A/69A InfiniiMax II High-Performance
Active Probe System..................................................................13
1155A Active Single-Ended Voltage........................................16
1156A/57A/58A High-Bandwidth, Active Voltage ..............18
1163A Resistive Divider...............................................................4
54006A Resistor Divider Probe ................................................21
Differential Voltage Probes Overview.........................................22
1130A/31A/32A/34A InfiniiMax High-Performance
Active Probe System..................................................................10
1168A/69A InfiniiMax II High-Performance
Active Probe System..................................................................13
1153A Low-Bandwidth Active Differential Voltage..............23
Current Probes Overview...............................................................26
1146A ac/dc Current .................................................................27
1147A High Bandwidth ac/dc Current ...................................29
High-Voltage Passive Probes Overview .....................................31
10076A (100:1)............................................................................32
N2771A (1000:1).........................................................................33
Mixed-Signal Oscilloscope Logic Probe Kit..............................34
E5396A Half-Size Soft Touch Connectorless Logic Probe.......35
Probing Accessories.......................................................................36
Wedge Adapters.........................................................................36
0.5 mm IC Clips, PC Board Mini-Probe Sockets ....................37
EZ-Probe Positioner ...................................................................38
Logic Analyzer/Oscilloscope Time Correlation........................39
VoiceControl .....................................................................................40
Input Devices and Storage Devices.............................................41
E2610A Keyboard, E2609B Rackmount Kit,
1184A Testmobile.......................................................................41
Infiniium Advanced Analysis Options .........................................42
Support, Services, and Assistance..............................................43
To ensure that you have the tools for dependable
oscilloscope measurements, Agilent Technologies
offers a wide range of oscilloscope probes and
accessories. Each is designed for a specific
measurement need because the physical and
electrical quality of the connection can make
the difference between a good measurement
and a bad one.
99 Washington Street
Melrose, MA 02176
Fax 781-665-0780
TestEquipmentDepot.com
Przeglądanie stron 0
1 2 3 4 5 6 ... 41 42

Podsumowanie treści

Strona 1 - Accessories, and Options

Infiniium 54800 SeriesOscilloscope Probes, Accessories, and OptionsSelection Guide Data SheetTable of ContentsProbe Compatibility Table ...

Strona 2 - Probe Compatibility Table

High-Frequency Active Differential/Single-Ended Probe SystemAgilent 1130A/31A/32A/34A InfiniiMax High-Performance Active Probe System• The Agilent Inf

Strona 3

High-Frequency Active Differential/Single-Ended Probe SystemAgilent 1130A/31A/32A/34A InfiniiMax High-Performance Active Probe SystemSpecificationsOpe

Strona 4 - General Purpose Probes

High-Frequency Active Differential/Single-Ended Probe SystemAgilent 1130A/31A/32A/34A InfiniiMax High-Performance Active Probe SystemOrdering Informat

Strona 5

13Two new high-bandwidth InfiniiMax IISeries probe amplifiers have been added tothe InfiniiMax product line. InfiniiMax Iprobe amplifiers and probe he

Strona 6

14High-Frequency Active Differential/Single-Ended Probe SystemAgilent 1168A/69A InfiniiMax II High-Performance Active Probe SystemSpecificationsOperat

Strona 7

15High-Frequency Active Differential/Single-Ended Probe SystemAgilent 1168A/69A InfiniiMax II High-Performance Active Probe SystemOrdering Information

Strona 8

16Figure 3.8. Agilent 1155A for fine-pitch ICs, SMDs, and densecircuit boards.High-Frequency Active Single-Ended Voltage ProbesAgilent 1155A Active Si

Strona 9

17SpecificationsOperating CharacteristicsBandwidth (–3 dB) dc to ≥ 750 MHzSystem bandwidth 500 MHz with 600 MHz 54830B/D, 31B/D scopes670 MHz with 1 G

Strona 10

18High-Frequency Active Single-Ended Voltage ProbesAgilent 1156A/57A/58A High-Bandwidth, Active Single-Ended Voltage• Ideal for a range of hi-speed ap

Strona 11 - Example of characterized

19SpecificationsOperating CharacteristicsBandwidth (–3 dB) 1156A: > 1.5 GHz; 1157A: > 2.5 GHz; 1158A: > 4 GHzSystem bandwidth (–3 dB) 1156A w

Strona 12 - Ordering Information

For ordering information when replac-ing your probe or probe accessory:Refer directly to the page numberlisted in the table of contents foryour probe

Strona 13 - InfiniiMax II probe heads

20Twelve 130 Ωresistive signalpins (orange)*Accessories SuppliedTwo solderable-tip5 cm resistive signal leads*Two socket-end 5 cmresistive signal lead

Strona 14 - Specifications

21High-Frequency Passive Voltage ProbeAgilent 54006A 6 GHz Resistor Divider ProbeThe Agilent 54006A allows you toprobe signals up to 6 GHz usingreplac

Strona 15

22Differential Voltage Probes OverviewDifferential probes are activeprobes with two inputs, one posi-tive and one negative, as well as aseparate groun

Strona 16

23Reliable Probing of Low-Bandwidth Signals The Agilent 1153A is a 1:1 FETdifferential probe with 200 MHzbandwidth and 3000:1 CMRR(Common Mode Rejecti

Strona 17

24SpecificationsOperating CharacteristicsBandwidth (–3 dB) dc to 200 MHz [1]Rise time 1.75 ns calculated from tr= (0.35/bandwidth)dc gain accuracy* 2%

Strona 18 - • Accessories designed for

25Ordering InformationProbe and AccessoriesPart # Description Quantity1153A 200 MHz differential probe 15959-9335 Long (5.5 inch) test lead 5IC clips:

Strona 19

26Current Probes OverviewCurrent probes sense the currentflowing through a conductor andconvert it to a voltage that can beviewed and measured on an o

Strona 20

27Within Budget, Without CompromiseThe low-cost 1146A probeexpands oscilloscope applicationsin industrial, automotive andpower environments and is ide

Strona 21

28SpecificationsOperating CharacteristicsCurrent range* 100 mV/A: 100 mA to 10 A peak; 10 mV/A: 1 to 100 A peakOutput signal 1000 mV peak maxac curren

Strona 22

29Accurate Current MeasurementsWithout Breaking the CircuitThe 1147A is a wide bandwidth,dc to 50 MHz, current probe. Theprobe offers flat frequencyre

Strona 23

General Purpose Probes OverviewPassive voltage probes are usedfor general purpose probing andare made with passive compo-nents only such as wires, con

Strona 24

30Operating CharacteristicsBandwidth (–3 dB) dc to 50 MHzRise time17 nsAccuracy* ±1% of reading ±1 mVMaximum continuous current 15 A (acrms + dc) Refe

Strona 25

31High-Voltage Passive Probes OverviewHigh-voltage probes are used forvoltages higher than can be han-dled safely with general-purpose10:1 passive pro

Strona 26 - Current Probes Overview

32The 10076A provides the features you need to capturefast, high-voltage signals. Itscompact design makes it easy toprobe today’s small, power electro

Strona 27 - Agilent 1146A ac/dc Current

33SpecificationsOperating CharacteristicsBandwidth (–3 dB) 50 MHzRise time (calculated) < 7 nsAttenuation ratio 1000:1Input resistance 100 MΩ (when

Strona 28

34Mixed-Signal Oscilloscope Logic Probe Kit• Same cable used for high-performance Agilent logic analyzers• Flying leads offer flexibility and convenie

Strona 29

35Agilent E5396A Half-Size Soft Touch Connectorless Logic Probe• 17 channels, single-ended clockand data • < 0.7 pF equivalent load capacitance • C

Strona 30

36Probing AccessoriesWedge AdaptersAgilent Wedge Probe Adapters• Secure connection to 0.5 mm and0.65 mm TQFP and PQFP devices• Won’t fall off, short a

Strona 31

37Figure 9.3. Horizontal and vertical versionsof the PC board mini-probe socket make iteasy to fit into your target board.0.5 mm IC Clips• Extremely s

Strona 32 - Agilent 10076A (100:1)

38EZ-Probe Positioner• Stable X, Y, Z positioning• 3-D joystick, 3:1 motion reduction• Compatible with all Agilent hand-held probesThe revolutionary E

Strona 33 - Agilent N2771A (1000:1)

39Logic Analyzer/Oscilloscope Time Correlation• Verify correct logical relationshipsbetween analog and digital portions of a design• Cross-trigger and

Strona 34

Built for ReliabilityThese general purpose replace-ment devices are built and testedfor high reliability. Kevlarstrengthener has been added tothe prob

Strona 35 - Figure 8.1. E5396A

40VoiceControl• Hands-free scope operation• Speaker and gender independent• Uses simple English commandsIf you’re making multi-channelmeasurements on

Strona 36 - Wedge Adapters

411184A TestmobileThe Agilent 1184A testmobilegives you a convenient means oforganizing and transporting yourInfiniium oscilloscope and acces-sories.

Strona 37

42Related LiteraturePublication Title Publication Type Publication NumberAgilent Technologies Digital and Selection Guide 5988-8460EN/ENUSMixed Signa

Strona 38 - EZ-Probe Positioner

SpecificationsSystemModel Bandwidth Division Scope CompensationNumber Type of Probe (scope +probe) Ratio Input R Input C Input R Range Length1160A Hig

Strona 39

Ordering InformationProbes and AccessoriesPart # Description Quantity1160A 10:1, 10 MΩ, 1.5 m, miniature passive probe 11161A 10:1, 10 MΩ, 1.5 m, mini

Strona 40 - VoiceControl

Suited for Today’s ICsAn exceptionally small and lightprobe tip (<1 gram) and an ultrathin cable make the 117XA familyideal for connecting to and p

Strona 41

SpecificationsOperating CharacteristicsApproximate propagation delay 1171A: 6.5 nsMaximum input voltage 40 V (dc + peak ac), CAT ISafety Meets IEC10

Strona 42 - Related Literature

High-Frequency Voltage Probes OverviewActive voltage probes contain anactive component, usually a field-effect transistor (FET), and there-fore need t