Command Reference
Status Subsystem (:STATus)
Chapter 4200
:QUEStionable:MODulation:ENABle
Supported PSG-A Series
:STATus:QUEStionable:MODulation:ENABle <value>
:STATus:QUEStionable:MODulation:ENABle?
This command determines what bits in the Data Questionable Modulation Event
Register will set the modulation summary bit (bit 7) in the Data Questionable Condition
Register.
The variable <value> is the sum of the decimal values of the bits that you want to
enable.
*RST N/A
Range 0–32767
Key Entry N/A
Remarks Refer to “Data Questionable Modulation Status Group” on page 130
and “Data Questionable Modulation Event Enable Register” on
page 132 for more information.
:QUEStionable:MODulation:NTRansition
Supported PSG-A Series
:STATus:QUEStionable:MODulation:NTRansition <value>
:STATus:QUEStionable:MODulation:NTRansition?
This command determines what bits in the Data Questionable Modulation Condition
Register will set the corresponding bit in the Data Questionable Modulation Event
Register when that bit has a negative transition (1 to 0).
The variable <value> is the sum of the decimal values of the bits that you want to
enable.
*RST N/A
Range 0–32767
Key Entry N/A
Remarks Refer to “Data Questionable Modulation Status Group” on page 130 for
more information.