Agilent Technologies E4400-60230 g Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Generatory prądu Agilent Technologies E4400-60230 g. Installation Note E4400-90218 Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 18
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Part Number E4400-90218
Printed in USA May 2000 Supersedes February 2000
Installation Note
Agilent Technologies ESG–D and ESG–DP
Series Signal Generators
Upgrade Kit for Option UN8
Kit Part Number E4400-60170
Models: E4430B, E4431B, E4432B, E4433B, E4434B,
E4435B, E4436B, and E4437B
Przeglądanie stron 0
1 2 3 4 5 6 ... 17 18

Podsumowanie treści

Strona 1 - Installation Note

Part Number E4400-90218Printed in USA May 2000 Supersedes February 2000Installation NoteAgilent Technologies ESG–D and ESG–DPSeries Signal GeneratorsU

Strona 2

10 Installation Note E4400-90218Removing Hardware (Options UN7/UND not Installed)Removing the Rear Panel1. Refer to Figure 3. Remove the 15 screws (it

Strona 3 - Introduction

Installation Note E4400-90218 114. Remove the nut (not shown) that secures the serial tag (item 9). Then remove the serial tag.5. Discard the old rea

Strona 4 - Parts List

12 Installation Note E4400-90218UN8 Installation (Options UN7/UND not Installed)Assembling and Installing the Rear Panel1. Using the 8 washers and 8 h

Strona 5

Installation Note E4400-90218 13Modifying the Front Panel1. Refer to Figure 5. Remove the I–INPUT (W1) and Q–INPUT (W2) BNCs from the front panel.2.

Strona 6 - Tools Required

14 Installation Note E4400-90218Installing the A7 and A8 Assemblies1. Refer to Figure 6. Insert the Board Assy-Generator/1 Meg (A8) into the A14J4 mot

Strona 7 - Utility > Error Info

Installation Note E4400-90218 15Figure 6 Option UN8 (Options UN7/UND not Installed) Top ViewFigure 7 Cables W25 and W26

Strona 8

16 Installation Note E4400-90218UN8 Installation (Options UN7/UND Installed)Installing the A7 and A8 Assemblies1. Refer to Figure 8. If the A7 or A8 b

Strona 9

Installation Note E4400-90218 17Figure 8 Option UN8 (Options UN7/UND Installed) Top ViewFigure 9 Cables W25 and W26

Strona 10 - Removing the Rear Panel

18 Installation Note E4400-90218Completing the Installation (All Signal Generators)Installing New FirmwareThe firmware upgrade kit contains an installa

Strona 11

NoticeThe information contained in this document is subject to change without notice.Agilent Technologies makes no warranty of any kind with regard to

Strona 12

Installation Note E4400-90218 3IntroductionThis installation note covers different configurations of signal generators depending on whetherOptionUN7 o

Strona 13 - Modifying the Front Panel

4 Installation Note E4400-90218E4400-60170 Upgrade Kit (Add Option UN8)Use this upgrade kit to add Option UN8 Real-Time I/Q Baseband Generator with TD

Strona 14 - Connecting Cables

Installation Note E4400-90218 524 1 0 0 Installation Note E4400-9021825b2 0 0 SMB to BNC Cable (W25 & W26) 8120-878126 1 0 0 ESG Digital Document

Strona 15 - Figure 7 Cables W25 and W26

6 Installation Note E4400-90218Tools RequiredWARNING Before you disassemble the instrument, turn the power switch off, andunplug the instrument. Failu

Strona 16

Installation Note E4400-90218 7Verifying the Functionality of the Signal GeneratorThis procedure verifies that the signal generator powers up and that

Strona 17 - Figure 9 Cables W25 and W26

8 Installation Note E4400-90218Removing the Top Chassis Cover (All Signal Generators)1. Turn the instrument’s power switch off, and unplug the instrum

Strona 18 - Activating Option UN8

Installation Note E4400-90218 9Figure 2 Top Chassis Cover Removal

Komentarze do niniejszej Instrukcji