145
U7232A DisplayPort Electrical Performance Compliance Test Application
Method of Implementation
Agilent Technologies
s
17
Link Layer Protocol Tests
Probing for Link Layer Protocol Tests 146
Link Layer Protocol Tests 147
This section provides the guidelines for link layer protocol tests using an
Agilent 8 GHz or greater Infiniium oscilloscope, InfiniiMax probes, and the
DisplayPort Electrical Performance Compliance Test Application. Link layer
protocol tests are not compliance tests. The purpose of these tests is to
verify if the link layer protocol is operating properly prior to any tests.
These tests verify if the DUT is able to respond well when the
configuration of the link layer is changed.