Agilent Technologies InfiniiVision 3000 DSO-X 3054A Instrukcja Obsługi Strona 753

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 970
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 752
:WGEN Commands 30
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide 753
:WGEN:PERiod
(see page 860)
Command Syntax
:WGEN:PERiod <period>
<period> ::= period in seconds in NR3 format
For Sine, Square, Ramp, and Pulse waveforms, the :WGEN:PERiod
command specifies the period of the waveform.
You can also specify the period indirectly using the :WGEN:FREQuency
command.
Query Syntax
:WGEN:PERiod?
The :WGEN:PERiod? query returns the currently set waveform generator
period.
Return Format
<period><NL>
<period> ::= period in seconds in NR3 format
See Also "Introduction to :WGEN Commands" on page 744
":WGEN:FUNCtion" on page 746
":WGEN:FREQuency" on page 745