:SBUS<n> Commands 24
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide 495
:SBUS<n>:IIC:ASIZe
(see page 860)
Command Syntax
:SBUS<n>:IIC:ASIZe <size>
<size> ::= {BIT7 | BIT8}
The :SBUS<n>:IIC:ASIZe command determines whether the Read/Write bit
is included as the LSB in the display of the IIC address field of the
decode bus.
Query Syntax
:SBUS<n>:IIC:ASIZe?
The :SBUS<n>:IIC:ASIZe? query returns the current IIC address width
setting.
Return Format
<mode><NL>
<mode> ::= {BIT7 | BIT8}
Errors "- 241, Hardware missing" on page 823
See Also "Introduction to :SBUS<n> Commands" on page 453
":SBUS<n>:IIC Commands" on page 494