Agilent Technologies ESG Instrukcja Użytkownika Strona 7

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 28
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 6
7
Frequency modulation
Maximum deviation
ESG-A and ESG-AP and
ESG-D series ESG-DP series
N x 10 MHz N x 1 MHz
Resolution 0.1% of deviation or 1 Hz,
whichever is greater
Modulation frequency response (deviation = 100 kHz)
1
Rates
1 dB bandwidth 3 dB bandwidth, typical
FM1 dc/20 Hz to 100 kHz dc/5 Hz to 10 MHz
FM2 dc/20 Hz to 100 kHz dc/5 Hz to 1 MHz
Deviation accuracy
2
<±(3.5% of FM deviation + 20 Hz)
(1 kHz rate, deviation < N x 100
kHz)
Carrier frequency accuracy relative to CW in dcFM
2,3
±0.1% of set deviation + (N x 1
Hz)
Distortion
2
<1%
(1 kHz rate, THD, dev.= N x 100 kHz)
External inputs Ext 1 or Ext 2
Sensitivity 1 V
peak
for indicated deviation
Input impedance 50 , nominal
Paths FM 1 and FM 2 are summed internally for composite
modulation. Either path may be switched to any one of the mod-
ulation sources: Int, Ext 1, Ext 2. The FM 2 path is limited to a
maximum rate of 1 MHz. The FM 2 path must be set to a devia-
tion less than FM 1.
Phase modulation
Maximum deviation
2
ESG-A and ESG-D ESG-AP and ESG-DP
series series
Normal BW N x 90 radians N x 10 radians
High BW N x 90 radians N x 1 radian
Resolution 0.1% of set deviation
Modulation frequency response
2
ESG-A and ESG-D series
Maximum Rates (3 dB BW)
Mode deviation ΦM1 ΦM2
Normal BW N x 90 rad dc to 100 kHz dc to 100 kHz
High BW N x 2π rad dc to 1.5 MHz (typ) dc to 0.9 MHz (typ)
N x π/2 rad dc to 4 MHz (typ) dc to 1 MHz (typ)
ESG-AP and ESG-DP series
Maximum Rates (3 dB BW)
Mode deviation ΦM1 ΦM2
Normal BW N x 10 rad dc to 100 kHz dc to 100 kHz
High BW N x 1 rad dc to 1 MHz (typ) dc to 1 MHz (typ)
Deviation accuracy <±(5% of deviation + 0.01 radians)
(1 kHz rate, Normal BW mode)
Distortion
2
<1%
1 kHz rate, THD, dev <N x 90 rad (dev < N x 10 rad for HP ESG-
AP
and ESG-DP series), Normal BW mode
External inputs Ext 1 or Ext 2
Sensitivity 1 Vpeak for indicated deviation
Input impedance 50 , nominal
Paths ΦM 1 and ΦM 2 are summed internally for composite
modulation. Either path may be switched to any one of the
modulation sources: Int, Ext 1, Ext 2. The ΦM 2 path is limited
to a maximum rate of 1 MHz. The ΦM 2 path must be set to a
deviation less than ΦM 1.
1. Since the internal modulation source operates over 0.1 Hz to 50 kHz, FM rates above 50 kHz must be supplied externally.
2. Refer to frequency bands on page 4 to compute specifications.
3. At the calibrated deviation and carrier frequency, within 5° C of ambient temperature at time of calibration.
Przeglądanie stron 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 27 28

Komentarze do niniejszej Instrukcji

Brak uwag