Agilent Technologies N9344C Instrukcja Obsługi Strona 1

Przeglądaj online lub pobierz Instrukcja Obsługi dla Pomiary, testowanie i kontrola Agilent Technologies N9344C. Agilent Technologies N9344C Technical data Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 224
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - Spectrum Analyzer

Agilent N9342C/43C/44CHandheld Spectrum AnalyzerProgrammer’s Guide

Strona 2

2 Programmer’s Guide1 Getting StartedRemotely Operating the AnalyzerThe analyzer provides both the USB and LAN connection which allows you to set up a

Strona 3 - In This Guide…

92 Programmer’s Guide5 Command ReferenceLimit Line Y-axis Value:CALCulate:LLINe[1]:Y <value>:CALCulate:LLINe[1]:Y?Sets the Y-axis value of a lim

Strona 4 - Programmer’s Guide

Command Reference 5Programmer’s Guide 93Limit Beep State:CALCulate:LLINe:CONTrol:BEEP OFF|ON|0|1:CALCulate:LLINe:CONTrol:BEEP?Use this command to turn

Strona 5 - Contents

94 Programmer’s Guide5 Command ReferenceSet the limits Margin Value:CALCulate:LLINe[1]|2:MARGin <value>:CALCulate:LLINe[1]|2:MARGin?Use this com

Strona 6

Command Reference 5Programmer’s Guide 95Marker SubsectionMarkers All Off on All Traces:CALCulate:MARKer:AOFFTurns off all markers on all the traces.Ke

Strona 7

96 Programmer’s Guide5 Command ReferenceMarker Function:CALCulate:MARKer[1]|2|3|4|5|6:FUNCtion FCOunt|NOISe|OFF:CALCulate:MARKer[1]|2|3|4|5|6:FUNCtion

Strona 8

Command Reference 5Programmer’s Guide 97Marker Peak Left/Right Search:CALCulate:MARKer[1]|2|3|4|5|6:MAXimum:LEFT:CALCulate:MARKer[1]|2|3|4|5|6:MAXimum

Strona 9 - Getting Started

98 Programmer’s Guide5 Command ReferencePeak Search Type:CALCulate:MARKer:PEAK:SEARch:MODE MAXimum|MINi-mum:CALCulate:MARKer:PEAK:SEARch:MODE?Specifie

Strona 10 - ® II or higher required

Command Reference 5Programmer’s Guide 99Marker to Center:CALCulate:MARKer[1]|2|3|4|5|6[:SET]:CENTerThis command sets the center frequency equal to the

Strona 11

100 Programmer’s Guide5 Command ReferenceMarker On/Off:CALCulate:MARKer[1]|2|3|4|5|6:STATe OFF|ON|0|1:CALCulate:MARKer[1]|2|3|4|5|6:STATe?This command

Strona 12

Command Reference 5Programmer’s Guide 101Query Marker Readout: Y Value:CALCulate:MARKer[1]|2|3|4|5|6:Y?This command reads the current Y value for the

Strona 13

Getting Started 1Programmer’s Guide 3Connecting the Analyzer via the USB PortNo extra driver is required to connect the analyzer via the USB port to a

Strona 14

102 Programmer’s Guide5 Command ReferenceInitiate SubsystemThe INITiate subsystem is used to control the initiation of the spectrum analyzer sweep ope

Strona 15

Command Reference 5Programmer’s Guide 103*RST: ContinuousKey access: Sweep > Sweep Single/ContInitiate a Single Sweep:INITiate[:IMMediate]This comm

Strona 16 - 1 Getting Started

104 Programmer’s Guide5 Command ReferenceTrigger SubsystemThe TRIGger subsystem is used to set the controls and parameters associated with triggering

Strona 17 - Programming Fundamentals

Command Reference 5Programmer’s Guide 105Video Trigger Level Amplitude:TRIGger[:SEQuence]:VIDeo:LEVel <value>:TRIGger[:SEQuence]:VIDeo:LEVel?Spe

Strona 18 - Overview

106 Programmer’s Guide5 Command ReferenceRF Burst Trigger Slope:TRIGger[:SEQuence]:RFBurst:SLOPe POSitive|NEGative:TRIGger[:SEQuence]:RFBurst:SLOPe?Th

Strona 19

Command Reference 5Programmer’s Guide 107Synchronization Source:TRIGger[:SEQuence]:FRAMe:SYNC OFF|EXTernal |RFBurst:TRIGger[:SEQuence]:FRAMe:SYNC?Spec

Strona 20 - Command Categories

108 Programmer’s Guide5 Command ReferencePower Measurement SubsystemThe Power Measurement Subsystem provides you the SCPI commands reference for the H

Strona 21 - Command Syntax

Command Reference 5Programmer’s Guide 109Adjacent Channel State[:SENSe]:ACPRatio:OFFSet:LIST:STATe OFF|ON|0|1,OFF|ON|0|1,OFF|ON|0|1,OFF|ON|0|1,OFF|ON|

Strona 22 - Command Example

110 Programmer’s Guide5 Command ReferenceChannel Space[:SENSe]:ACPRatio:OFFSet:LIST[FREQuency] <freq>,<freq>,<freq>,<freq>,<

Strona 23 - Creating Valid Commands

Command Reference 5Programmer’s Guide 111Query Upper Adjacent Channel Power Ratio:MEASure:ACPRatio:UPPer?Return the upper adjacent channel power to ma

Strona 24 - Program and Response Messages

4 Programmer’s Guide1 Getting Started4 After a while, the PC finds your analyzer as a new hardware and prompts a message saying “Found new hardware...

Strona 25 - Parameters in Commands

112 Programmer’s Guide5 Command ReferenceIntegration BW[:SENSe]:CHPower:BWIDth|BANDwidth:INTegration <freq>[:SENSe]:CHPower:BWIDth|BANDwidth:INT

Strona 26 - Variable Parameters

Command Reference 5Programmer’s Guide 113Channel Power Auto Range[:SENSe]:CHPower:METer:RANGe:AUTO OFF|ON|0|1[:SENSe]:CHPower:METer:RANGe:AUTO? Toggle

Strona 27 - Status Registers

114 Programmer’s Guide5 Command ReferenceQuery Channel Power and Density Result:MEASure:CHPower?This command returns scalar results of main channel po

Strona 28

Command Reference 5Programmer’s Guide 115Channel Power RRC Filter Bandwidth[:SENSe]:CHPower:RRC:BW <value>[:SENSe]:CHPower:RRC:BW?Use this comma

Strona 29 - Access the status registers

116 Programmer’s Guide5 Command ReferenceSet dBc method of OBW[:SENSe]:OBWidth:XDB <value>[:SENSe]:OBWidth:XDB?specify the power level used to d

Strona 30

Command Reference 5Programmer’s Guide 117Query OBW Result:MEASure:OBW:OBW?:FETCh:OBW:OBW?Use this command to query the occupied bandwidth according to

Strona 31

118 Programmer’s Guide5 Command ReferenceSEM Channel Integrate Bandwidth[:SENSe]:SEMask:BANDwidth|BWIDth:INTegration <freq>[:SENSe]:SEMask:BANDw

Strona 32 - Status Register Examples

Command Reference 5Programmer’s Guide 119SEM Channel Span[:SENSe]:SEMask:FREQuency:SPAN <freq>[:SENSe]:SEMask:FREQuency:SPAN?Use this command to

Strona 33 - Status Register System

120 Programmer’s Guide5 Command ReferenceQuery SEM Marker Y Value[:SENSe]:SEMask:MARKer[1]|2|3|4|5|6:Y?Use this command to query the marker readout of

Strona 34 - The Status Byte Register

Command Reference 5Programmer’s Guide 121SEM Offset Measurement Bandwidth[:SENSe]:SEMask:OFFSet:LIST:BAND-width|BWIDth:MEASure <Integer>, <In

Strona 35

Getting Started 1Programmer’s Guide 57 PC will detect the instrument automatically. The item “USB Test and Measurement Device” displays in the pop-up

Strona 36 - 3 4 5 6 7

122 Programmer’s Guide5 Command ReferenceSEM Offset Sweep Time[:SENSe]:SEMask:OFFSet:LIST:SWEeptime <time>,<time>,<time>,<time>

Strona 37

Command Reference 5Programmer’s Guide 123SEM Offset Rel StartAmpt[:SENSe]:SEMask:OFFSet:LIST:STARt:RCARrier <ampl>,<ampl>,<ampl>,<

Strona 38

124 Programmer’s Guide5 Command ReferenceSEM Offset Fail Mask[:SENSe]:SEMask:OFFSet:LIST:TEST ABSolute|RELa-tive|AND|OR,ABSolute|RELative|AND|OR,ABSo-

Strona 39 - Programming Example

Command Reference 5Programmer’s Guide 125Query SEM Lower Offset Peak Frequency[:SENSe]:SEMask:OFFSet:LIST:LOWer:PEAK:FRE-Quency?Use this command to qu

Strona 40

126 Programmer’s Guide5 Command ReferenceSEM Fail Setting Hold[:SENSe]:SEMask:FAIL:LOG OFF|ON|0|1[:SENSe]:SEMask:FAIL:LOG?Use this command to switch t

Strona 41

Command Reference 5Programmer’s Guide 127Spectrum Monitor Option SubsystemThe spectrum monitor subsystem provides you the SCPI commands reference for

Strona 42 - Example Program

128 Programmer’s Guide5 Command ReferenceSpectrogram Palette[:SENSe]:SPECtrogram:PALette FCOLor|GRAY[:SENSe]:SPECtrogram:PALette?This command switches

Strona 43 - Opening a Session

Command Reference 5Programmer’s Guide 129Spectrogram Marker Time[:SENSe]:SPECtrogram:MARKer[1]|2:TIME <value>[:SENSe]:SPECtrogram:MARKer[1]|2:TI

Strona 44 - Device Sessions

130 Programmer’s Guide5 Command ReferenceSpectrogram Marker Band Power State[:SENSe]:SPECtrogram:MARKer:BPOWer:STATe OFF|ON|0|1[:SENSe]:SPECtrogram:MA

Strona 45

Command Reference 5Programmer’s Guide 131Spectrogram Marker Audio Alert Limit[:SENSe]:SPECtrogram:MARKer:ALERt:LIMit <value>[:SENSe]:SPECtrogram

Strona 46 - Closing a Session

6 Programmer’s Guide1 Getting StartedConnecting the Analyzer via the LAN PortNo extra driver is required to connect the analyzer via the LAN port to a

Strona 47 - Checking the USB Connection

132 Programmer’s Guide5 Command ReferenceSpectrogram Save Start Date[:SENSe]:SPECtrogram:SAVE:TIMed:STARt:DATE <“str”>[:SENSe]:SPECtrogram:SAVE:

Strona 48 - 4 Programming Example

Command Reference 5Programmer’s Guide 133Spectrogram Save File Type[:SENSe]:SPECtrogram:SAVE:FTYPe TRC|CSV[:SENSe]:SPECtrogram:SAVE:FTYPe?Use this com

Strona 49 - Programmer’s Guide 41

134 Programmer’s Guide5 Command ReferenceCable and Antenna Test Option SubsystemThe Cable and Antenna Test Option Subsystem provides you the SCPI comm

Strona 50 - 42 Programmer’s Guide

Command Reference 5Programmer’s Guide 135CAT IIM State[:SENSe]:CAT:IIM[:STATe] OFF|ON|0|1[:SENSe]:CAT:IIM[:STATe]?Use this command to turn on/off IIM

Strona 51 - Programmer’s Guide 43

136 Programmer’s Guide5 Command ReferenceCAT Select A Cable[:SENSe]:CAT:CABLe:LOAD <string>Use this command to select a cable from built-in cabl

Strona 52 - 44 Programmer’s Guide

Command Reference 5Programmer’s Guide 137CAT Windows Select[:SENSe]:CAT:WINDow NONE|RECTangular|HAMMing|S3BLackman|S4BLackman[:SENSe]:CAT:WINDow?This

Strona 53 - Programmer’s Guide 45

138 Programmer’s Guide5 Command ReferenceCAT Center Frequency[:SENSe]:CAT:FREQuency:CENTer <freq>[:SENSe]:CAT:FREQuency:CENTer?This command defi

Strona 54 - 46 Programmer’s Guide

Command Reference 5Programmer’s Guide 139CAT Distance Unit[:SENSe]:CAT:DISTance:UNIT METers|FEET[:SENSe]:CAT:DISTance:UNIT?Use this command to toggle

Strona 55 - Programmer’s Guide 47

140 Programmer’s Guide5 Command ReferenceCAT Amplitude Scale Per Division[:SENSe]:CAT:SCALe:DIV <value>[:SENSe]:CAT:SCALe:DIV?This command defin

Strona 56 - 48 Programmer’s Guide

Command Reference 5Programmer’s Guide 141CAT Trace Math Type[:SENSe]:CAT:TRACe:MATH OFF|ADD|SUB|DIV[:SENSe]:CAT:TRACe:MATH?This command toggles the tr

Strona 57 - Command Reference

Getting Started 1Programmer’s Guide 76 Press “Test Connection” to check the LAN connection. The figure below indicates that the connection is ready.7

Strona 58 - IEEE Common Commands

142 Programmer’s Guide5 Command ReferenceCAT Trace Data Query:TRACe[:DATA]? DATA|MEMUse this command to query the current trace data.Example: :TRACe?

Strona 59 - Operation Complete Query

Command Reference 5Programmer’s Guide 143CAT Marker Continuous Peak State:CALCulate:MARKer[1]|2|3|4|5|6:CPEak OFF|ON|0|1:CALCulate:MARKer[1]|2|3|4|5|6

Strona 60 - Status Byte Query

144 Programmer’s Guide5 Command ReferenceCAT Query Reference Marker X axis Value:CALCulate:MARKer[1]|2|3|4|5|6:RX?This command query current reference

Strona 61 - Wait-to-Continue

Command Reference 5Programmer’s Guide 145CAT Limit Type:CALCulate:LLINe[1]|2:TYPE UPPer|LOWer:CALCulate:LLINe[1]|2:TYPE?This command toggles the limit

Strona 62 - System Subsystem

146 Programmer’s Guide5 Command ReferenceCAT Get Limits Result:CALCulate:LLINe[1]|2:FAIL?This command query the result of limit line or limit in cable

Strona 63 - Language Type

Command Reference 5Programmer’s Guide 147CAT Define Limit Value:CALCulate:LLINe[1]|2:DATA <x-axis>,<ampl>,<connected>{,<x-axis>

Strona 64 - System Error

148 Programmer’s Guide5 Command ReferenceChannel Scanner Option SubsystemThe Channel Scanner Option Subsystem provides you the SCPI command reference

Strona 65 - BNC Port Input Type Setting

Command Reference 5Programmer’s Guide 149Bottom N Number:CHSCanner:SWEep:BOTTom <value>:CHSCanner:SWEep:BOTTom?This command specify the scanner

Strona 66 - IP Address Assignment

150 Programmer’s Guide5 Command ReferenceMin Hold Dwell Time:CHSCanner:SWEep:MINHold:DWELltime <value>:CHSCanner:SWEep:MINHold:DWELltime?Use thi

Strona 67 - Erase Memory

Command Reference 5Programmer’s Guide 151Measurement Interval State:CHSCanner:SWEep:INTerval[:STATe] OFF|ON|0|1:CHSCanner:SWEep:INTerval [:STATe]?Use

Strona 68 - Sync to GPS Status

8 Programmer’s Guide1 Getting Started

Strona 69 - Time Power On Time

152 Programmer’s Guide5 Command ReferenceTop N/Bottom N Measurement Rule:CHSCanner:SWEep:TOPBottom:RULE:MEASure SPEed|ACCUracy:CHSCanner:SWEep:TOPBott

Strona 70 - Time Power Off Time

Command Reference 5Programmer’s Guide 153Bottom Cycle:CHSCanner:SWEep:BOTTom:CYCLe[:STATe] OFF|ON|0|1:CHSCanner:SWEep:BOTTom:CYCLe[:STATe]?Use this co

Strona 71 - Save User Preset

154 Programmer’s Guide5 Command ReferenceChannel Scanner Edit SubsectionSet Channel Edit Method for List Sweep:CHSCanner:EDIT:LIST:METHod <index>

Strona 72 - Speaker Volume

Command Reference 5Programmer’s Guide 155Modify Channel By Custom For List Sweep:CHSCanner:EDIT:LIST:MODify:CUSTom <index>,<freq>,<band

Strona 73 - System Time Sync to GPS

156 Programmer’s Guide5 Command ReferenceQuery Channel Information For List Sweep:CHSCanner:EDIT:LIST?This command query the scan channel information

Strona 74 - Memory Subsystem

Command Reference 5Programmer’s Guide 157Set Scan Channel Range For Top N Sweep By Signal Standard:CHSCanner:EDIT:TOP:STD:RANGe <value>,<valu

Strona 75 - Store a File

158 Programmer’s Guide5 Command ReferenceSet Frequency Step for Customer Scan Channel For Top N Sweep:CHSCanner:EDIT:TOP:CUSTom:STEP <value>:CHS

Strona 76 - Rename A Directory or File

Command Reference 5Programmer’s Guide 159Set Scan Channel For Bottom N Sweep By Signal Standard:CHSCanner:EDIT:BOTTom:STD <value>:CHSCanner:EDIT

Strona 77 - Load Correction File

160 Programmer’s Guide5 Command ReferenceSet Start Frequency For Custom Scan Channel For Bottom N Sweep:CHSCanner:EDIT:BOTTom:CUSTom:STARt <value&g

Strona 78 - Instrument Subsystem

Command Reference 5Programmer’s Guide 161Set Custom Scan Channel Quantity For Bottom N Sweep:CHSCanner:EDIT:BOTTom:CUSTom:CHNumber <value>:CHSCa

Strona 79

Agilent N9342C/43C/44C Handheld Spectrum AnalyzerProgrammer’s Guide92Programming FundamentalsOverview 10Command Categories 12Command Syntax 13Creati

Strona 80 - Sense Subsystem

162 Programmer’s Guide5 Command ReferenceDisplay Threshold State:CHSCanner:DISPlay:THReshold [:STATe] OFF|ON|0|1:CHSCanner:DISPlay:THReshold [:STATe]?

Strona 81 - Frequency Unit

Command Reference 5Programmer’s Guide 163Limit Type:CHSCanner:DISPlay:LIMit:TYPE UPPer|LOWer:CHSCanner:DISPlay:LIMit:TYPE?This command toggles limit t

Strona 82 - Span Channel

164 Programmer’s Guide5 Command ReferenceLogging File Type:CHSCanner:LOG:TYPE CSV|KML:CHSCanner:LOG:TYPE?This command switch the logging file type bet

Strona 83 - Base Band Channel Switch

Command Reference 5Programmer’s Guide 165Demodulation Option SubsystemThe Demodulation Option Subsystem provides you the SCPI command reference for th

Strona 84 - Amplitude Subsection

166 Programmer’s Guide5 Command ReferenceCarrier Frequency Step[:SENSe]:FREQuency:CARRier:STEP <freq>[:SENSe]:FREQuency:CARRier:STEP?This comman

Strona 85 - Scale Type

Command Reference 5Programmer’s Guide 167Preamp[:SENSe]:POWer[:RF]:GAIN[:STATe] OFF|ON|0|1[:SENSe]:POWer[:RF]:GAIN[:STATe]?Use this command to turn on

Strona 86 - Correction Off

168 Programmer’s Guide5 Command ReferenceRestart Meas[:SENSe]:MEASure:RESTartUse this command to restart measurement of current demodulation analysis.

Strona 87 - Read Correction X Data

Command Reference 5Programmer’s Guide 169Read Current AM Modulation Rate:CALCulate:AMA:MRATe?Use this command to query the AM Modulation rate result.E

Strona 88 - PSD Mode State

170 Programmer’s Guide5 Command ReferenceAM Detector PeakHold[:SENSe]:AMA:DEMod:DETector[:FUNCtion]:PEAKhold OFF|ON|0|1[:SENSe]:AMA:DEMod:DETector[:FU

Strona 89 - Bandwidth Subsection

Command Reference 5Programmer’s Guide 171AM Equal Low Pass Filter[:SENSe]:AMA:EQLPfilter AUTO|OFF|IFBW6|IFBW20|IFBW60|IFBW200|IFBW600|IFBW2000[:SENSe]

Strona 90 - Auto Video Bandwidth State

10 Programmer’s Guide2 Programming FundamentalsOverviewThis section is not intended to teach you everything about the SCPI (Standard Commands for Prog

Strona 91 - Trace Subsection

172 Programmer’s Guide5 Command ReferenceAM Depth Upper Limit:CALCulate:AM:LIMit:MDEPth:UPPer <value>:CALCulate:AM:LIMit:MDEPth:UPPer?Use this c

Strona 92 - Trace Format

Command Reference 5Programmer’s Guide 173AM X Scale/DIV:DISPlay:AMA:VIEW:WINDow:TRACe:X[:SCALe]:PDIVi-sion < value >:DISPlay:AMA:VIEW:WINDow:TRA

Strona 93 - Detector Subsection

174 Programmer’s Guide5 Command ReferenceAM X Scale Coupling State:DISPlay:AMA:VIEW:WINDow:TRACe:X[:SCALe]:COUPle 0|1|OFF|ON:DISPlay:AMA:VIEW:WINDow:T

Strona 94 - Average Subsection

Command Reference 5Programmer’s Guide 175AM Y Ref Position:DISPlay:AMA:VIEW:WINDow:TRACe:Y[:SCALe]:RPOSi-tion TOP|CENTer|BOTTom:DISPlay:AMA:VIEW:WINDo

Strona 95 - Sweep Subsection

176 Programmer’s Guide5 Command ReferenceQuery FM Modulation Rate:CALCulate:AMA:MRATe?Use this command to query FM modulation rate measurement result

Strona 96 - Gate View Sweep Time

Command Reference 5Programmer’s Guide 177FM Detector[:SENSe]:AMA:DEMod:DETector[:FUNCtion] PPK|NPK|PNPK|RMS[:SENSe]:AMA:DEMod:DETector[:FUNCtion]?Use

Strona 97 - Gate Source

178 Programmer’s Guide5 Command ReferenceFM Equal Low Pass Filter[:SENSe]:AMA:EQLPfilter AUTO|OFF|IFBW6|IFBW20|IFBW60|IFBW200|IFBW600|IFBW2000[:SENSe]

Strona 98 - Display Subsection

Command Reference 5Programmer’s Guide 179FM Frequency Deviation Upper Limit:CALCulate:FM:LIMit:FDUL:UPPer <freq>:CALCulate:FM:LIMit:FDUL:UPPer?U

Strona 99 - Calculate Subsystem

180 Programmer’s Guide5 Command ReferenceFM X Scale/DIV:DISPlay:AMA:VIEW:WINDow:TRACe:X[:SCALe]:PDIVi-sion <real_time>:DISPlay:AMA:VIEW:WINDow:T

Strona 100 - Query Current Limits Result

Command Reference 5Programmer’s Guide 181FM X Scale Coupling State:DISPlay:AMA:VIEW:WINDow:TRACe:X[:SCALe]:COUPle 0|1|OFF|ON:DISPlay:AMA:VIEW:WINDow:T

Strona 101 - Query Limits Result

Programming Fundamentals 2Programmer’s Guide 11Common Terms used in this BookThe SCPI Consortium or IEEE can provide detailed information on the subje

Strona 102 - Set Limits Margin State

182 Programmer’s Guide5 Command ReferenceFM Y Reference Position:DISPlay:AMA:VIEW:WINDow:TRACe:Y[:SCALe]:RPOSi-tion TOP|CENTer|BOTTom:DISPlay:AMA:VIEW

Strona 103 - Marker Subsection

Command Reference 5Programmer’s Guide 183ASK Average Count[:SENSe]:DMA:AVERage:COUNt <value>[:SENSe]:DMA:AVERage:COUNt?Use this command to speci

Strona 104 - Next Peak Search

184 Programmer’s Guide5 Command ReferenceASK Reference Filter[:SENSe]:DMA:RADio:STANdard:FILTer:REFerence RNYQuist|NYQuist|GAUSsian|NONE[:SENSe]:DMA:R

Strona 105 - Peak Excursion

Command Reference 5Programmer’s Guide 185ASK Measurement Length[:SENSe]:DMA:MEASurement:LENGth <value>[:SENSe]:DMA:MEASurement:LENGth?Use this c

Strona 106 - Peak to Peak Delta Markers

186 Programmer’s Guide5 Command ReferenceASK External Trigger Type:TRIGger:DMA[:SEQuence]:EXTernal:SLOPe POSi-tive|NEGative:TRIGger:DMA[:SEQuence]:EXT

Strona 107 - Marker to Stop Frequency

Command Reference 5Programmer’s Guide 187ASK Carrier Power Upper Limit:CALCulate:DMA:LIMit:POWer:UPPer <value>:CALCulate:DMA:LIMit:POWer:UPPer?U

Strona 108 - Marker Readout X Value

188 Programmer’s Guide5 Command ReferenceASK Carrier Frequency Offset Upper Limit:CALCulate:DMA:LIMit:FOFFset:UPPer <frequency>:CALCulate:DMA:LI

Strona 109 - Marker Demod Delay Time

Command Reference 5Programmer’s Guide 189ASK X Reference ValueDISPlay:DMA:VIEW:WINDow:TRACe:X[:SCALe]:RVALue <integer>:DISPlay:DMA:VIEW:WINDow:T

Strona 110 - Initiate Subsystem

190 Programmer’s Guide5 Command ReferenceASK Y Reference Value:DISPlay:ASK:VIEW:WINDow:TRACe:Y[:SCALe]:RVALue <real>:DISPlay:ASK:VIEW:WINDow:TRA

Strona 111 - Initiate a Single Sweep

Command Reference 5Programmer’s Guide 191ASK Y Scale Coupling State:TRACe[:DATA]?Use this command to query measurement trace data.Example: :DISPlay:DM

Strona 112 - Trigger Subsystem

Notices© Agilent Technologies, Inc. 2012No part of this manual may be reproduced in any form or by any means (including electronic storage and retriev

Strona 113 - RF Burst Level

12 Programmer’s Guide2 Programming FundamentalsCommand CategoriesThe SCPI command falls into two categories: • Subsystem commands that simulate front

Strona 114 - Periodic Timer Offset

192 Programmer’s Guide5 Command ReferenceFSK Symbol Rate[:SENSe]:DMA:RADio:STANdard:SRATe <sps>[:SENSe]:DMA:RADio:STANdard:SRATe?Use this comman

Strona 115 - Synchronization Source

Command Reference 5Programmer’s Guide 193FSK Filter Symbols[:SENSe]:DMA:RADio:STANdard:FILTer:SYMBol < integer >[:SENSe]:DMA:RADio:STANdard:FILT

Strona 116 - Power Measurement Subsystem

194 Programmer’s Guide5 Command ReferenceFSK Trigger Type:TRIGger:DMA[:SEQuence]:SOURce IMMediate|EXTer-nal|RFTRigger:TRIGger:DMA[:SEQuence]:SOURce?Us

Strona 117 - Adjacent Channel Bandwidth

Command Reference 5Programmer’s Guide 195FSK Trigger Delay Time:TRIGger:DMA[:SEQuence]:DELay <time>:TRIGger:DMA[:SEQuence]:DELay?Use this comman

Strona 118 - Channel Space

196 Programmer’s Guide5 Command ReferenceFSK Frequency Deviation Upper Limit:CALCulate:FSK:LIMit:FDEViation:UPPer <fre-quency>:CALCulate:FSK:LIM

Strona 119 - CHP Subsection

Command Reference 5Programmer’s Guide 197FSK View Type:DISPlay:DMA:VIEW WAVeform|SYMBol|EYE|ERRor:DISPlay:DMA:VIEW?Use this command to toggle the diff

Strona 120 - Channel Power Display Mode

198 Programmer’s Guide5 Command ReferenceFSK X Reference Position:DISPlay:DMA:VIEW:WINDow:TRACe:X[:SCALe]:RPOSi-tion LEFT|CENTer|RIGHt:DISPlay:DMA:VIE

Strona 121 - Channel Power Range Bottom

Command Reference 5Programmer’s Guide 199FSK Y Scale/DIVDISPlay:FSK:VIEW:WINDow:TRACe:Y[:SCALe]:PDIVi-sion <real>DISPlay:FSK:VIEW:WINDow:TRACe:Y

Strona 122

200 Programmer’s Guide5 Command ReferenceRead FSK Trace Data:TRACe[:DATA]?Use this command to query FSK measurement trace data.Example: :TRACe?

Strona 123 - OBW Subsection

Command Reference 5Programmer’s Guide 201Power Meter Option SubsystemThe Power Meter Option Subsystem provides you the SCPI command reference for the

Strona 124 - Query OBW and Centroid Result

Programming Fundamentals 2Programmer’s Guide 13Command SyntaxA command consists of mnemonics (keywords), parameters and punctuation. Before you start

Strona 125 - SEM Subsection

202 Programmer’s Guide5 Command ReferenceSwitch Power Range [:SENSe]:POWer:AC:RANGe UPPer|LOWer[:SENSe]:POWer:AC:RANGe?This command toggles the measur

Strona 126 - SEM Total Power Reference

Command Reference 5Programmer’s Guide 203Set Power Meter Reference Power Value[:SENSe]:CORRection:CSET1[:INPut][:MAGNitude] <value>[:SENSe]:CORR

Strona 127 - SEM Marker X

204 Programmer’s Guide5 Command ReferenceSet Power Meter Average Count Number[:SENSe]:AVERage:COUNt <value>[:SENSe]:AVERage:COUNt?This command d

Strona 128 - SEM Offset Resolution BW

Command Reference 5Programmer’s Guide 205Set Power Meter Video Bandwidth Type[:SENSe]:BANDwidth|BWIDth HIGH|MEDium|LOW|OFF[:SENSe]:BANDwidth|BWIDth?Us

Strona 129 - SEM Offset Stop Freq

206 Programmer’s Guide5 Command ReferenceSet Trace X Scale Time:SENSe:TRACe:TIME <value>:SENSe:TRACe:TIME?This command defines the trace X scale

Strona 130 - SEM Offset Abs StartAmpt

Command Reference 5Programmer’s Guide 207Set Gate Length Time[:SENSe]:SWEep[1]:TIME <value>[:SENSe]:SWEep[1]:TIME?This command defines the gate

Strona 131 - SEM Offset Rel StopAmpt

208 Programmer’s Guide5 Command ReferenceSet Bottom Value of Display Range:DISPlay[:WINDow]:DISPrange:BOTTom <value>:DISPlay[:WINDow]:DISPrange:

Strona 132 - SEM Lower Offset Power

Command Reference 5Programmer’s Guide 209Set Chart View to Previous:DISPlay[:WINDow]:CHARt:PREViousThis command set the chart view page to previous pa

Strona 133 - SEM Fail Setting Log

210 Programmer’s Guide5 Command ReferenceSet Limit Lower Value:CALCulate1:LIMit:LOWer[:DATA] <value>:CALCulate1:LIMit:LOWer[:DATA]?This command

Strona 134 - SEM Fail Setting Beep

Command Reference 5Programmer’s Guide 211Set Gate Measurement Type:CALCulate1:FEED1 PEAK|PTAV|AVER|MIN:CALCulate1:FEED1?This command to toggle gate me

Strona 135 - Spec Update Interval

14 Programmer’s Guide2 Programming FundamentalsCommand Statement Rules OverviewBesides the standard notation of SCPI described above, please remember

Strona 136 - Spectrogram Display Frequency

212 Programmer’s Guide5 Command ReferenceSet Trigger Level:TRIGger[:SEQuence]:LEVel <value>:TRIGger[:SEQuence]:LEVel?This command defines the tr

Strona 137 - Spectrogram Marker Time

Command Reference 5Programmer’s Guide 213Power Meter Trigger Holdoff TimeTRIGger[:SEQuence]:HOLDoff <value>TRIGger[:SEQuence]:HOLDoff?This comma

Strona 138

214 Programmer’s Guide5 Command ReferenceTracking Generator Option SubsystemThe Tracking Generator Option Subsystem provides you the SCPI command refe

Strona 139 - Spectrogram Stop Save

Command Reference 5Programmer’s Guide 215Tracking Generator Amplitude Step:SOURce:POWer:STEP[:INCRement] <value> :SOURce:POWer:STEP[:INCRement]?

Strona 140 - Spectrogram Save Stop Time

216 Programmer’s Guide5 Command ReferenceNormalization Reference Position:DISPlay:WINDow:TRACe:Y[:SCALe]:NRPosition <integer>:DISPlay:WINDow:TRA

Strona 141 - Spectrogram Marker Y Value

Programming Fundamentals 2Programmer’s Guide 15Creating Valid CommandsCommands are not case sensitive and there are often many different ways of writi

Strona 142 - CAT Calibration Type

16 Programmer’s Guide2 Programming FundamentalsProgram and Response MessagesTo understand how your instrument and controller communicate using SCPI, y

Strona 143 - CAT Set Cable Type

Programming Fundamentals 2Programmer’s Guide 17Parameters in CommandsThere are four basic types of parameters: boolean, key words, variables and arbit

Strona 144 - CAT Cable Velocity Factor

18 Programmer’s Guide2 Programming FundamentalsVariable Parameters<ampl>,<rel_ampl>The <ampl> (amplitude) parameter and the <rel_

Strona 145 - CAT Stop Frequency

Agilent N9342C/43C/44C Handheld Spectrum AnalyzerProgrammer’s Guide193Status RegistersOverview 20How to use the Status Registers 23Status Register S

Strona 146 - CAT Distance Stop

20 Programmer’s Guide3 Status RegistersOverviewWhen you are programming the instrument you may need to monitor instrument status to check for error co

Strona 147 - CAT Amplitude Auto Scale

Status Registers 3Programmer’s Guide 21Event Register It latches any signal state changes, in the way specified by the filter registers. Bits in the e

Strona 148 - CAT Trace Display Type

Programmer’s Guide In This Guide…This guide contains programming information for the N9342C/43C/44C Handheld Spectrum Analyzer.1 Getting StartedPrepar

Strona 149 - CAT Trace Data Format

22 Programmer’s Guide3 Status RegistersWhat are Status Register SCPI CommandsMost monitoring of the instrument conditions is done at the highest level

Strona 150 - CAT Marker Mode

Status Registers 3Programmer’s Guide 23How to use the Status RegistersA program often needs to detect and manage error conditions or changes in instru

Strona 151 - CAT Query Marker Y axis Value

24 Programmer’s Guide3 Status Registers— The transition registers are preset to register if the condition goes from 0 to 1 (false to true, or a positi

Strona 152 - CAT Limit Beep State

Status Registers 3Programmer’s Guide 25Status Register SystemThe hardware status registers are combined to form the instrument status system. Specific

Strona 153 - CAT Limit State

26 Programmer’s Guide3 Status RegistersThe Status Byte RegisterThe RQS bit is read and reset by a serial poll. The same bit position (MSS) is read, no

Strona 154 - CAT Delete Limit Data

Status Registers 3Programmer’s Guide 27The status byte register contains the following bits:To query the status byte register, send the *STB command.

Strona 155

28 Programmer’s Guide3 Status RegistersStandard Event Status RegisterThe standard event status register is used to determine the specific event that s

Strona 156 - Top N Nu mb er

Status Registers 3Programmer’s Guide 29The standard event status register contains following bits:The standard event status register is used to determ

Strona 157 - Mini Hold State

30 Programmer’s Guide3 Status Registerscommand *ESE 192 (128 + 64). The command *ESE? returns the decimal value of the sum of the bits previously enab

Strona 158 - Average Mode

Agilent N9342C/43C/44C Handheld Spectrum AnalyzerProgrammer’s Guide314b Programming ExampleOverview 32Programming in C using the VTL 33Checking USB

Strona 160 - Top C yc le

32 Programmer’s Guide4 Programming ExampleOverviewThe programming examples in this section keep to the following 3 conventions:• The programming examp

Strona 161 - Scan Start/Stop State Switch

Programming Example 4Programmer’s Guide 33Programming in C using the VTLThis section includes some basic information about programming in the C langua

Strona 162

34 Programmer’s Guide4 Programming ExampleExample ProgramThis example program queries a USB device for an identification string and prints the results

Strona 163 - Delete Channel For List Sweep

Programming Example 4Programmer’s Guide 35viScanf(viN9342C, "%t", &buf);/*Print results */printf("Instrument identification string:

Strona 164

36 Programmer’s Guide4 Programming Example• A device session is used to communicate with a device on an interface. A device session must be opened for

Strona 165

Programming Example 4Programmer’s Guide 37Your program may have several sessions open at the same time by creating multiple session identifiers by cal

Strona 166

38 Programmer’s Guide4 Programming ExampleAddressing a SessionAs seen in the previous section, the rsrcName parameter in the viOpen function is used t

Strona 167 - Standard

Programming Example 4Programmer’s Guide 39Checking the USB ConnectionUsually, using “*IDN?” verifies the data transferring between the controller PC a

Strona 168

40 Programmer’s Guide4 Programming ExampleUsing C with Marker Peak Search and Peak Excursion/*********************************************************

Strona 169 - Display Mode

Programming Example 4Programmer’s Guide 41#include <stdio.h>#include <stdlib.h>#include <math.h>#include <ctype.h>#include <

Strona 170 - Limit Value

Programmer’s GuideContents1 Getting Started 1Remotely Operating the Analyzer 2Computer Requirement for Remote Operation 2Connecting the Analyzer via t

Strona 171 - Logging State

42 Programmer’s Guide4 Programming Example/*Open a USB session.*/viStatus=viOpenDefaultRM(&defaultRM);viStatus=viOpen(defaultRM,"USB0::2391::

Strona 172 - Query Result

Programming Example 4Programmer’s Guide 43/*Set the peak excursion*/viPrintf(viN9342C,"CALC:MARK:PEAK:EXC %1fDB \n",fPeakExcursion);/*Set th

Strona 173 - Demodulation Option Subsystem

44 Programmer’s Guide4 Programming ExampleUsing Marker Delta Mode and Marker Minimum Search/**********************************************************

Strona 174 - Attenuation

Programming Example 4Programmer’s Guide 45#include <stdio.h>#include <stdlib.h>#include <math.h>#include <ctype.h>#include <

Strona 175 - External Gain

46 Programmer’s Guide4 Programming Example{/* Open an USB session*/ viStatus=viOpenDefaultRM(&defaultRM);viStatus=viO-pen(defaultRM,&qu

Strona 176 - AM Demodulation Subsection

Programming Example 4Programmer’s Guide 47/*Set the analyzer to the values given by the user*///viPrintf(viN9342C,"SENS:FREQ:STAR %lf //MHZ;:SENS

Strona 177 - AM Detector

48 Programmer’s Guide4 Programming Example

Strona 178 - AM IF Bandwidth

Agilent N9342C/43C/44C Handheld Spectrum AnalyzerProgrammer’s Guide495Command ReferenceIEEE Common Commands 50System Subsystem 54Memory Subsystem 66

Strona 179 - AM Carrier Power Upper Limit

50 Programmer’s Guide5 Command ReferenceIEEE Common CommandsThe first few pages of this chapter contain common commands specified in IEEE Standard 488

Strona 180 - AM Depth Lower Limit

Command Reference 5Programmer’s Guide 51Standard Event Status Register Query*ESR?Queries and clears the standard event status event register. (This is

Strona 181 - AM X Reference Position

Programmer’s GuideContents5 Command Reference 49IEEE Common Commands 50System Subsystem 54Memory Subsystem 66Instrument Subsystem 70Sense Subsystem 72

Strona 182 - AM Y Scale/DIV

52 Programmer’s Guide5 Command ReferenceReset*RSTThis command presets the instrument to a factory defined condition that is appropriate for remote pro

Strona 183 - FM Demodulation Subsection

Command Reference 5Programmer’s Guide 53Self Test Query*TST?This query is used by some instruments for a self test.Range: Integer, 0 to 255Wait-to-Con

Strona 184 - FM Average Count State

54 Programmer’s Guide5 Command ReferenceSystem SubsystemThis subsystem is used to set the controls and parameters associated with the overall system c

Strona 185 - FM IF Bandwidth

Command Reference 5Programmer’s Guide 55Set System Date:SYSTem:DATE <“yyyymmdd”>:SYSTem:DATE?Sets the system date of the real-time clock of the

Strona 186 - FM Carrier Power Upper Limit

56 Programmer’s Guide5 Command ReferenceEnable Option:SYSTem:LKEY <"option">,<"license key">Use this command to enable

Strona 187 - FM demodulation analysis

Command Reference 5Programmer’s Guide 57Calibrate Time Base by GPS:SYSTem:CALibration:TBASe:GPSUse this command to calibrate the time base by GPS sign

Strona 188 - FM X Reference Position

58 Programmer’s Guide5 Command ReferenceProbe Power:SYSTem:PORT:PROBe OFF|ON|0|1:SYSTem:PORT:PROBe?This command turns on/off the probe power port on t

Strona 189 - FM Y Scale/DIV

Command Reference 5Programmer’s Guide 59Gateway Setting:SYSTem:PORT:IP:GWAY <“xxx.xxx.xxx.xxx”>:SYSTem:PORT:IP:GWAY?Sets the gateway for the ana

Strona 190 - ASK Demodulation Subsection

60 Programmer’s Guide5 Command ReferenceSystem Preset:SYSTem:PRESetUse this command to preset the instrument. The preset type is based on the setting

Strona 191 - ASK Measurement Filter

Command Reference 5Programmer’s Guide 61GPS Information:SYSTem:GPSinfo?This query returns the GPS information. This command is only available with the

Strona 192 - ASK Alpha/BbT

ContentsProgrammer’s GuideAM Demodulation Subsection 168FM Demodulation Subsection 175ASK Demodulation Subsection 182FSK Demodulation Subsection 191Po

Strona 193 - ASK RF Trigger Level

62 Programmer’s Guide5 Command ReferenceTime Power On Date:SYSTem:TIMed:PON:DATE <“YYYMMDD”>:SYSTem:TIMed:PON:DATE?Sets the power on date. This

Strona 194 - ASK Limit State

Command Reference 5Programmer’s Guide 63Time Power Off Date:SYSTem:TIMed:POFF:DATE <“YYYMMDD”>:SYSTem:TIMed:POFF:DATE?Sets the power off date. I

Strona 195 - ASK Depth Lower Limit

64 Programmer’s Guide5 Command ReferenceDC Power In Type:SYSTem:CONFigure:DCPI STANDBY|PWRON:SYSTem:CONFigure:DCPI?This command toggles the DC power i

Strona 196 - ASK X Scale/DIV

Command Reference 5Programmer’s Guide 65Speaker Volume Flag:SYSTem:SPEaker:STATe OFF|ON|0|1:SYSTem:SPEaker:STATe?Use this command to turn on the speak

Strona 197 - ASK X Scale Coupling State

66 Programmer’s Guide5 Command ReferenceMemory SubsystemThe Memory subsystem provides access to mass storage devices such as internal or external disk

Strona 198 - ASK Y Reference Position

Command Reference 5Programmer’s Guide 67Move Data to File:MMEMory:DATA <file_name>,<definite_length_block>:MMEMory:DATA? <file_name>

Strona 199 - FSK Demodulation Subsection

68 Programmer’s Guide5 Command ReferenceStore Peak Table to CSV File:MMEMory:STORe:PEAK <CSV file_name>To store the current peak table as a CSV

Strona 200 - FSK Reference Filter

Command Reference 5Programmer’s Guide 69Load Correction File:MMEMory:LOAD:CORRection ANTenna|CABLe|OTHer|USER, "oldname.cor"This command loa

Strona 201 - FSK Measurement Length

70 Programmer’s Guide5 Command ReferenceInstrument SubsystemThe instrument subsystem includes commands selecting the instrument modes or power measure

Strona 202 - FSK External Trigger Type

Command Reference 5Programmer’s Guide 71SEM - Spectrum Emission MaskCHScanner - Channel ScannerExample: :INSTrument:MEASure CHPowerKey access: MEAS

Strona 204 - Range: -2 MHz to 2 MHz

72 Programmer’s Guide5 Command ReferenceSense SubsystemThe Sense Subsystem provides you the SCPI command reference for normal spectrum analyzer functi

Strona 205 - FSK X Reference Value

Command Reference 5Programmer’s Guide 73Stop Frequency[:SENSe]:FREQuency:STOP <freq>[:SENSe]:FREQuency:STOP?Set the stop frequency of the spectr

Strona 206 - FSK Y Reference Value

74 Programmer’s Guide5 Command ReferenceFrequency Offset[:SENSe]:FREQuency:OFFSet <freq>[:SENSe]:FREQuency:OFFSet?Sets the frequency offset.*RST

Strona 207 - FSK Y Scale Coupling State

Command Reference 5Programmer’s Guide 75Full Frequency Span[:SENSe]:FREQuency:SPAN:FULLSet the frequency span to full scale.*RST: 3.0 GHzExample: :FRE

Strona 208 - Read FSK Trace Data

76 Programmer’s Guide5 Command ReferenceAmplitude SubsectionReference level:DISPlay:WINDow:TRACe:Y[:SCALe]:RLEVel: <value>:DISPlay:WINDow:TRACe:

Strona 209 - Power Meter Option Subsystem

Command Reference 5Programmer’s Guide 77Input Port Preamplifer[:SENSe]:POWer[:RF]:GAIN[:STATe] OFF|ON|0|1[:SENSe]:POWer[:RF]:GAIN[:STATe]?Turns the in

Strona 210 - Set Power Auto Range State

78 Programmer’s Guide5 Command ReferencePower Units of Measure ( Y Axis Unit ):UNIT:POWer DBM|DBMV|DBMVEMF|DBUV|DBU-VEMF|V|W|VEMF:UNIT:POWer?Specifies

Strona 211 - Set Power Meter Average State

Command Reference 5Programmer’s Guide 79Correction Apply State[:SENSe]:CORRection:CSET:ALL[:STATe] OFF|ON|0|1[:SENSe]:CORRection:CSET:ALL[:STATe]?Turn

Strona 212

80 Programmer’s Guide5 Command ReferenceCurrent Correction Select[:SENSe]:CORRection:SELect COR1|COR2|COR3|COR4[:SENSe]:CORRection:SELect?Set current

Strona 213 - Set Trace X Start Time

Command Reference 5Programmer’s Guide 81Bandwidth SubsectionResolution Bandwidth[:SENSe]:BANDwidth|BWIDth[:RESolution] <freq>[:SENSe]:BANDwidth|

Strona 214 - Set Gate Start Time

Agilent N9342C/43C/44C Handheld Spectrum AnalyzerProgrammer’s Guide11Getting StartedThe purpose of this chapter is to serve as a reminder of SCPI (S

Strona 215 - Set Display Auto Range State

82 Programmer’s Guide5 Command ReferenceAuto Video Bandwidth State[:SENSe]:BANDwidth|BWIDth:VIDeo:AUTO OFF|ON|0|1[:SENSe]:BANDwidth|BWIDth:VIDeo:AUTO?

Strona 216 - Set Chart View to End

Command Reference 5Programmer’s Guide 83Trace SubsectionSelect Trace Display Mode:TRACe1|2|3|4:MODE WRITe|MAXHold|MIN-Hold|VIEW|BLANk:TRACe1|2|3|4:MOD

Strona 217 - Set Limit Upper Value

84 Programmer’s Guide5 Command ReferenceSubtract Trace:TRACe:MATH:SUBTract <destination_trace>,<source_trace1>,<source_trace2>This c

Strona 218 - Query Limit Failure Count

Command Reference 5Programmer’s Guide 85Detector SubsectionType of De te ction[:SENSe]:DETector:TRACe[1]|2|3|4[:FUNCtion]NEGa-tive|POSitive|SAMPle|A

Strona 219 - Set Trigger Source

86 Programmer’s Guide5 Command ReferenceAverage SubsectionAverage Type[:SENSe]:AVERage:TYPE LOGPower|POWer|VOLTage[:SENSe]:AVERage:TYPE?Toggle the ave

Strona 220 - Set Trigger Level

Command Reference 5Programmer’s Guide 87Average Restart[:SENSe]:AVERage:TRACe[1]|2|3|4:CLEarRestarts the trace average. This command is only available

Strona 221

88 Programmer’s Guide5 Command ReferenceSweep Mode[:SENSe]:SWEep:MODE AUTO|FFT|SWEep[:SENSe]:SWEep:MODE?Sets the sweep mode manually.*RST: AUTOKey acc

Strona 222

Command Reference 5Programmer’s Guide 89Gate Delay[:SENSe]:SWEep:EGATe:DELay <time> [:SENSe]:SWEep:EGATe:DELay?Set the gate delay time.Example:

Strona 223 - Normalization Reference Level

90 Programmer’s Guide5 Command ReferenceDisplay SubsectionGraticule State:DISPlay:WINDow:TRACe:GRATicule:GRID[:STATe] OFF|ON|0|1:DISPlay:WINDow:TRACe:

Strona 224

Command Reference 5Programmer’s Guide 91Calculate SubsystemThis subsystem is used to perform post-acquisition data processing. In effect, the collecti

Komentarze do niniejszej Instrukcji

Brak uwag