4-7
Programming Commands
Introduction
DELAY
The DELAY command string sets the displayed delay value to the number of
bits specified in the Param variable.
Example
OUTPUT Mta;"PROG:NUMB Param,2.75"
OUTPUT Mta;"PROG:STR Command,DELAY"
OUTPUT Mta;"PROG:WAIT?"
ENTER Mta;A$
OUTPUT Mta;"PROG:STR? Response"
ENTER Mta;Response$
OUTPUT Mta;"PROG:STAT CONT"
DIAGRAM
The DIAGRAM command string sets the diagram display to one of the follow-
ing types specified in the Param variable:
EYE: displays eye pattern. This is the standard display shown on digitizing
oscilloscopes.
EYELINE:
displays a continuous line which shows the actual data value for
the bit period.
PATTERN: displays a continuous line like EYELINE, but for pattern trigger mode.
Values of Program Variables
Variable Data Type Value
Command
string DELAY
Param
floating-point number example: 2.75
Response
string DONE