110 Agilent E6474A User’s Guide
4 Use Your System
Tabl e 4 Signal Generator Downlink Settings
Model Frequency and Power Setting
GSM1900, TDMA, cdma2000, and CDMA
PCS band systems
1959 MHz at -60 dBm
GSM DCS1800 band systems 1843 MHz at -60 dBm
GSM900 band systems 943 MHz at –60 dBm
Cellular CDMA and TDMA band systems 882 MHz at -60 dBm
UMTS E6455C receivers 2140 Mhz at –60 dBm
NOTE
Wait for at least one minute before using the displayed marker value. The
default trace display is set to display a running average of 32. With time,
the marker value will approach the value of the signal generator output.
Figure 47 Spectrum Display with Marker Set to a Center Frequency of 943 MHz (GSM 900 band system)