140 Chapter 4
Programming Command Cross Reference
MANUAL TEST Screens
DC Current Measuring Screens
The following CURRent commands are used to set the controls and parameters
associated with the screens for DC Current measurements and Pass/Fail results.
Table 4-11 CURRent Command Cross Reference
Item Command
DC Current Measurement
[Sync mode]
TESTs:MANual:CURRent:RESults:CAMP?
TESTs:MANual:CURRent:RESults:TALK?
DC Current Measurement
a
TESTs:MANual:CURRent:RESults?
DC Power Voltage TESTs:MANual:CURRent:DCPower:VOLT <real>
TESTs:MANual:CURRent:DCPower:VOLT?
Power Control Level TESTs:MANual:CURRent:PLEVel <int>
TESTs:MANual:CURRent:PLEVel?
Traffic Channel TESTs:MANual:CURRent:CHANnel <int>
TESTs:MANual:CURRent:CHANnel?
Traffic Channel
Frequency
TESTs:MANual:CURRent:FREQuency <real>
TESTs:MANual:CURRent:FREQuency?
a. Neither Camp On nor Talk will not be displayed when the ASYNC or GPRS mode is
selected on the Test Set with Option 002 and/or Option 040.