Chapter 8, Programming the Call Processing Subsystem
CALL BIT Screen Message Field Descriptions
VMAC
This field displays the voice mobile attenuation code. It shows the mobile station’s power
level associated with the designated voice channel.
1 binary character reqired.3
CHAN
Channel number field. Indicates the designated voice channel.
11 binary character required.
Parity
Parity field. The contents of the Parity field cannot be set by the user. The Test Set
calculates the parity bits.