Agilent Technologies N1022A Podręcznik Użytkownika

Przeglądaj online lub pobierz Podręcznik Użytkownika dla Nie Agilent Technologies N1022A. Agilent Technologies N1022A User`s guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 18
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
A
N2790A
Differential Voltage
Probe
User’s Guide
For Safety, Regulatory, and publishing information, see the pages at the back of this book.
© Copyright Agilent Technologies 2009
All Rights Reserved.
Przeglądanie stron 0
1 2 3 4 5 6 ... 17 18

Podsumowanie treści

Strona 1 - Differential Voltage

AN2790A Differential Voltage ProbeUser’s GuideFor Safety, Regulatory, and publishing information, see the pages at the back of this book.© Copyright

Strona 2 - Contents

10Service StrategyService StrategyFor repair, calibration, and to ensure the N2790A performs to its warranted specifications, send the probe to an Ag

Strona 3 - Inspecting the Probe

11Characterization PlotsCharacterization PlotsGraph of dB(Vin), dB(Vout), and dB(Vout/Vin) frequency responseGraph of dB (Vout/Vin) frequency respons

Strona 4

12Calibration Testing ProceduresDerating plot - above 2 MHz, the maximum input operating voltage decreases as the frequency increases.Calibration Tes

Strona 5

13Calibration Testing ProceduresSetup Files for testingTest Gain1 Connect the N2790A probe output to the N1022A adapter. 2 Connect the N1022A adapter

Strona 6

14Calibration Testing ProceduresTest Bandwidth1 Connect the N2790A output to CH1 of the oscilloscope.2 Connect adaptation 2 to the 81150A function ge

Strona 7

15Calibration Test RecordCalibration Test Record Agilent TechnologiesN2790A 100 MHz Differential ProbeSerial No.:_______________________Certification

Strona 8 - Cleaning the Probe

Agilent Technologies P.O. Box 2197 1900 Garden of the Gods Road Colorado Springs, CO 80901Safety NoticesThis apparatus has been designed and tested in

Strona 9 - Using the N2790A Probe

Notices© Agilent Technologies, Inc. 2009No part of this manual may be reproduced in any form or by any means (including elec-tronic storage and retrie

Strona 10 - Service Strategy

AAgilent Technologies Printed in JapanManual Part Number N2790-97000*N2790-97000*

Strona 11 - Frequency (Hz)

2ContentsInspecting the Probe 3Compatibility 4Probe Parts Supplied 5Characteristics and Specifications 6Cleaning the Probe 8Using the N2790A Pro

Strona 12 - Frequency

3Inspecting the ProbeInspecting the Probe❏ Inspect the shipping container for damage. Keep a damaged shipping container or cushioning material until

Strona 13

4Inspecting the ProbeN2790A Differential Voltage ProbeThe N2790A differential probe allows you to safely measure high-voltage floating circuits with

Strona 14

5Inspecting the ProbeProbe Parts SuppliedThe following diagram and table show the parts supplied with the N2790A Probe. The probe tips you receive ma

Strona 15 - Agilent Technologies

6Characteristics and SpecificationsCharacteristics and SpecificationsCharacteristics and specifications for the N2790A Differential Voltage Probe are

Strona 16

7Characteristics and SpecificationsOutput Characteristics Environmental Specifications Safety SpecificationsOutput cable Safety designed BNC cableMax

Strona 17

8Cleaning the ProbeWARNING SHOCK HAZARD!These probes are designed for use with oscilloscopes that have a common terminal at GROUND POTENTIAL (in acco

Strona 18 - *N2790-97000*

9Using the N2790A ProbeUsing the N2790A ProbePowering the N2790AThe N2790A probe is powered by the autoprobe interface found on Agilent InfiniiVision

Komentarze do niniejszej Instrukcji

Brak uwag