© Agilent Technologies2000–2003 Agilent 3070 / 79000 DUT Power Supply Installation 59
Connecting the DUT Power Supply Cables
Connecting the Overvoltage Shutdown Cables
This section describes how to connect the overvoltage
shutdown cables for 6624A and 6621A DUT Power
Supplies. (The 6634A/B and 6642A do not have
overvoltage shutdown terminals.)
Each output of the 6624A and the 6621A power
supplies has two overvoltage terminals. These terminals
are labeled
+OV and -OV. By connecting the overvoltage
terminals in parallel, an overvoltage shutdown on any
one output will trigger an overvoltage shutdown on the
remaining outputs. Each 44940A (6624A) includes 4
cables (03066-61622) for this purpose. Each 44941A
(6621A) includes 2 cables (03066-61622). Use the
guidelines below to connect the overvoltage cables.
In all cases, ensure that the brown wire is
connected to the +OV terminal and the white wire
is connected to the -OV terminal.
On each supply, connect the overvoltage terminals
for output 1 to the overvoltage terminals of output
2.
On each 6624A supply, connect the overvoltage
terminals for output 3 to the overvoltage terminals
for output 4.
Interconnect (chain) the overvoltage terminals for
output 2 of each 6624A connected to ASRU ports
1 through 4.
Interconnect (chain) the overvoltage terminals for
output 2 of each 6624A connected to ASRU ports
5 and 6. Do not interconnect the chains for
supplies connected to ASRU ports 1 through 4
and supplies connected to ASRU ports 5 and 6.
Interconnect (chain) the overvoltage terminals for
output 3 of each 6624A connected to ASRU ports
1 through 4. Do not interconnect the chains for
output 3 and output 2.
Interconnect (chain) the overvoltage terminals for
output 3 of each 6624A connected to ASRU ports
5 and 6. Do not interconnect the chains for
supplies connected to ASRU ports 1 through 4
and supplies connected to ASRU ports 5 and 6
and do not interconnect the chains for output 3
and output 2.
Interconnect (chain) the overvoltage terminals for
output 2 of each 6621A connected to ASRU ports
1 through 4.
Interconnect (chain) the overvoltage terminals for
output 2 of each 6621A connected to ASRU ports
5 and 6. Do not interconnect the chains for
supplies connected to ASRU ports 1 through 4
and supplies connected to ASRU ports 5 and 6.
Do not interconnect chains of different supply
types.
Connect extra cables in parallel on the back of
supplies, so they are available if more supplies are
added in the future.
Figure 28 on page 61 through Figure 35 on page 68
illustrate examples of how to connect the overvoltage
terminals using 6624A, 6621A, and 6634A/B supplies.
Figure 35 on page 68 illustrates how to connect the
terminals using four 6624A supplies connected to ports
1 though 4 in four modules and two 6621A supplies
connected to ports 5 and 6. The overvoltage cable
Przeglądanie stron 61