Test Details: Screen Shots and Discussion
October 29, 2012
Confidentiality Label
28
Pre Emphasis Tests
Notes:
1. The nominal settings of Level 0, 1, 2, 3 are 0, 3.5, 6, and 9.5 dB BUT we really don’t care
about the absolute level. What is important is the DIFFERENCE between settings.
2. We measure the Pre-Emphasis between adjacent pre-emphasis settings at a specific Level
setting and compare.
3. The non transition voltages are also checked: V
Nontran_low
/V
Nontran_high
> 0.7
PE 0 to PE1 Resultant =
20*Log [(210/179)
/(135/192)]
= 4.45 dB
Non Transition Voltages=
179/192 = .93
Level Setting 0, PE setting 1
Level Setting 0, PE setting 0