12
87050A Option H test sets
1
Designed to work with the 875x series of network analyzers.
Frequency range: 30 kHz to 6 GHz Switch type: Mechanical
2
Connectors: Type-N (f) Switching speed: 60 ms
Impedance: 50 ohm I/O control: GPIB and Parallel
Option Designed for:
3
Ports Raw (uncorrected) Raw (uncorrected) Test set type
(Works with:) return loss insertion loss
H06
875x
6
≥ 25 dB, 30 kHz to 1.3 GHz ≤ 1 dB, 30 kHz to 1.3 GHz
H12
(871x)
12
≥ 16 dB, 1.3 to 3.0 GHz ≤ 1.75 dB, 1.3 to 3.0 GHz
Full crossbar
H16
(PNA)
16
≥ 12 dB, 3.0 to 6.0 GHz ≤ 2.5 dB, 3.0 to 6.0 GHz
H24 24
87050A Option K test sets
1
Designed to work with the 872x series of network analyzers.
Frequency range: 50 MHz to 20 GHz Switch type: Mechanical
2
Connectors: 3.5 mm (f) Switching speed: 60 ms
Impedance: 50 ohm I/O control: GPIB and Parallel
Option Designed for:
3
Ports Raw (uncorrected) Raw (uncorrected) Test set type
(Works with:) return loss insertion loss
K06
872x
6 ≥ 24 dB, 50 MHz to 1.3 GHz ≤ 2.5 dB, 50 MHz to 6.0 GHz
Full crossbar
K12
(875x)
12 ≥ 20 dB, 1.3 to 3.0 GHz ≤ 3.5 dB, 60 to 12.4 GHz
K16
(PNA)
16 ≥ 14 dB, 3.0 to 6.0 GHz ≤ 4.5 dB, 12.4 to 20 GHz
K22 22 ≥ 12 dB, 6.0 to 12.4 GHz SCMM
4
K24 24 ≥ 8 dB, 12.4 to 20 GHz Full crossbar
1 The 87050A family of test sets do not include control interface. Contact your local Agilent Field Engineer for hardware and software control
integration solutions.
2 Life time of mechanical switches are specified at 5 million cycles
3 Designed for/(Works with:) Test sets that are used with analyzers other then the ones that they are designed for may require extra cabling or custom designed
software controls. See data sheets for particular details.
4 Single connection multiple measurements test set