Set Up Your System 3
Agilent E6474A User’s Guide 35
Mounting the Hub
1 Rotate the locking knobs horizontally to allow devices to
slide into the slots of the chassis.
2 Insert the Hub into the top slot of the chassis.
3 If equipped, insert the Agilent direct connect GPS/DR or a
second direct connect Hub into the bottom slot of the chassis.
4 Rotate the locking knobs to a vertical position, and tighten
the screws.
Mounting the Hub and Scanner or Receiver
1 If you currently have the Direct Connect Hub in the carry
pack for indoor testing, remove the Direct Connect Hub from
the metal chassis that houses the battery..
2 If equipped, attach the E645xx Receiver(s) to the receiver
mounting plate with the straps provided.
Figure 1 Connecting the phone via a PCMCIA card