3 DC Power Supply Operation
Protection Functions
94 U3606B User’s Guide
Over-voltage limit (OV)
The over- voltage limit prevents the output voltage present
across the load to change beyond the programmed
over- voltage limit. If the load effect exceeds the programmed
over- voltage limit, the CC output will be lowered to maintain
the output power across the load. The combination of the OV
and OVP features create a closed loop circuit protection for
sensitive load behaviors.
Select the constant current function
1
The CC annunciator will turn on according to your selection.
2