Agilent TechnologiesAgilent U3606B Multimeter|DC Power SupplyUser’s GuideU3606-90054_UG_EN.book Page I Friday, July 11, 2014 5:12 PM

Strona 2

X U3606B User’s GuideMeasuring Frequency/Pulse Width/Duty Cycle (Current Path) 56Selecting a Range 59Setting the Resolution 61Math Oper

Strona 3 - Safety Symbols

3 DC Power Supply Operation Constant Current Operation84 U3606B User’s GuideSelect the constant current functionAdjust the constant current value5LOA

Strona 4 - Safety Considerations

DC Power Supply Operation 3 Constant Current OperationU3606B User’s Guide 85Enable the output8NOTE• The output current is limited by the range selecte

Strona 5 - Environmental Conditions

3 DC Power Supply Operation Protection Functions86 U3606B User’s GuideProtection FunctionsOver-voltage protection (OVP)In constant current mode, the

Strona 6 - Regulatory Markings

DC Power Supply Operation 3 Protection FunctionsU3606B User’s Guide 87Select the OVP functionAdjust the OVP value and save the changes43The OVP annunc

Strona 7

3 DC Power Supply Operation Protection Functions88 U3606B User’s GuideChecking the OVP operationTo check OVP operation, raise the regulated output cu

Strona 8

DC Power Supply Operation 3 Protection FunctionsU3606B User’s Guide 89This will disable the U3606B output, cause the CC annunciator to flash, and the

Strona 9 - Table of Contents

3 DC Power Supply Operation Protection Functions90 U3606B User’s GuideOver-current protection (OCP)In constant voltage mode, the U3606B regulates the

Strona 10 - 3 DC Power Supply Operation

DC Power Supply Operation 3 Protection FunctionsU3606B User’s Guide 91Select the OCP functionAdjust the OCP value and save the changes43The OVP annunc

Strona 11 - 4 System-Related Operation

3 DC Power Supply Operation Protection Functions92 U3606B User’s GuideChecking the OCP operationTo check OCP operation, raise the regulated output cu

Strona 12 - 6 List of Error Messages

DC Power Supply Operation 3 Protection FunctionsU3606B User’s Guide 93This will disable the U3606B output, cause the CC annunciator to flash, and the

Strona 13 - List of Figures

U3606B User’s Guide XI4 System-Related OperationUsing the Utility Menu 124Utility Menu Summary 126Utility Menu Items 129Reading error m

Strona 14 - XIV U3606B User’s Guide

3 DC Power Supply Operation Protection Functions94 U3606B User’s GuideOver-voltage limit (OV)The over- voltage limit prevents the output voltage pres

Strona 15 - List of Tables

DC Power Supply Operation 3 Protection FunctionsU3606B User’s Guide 95Select the OV functionAdjust the OV value and save the changes43The OV annunciat

Strona 16 - XVI U3606B User’s Guide

3 DC Power Supply Operation Protection Functions96 U3606B User’s GuideNOTE• After adjusting the OV value, you can also press [Limit] again to save th

Strona 17 - Introduction

DC Power Supply Operation 3 Protection FunctionsU3606B User’s Guide 97Over-current limit (OC)The over- current limit prevents the output current flowi

Strona 18 - About This Manual

3 DC Power Supply Operation Protection Functions98 U3606B User’s GuideSelect the OC functionAdjust the OC value and save the changes43The OC annuncia

Strona 19 - Preparing the U3606B

DC Power Supply Operation 3 Protection FunctionsU3606B User’s Guide 99NOTE• After adjusting the OC value, you can also press [Limit] again to save the

Strona 20 - 4 U3606B User’s Guide

3 DC Power Supply Operation Square-Wave Operation100 U3606B User’s GuideSquare-Wave OperationThe square- wave function is a unique function for many

Strona 21

DC Power Supply Operation 3 Square-Wave OperationU3606B User’s Guide 101Select the square wave functionView the amplitude, duty cycle, and pulse width

Strona 22

3 DC Power Supply Operation Square-Wave Operation102 U3606B User’s GuideEnable the output7U3606-90054_UG_EN.book Page 102 Friday, July 11, 2014 5:

Strona 23 - Adjust the carry handle

DC Power Supply Operation 3 Square-Wave OperationU3606B User’s Guide 103Adjust the amplitude, duty cycle, and pulse width valuesAdjust the amplitude v

Strona 24 - Rack mount the instrument

XII U3606B User’s GuideDigital Multimeter Specifications 158Specification assumptions 158DC specifications 159AC specifications 16

Strona 25 - U3606B User’s Guide 9

3 DC Power Supply Operation Square-Wave Operation104 U3606B User’s GuideAdjust the frequency, duty cycle, or pulse width values and save the changesU

Strona 26 - Stack multiple U3606B units

DC Power Supply Operation 3 Square-Wave OperationU3606B User’s Guide 105Table 3 - 5 Square-wave amplitude minimum and maximum valuesRangeSquare wave a

Strona 27 - The U3606B in Brief

3 DC Power Supply Operation Sweep Functions106 U3606B User’s GuideSweep FunctionsThe U3606B is equipped with ramp and scan capability. Use the ramp f

Strona 28 - Overview

DC Power Supply Operation 3 Sweep FunctionsU3606B User’s Guide 107Connect the load1LOAD32U3606-90054_UG_EN.book Page 107 Friday, July 11, 2014 5:12

Strona 29 - Rear panel

3 DC Power Supply Operation Sweep Functions108 U3606B User’s GuideSelect the constant voltage or constant current functionSelect the ramp function an

Strona 30 - 14 U3606B User’s Guide

DC Power Supply Operation 3 Sweep FunctionsU3606B User’s Guide 109Scan signalA typical scan signal length is based on the following parameters:• the a

Strona 31 - Display screen

3 DC Power Supply Operation Sweep Functions110 U3606B User’s GuideThe total dwell time will increase with respect to the number of steps and the scan

Strona 32 - 16 U3606B User’s Guide

DC Power Supply Operation 3 Sweep FunctionsU3606B User’s Guide 111Select the constant voltage or constant current functionSelect the scan function and

Strona 33 - U3606B User’s Guide 17

3 DC Power Supply Operation Sweep Functions112 U3606B User’s GuideNOTE• The scan dwell time also affects the first step at amplitude 0. An initial de

Strona 34

DC Power Supply Operation 3 Selecting a RangeU3606B User’s Guide 113Selecting a RangeYou can allow the U3606B to automatically select the range using

Strona 35 - Using the Shift key

U3606B User’s Guide XIIIList of FiguresFigure 1-1 Single rack mounted U3606B 8Figure 1-2 Two U3606B rack mounted side-by-side 8Figure 1-3 Rac

Strona 36 - 20 U3606B User’s Guide

3 DC Power Supply Operation Enabling the Output114 U3606B User’s GuideEnabling the OutputPress [] to turn the U3606B output on or off.With the outpu

Strona 37 - U3606B User’s Guide 21

DC Power Supply Operation 3 Remote SensingU3606B User’s Guide 115Remote SensingRemote sensing is used to maintain regulation at the load and reduce de

Strona 38 - 22 U3606B User’s Guide

3 DC Power Supply Operation Remote Sensing116 U3606B User’s GuideRemote sensing connectionsRemote sensing requires connecting the load leads from the

Strona 39 - U3606B User’s Guide 23

DC Power Supply Operation 3 Remote SensingU3606B User’s Guide 117Connecting the load leads to the rear terminal block1 Turn off the power. Remove all

Strona 40 - Input/Output terminals

3 DC Power Supply Operation Remote Sensing118 U3606B User’s Guide4 Loosen the top screws with a slotted screw driver and connect the rear output term

Strona 41 - U3606B User’s Guide 25

DC Power Supply Operation 3 Remote SensingU3606B User’s Guide 119Do not loosen the top screws of the rear output terminal block at a tilted angled.CAU

Strona 42 - 26 U3606B User’s Guide

3 DC Power Supply Operation Remote Sensing120 U3606B User’s GuideEnable remote sensingTo configure the U3606B for remote sensing:1 Turn off the U3606

Strona 43 - U3606B User’s Guide 27

DC Power Supply Operation 3 Remote SensingU3606B User’s Guide 121StabilityUsing remote sensing under certain combinations of load lead lengths and lar

Strona 44 - 28 U3606B User’s Guide

3 DC Power Supply Operation Remote Sensing122 U3606B User’s GuideWith remote sensing, any voltage dropped in the load leads must be added to the load

Strona 45 - Operation and Features

123U3606B Multimeter|DC Power SupplyUser’s GuideAgilent Technologies4System-Related OperationUsing the Utility Menu 124Utility Menu Summary 126U

Strona 46 - Measuring Voltage

XIV U3606B User’s GuideTHIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.U3606-90054_UG_EN.book Page XIV Friday, July 11, 2014 5:12 PM

Strona 47 - Voltage measurement summary

4 System-Related Operation Using the Utility Menu124 U3606B User’s GuideUsing the Utility MenuThe Utility menu allows you to customize a number of no

Strona 48 - Using the AC+DC function

System-Related Operation 4 Using the Utility MenuU3606B User’s Guide 125Press [Shift] > [Utility] to enter the Utility menu. The first menu item al

Strona 49 - Measuring Current

4 System-Related Operation Utility Menu Summary126 U3606B User’s GuideUtility Menu SummaryThe Utility menu items are summarized in the table below. F

Strona 50 - Current measurement summary

System-Related Operation 4 Utility Menu SummaryU3606B User’s Guide 127SMothoF onSelect “oF” to disable the smooth function, or “on” to enable the smoo

Strona 51

4 System-Related Operation Utility Menu Summary128 U3606B User’s Guidedb.rEF NNNN ΩSet dB reference impedance value from 1 Ω to 9999 Ω.page 142SELF.t

Strona 52 - Measuring Resistance

System-Related Operation 4 Utility Menu ItemsU3606B User’s Guide 129Utility Menu ItemsReading error messagesIf there are no errors in the error queue,

Strona 53 - U3606B User’s Guide 37

4 System-Related Operation Utility Menu Items130 U3606B User’s GuidePress [] again to read the remaining errors. The error queue is automatically cl

Strona 54 - 38 U3606B User’s Guide

System-Related Operation 4 Utility Menu ItemsU3606B User’s Guide 131Recording measurement data (data logging)Press [] or [] to switch between “StoP”,

Strona 55 - Test ing Conti nuity

4 System-Related Operation Utility Menu Items132 U3606B User’s GuideEnabling refresh holdPress [] or [] to change the refresh hold variation (001% t

Strona 56 - Test current

System-Related Operation 4 Utility Menu ItemsU3606B User’s Guide 133Setting the smooth functionThe smooth function is a special short- term average th

Strona 57 - Continuity test summary

U3606B User’s Guide XVList of TablesTable 1-1 Front panel descriptions 12Table 1-2 Rear panel descriptions 14Table 1-3 VFD display descriptio

Strona 58 - Measuring Low-Resistance

4 System-Related Operation Utility Menu Items134 U3606B User’s GuideTo set the fluctuation count, press [] until the cursor position is on the fluctu

Strona 59 - U3606B User’s Guide 43

System-Related Operation 4 Utility Menu ItemsU3606B User’s Guide 135To set the number of points, press [] until the cursor position is on the number o

Strona 60

4 System-Related Operation Utility Menu Items136 U3606B User’s GuideConfiguring the scan signal parametersPress [Voltage] or [Current] if you wish t

Strona 61 - U3606B User’s Guide 45

System-Related Operation 4 Utility Menu ItemsU3606B User’s Guide 137Press [] or [] to change the scan signal amplitude end position.Press [] or [] u

Strona 62 - 46 U3606B User’s Guide

4 System-Related Operation Utility Menu Items138 U3606B User’s GuideConfiguring the ramp signal parametersPress [Voltage] or [Current] if you wish t

Strona 63 - Measuring Capacitance

System-Related Operation 4 Utility Menu ItemsU3606B User’s Guide 139Press [] or [] to change the ramp signal amplitude end position.Press [] or [] u

Strona 64 - 48 U3606B User’s Guide

4 System-Related Operation Utility Menu Items140 U3606B User’s GuideSetting the output protection stateThe OVP and OCP features depend on the output

Strona 65 - Measuring tips

System-Related Operation 4 Utility Menu ItemsU3606B User’s Guide 141Press [] or [] to switch between “YES” and “no”. Select “YES” to enable the outpu

Strona 66 - Test ing Diodes

4 System-Related Operation Utility Menu Items142 U3606B User’s GuideSelecting a dBm reference resistance valueThe dBm function is logarithmic, and is

Strona 67 - U3606B User’s Guide 51

System-Related Operation 4 Utility Menu ItemsU3606B User’s Guide 143Press [] or [] to select “YES” and then press [Shift] > [Save] to save. The in

Strona 68 - Testi ng ti ps

XVI U3606B User’s Guideof range) 165Table 5-4 Frequency sensitivity for voltage measurement 166Table 5-5 Frequency sensitivity for current mea

Strona 69 - Connect the test leads

4 System-Related Operation Utility Menu Items144 U3606B User’s GuideConfiguring the beeperNormally, the U3606B beeps whenever certain conditions are

Strona 70

System-Related Operation 4 Utility Menu ItemsU3606B User’s Guide 145Changing the power-on stateThe following procedure shows you how to enable or disa

Strona 71 - U3606B User’s Guide 55

4 System-Related Operation Utility Menu Items146 U3606B User’s GuideAdjusting the display brightnessPress [] or [] to cycle between the available br

Strona 72

System-Related Operation 4 Storing and Recalling Instrument StatesU3606B User’s Guide 147Storing and Recalling Instrument StatesYou can save and recal

Strona 73

4 System-Related Operation Storing and Recalling Instrument States148 U3606B User’s GuideStoring a stateTo store an instrument stateUse the arrow key

Strona 74 - 58 U3606B User’s Guide

System-Related Operation 4 Storing and Recalling Instrument StatesU3606B User’s Guide 149Recalling a stored stateTo recall an instrument stateUse the

Strona 75

4 System-Related Operation Remote Operation150 U3606B User’s GuideRemote OperationThe U3606B is shipped with both a GPIB (IEEE- 488) interface and a

Strona 76

System-Related Operation 4 Remote OperationU3606B User’s Guide 151Configuring and connecting the GPIB interfaceThe GPIB (IEEE- 488) connector on the r

Strona 77 - Setting the Resolution

4 System-Related Operation Remote Operation152 U3606B User’s GuideConfiguring and connecting the USB interfaceSelect the appropriate USB class for co

Strona 78 - Math Operations

System-Related Operation 4 Remote OperationU3606B User’s Guide 153SCPI language versionYou can determine the SCPI language version of the instrument b

Strona 79

1U3606B Multimeter|DC Power SupplyUser’s GuideAgilent Technologies1IntroductionAbout This Manual 2Documentation map 2Safety notes 2Preparing

Strona 80 - Enable the null function

4 System-Related Operation Remote Operation154 U3606B User’s GuideTHIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.U3606-90054_UG_EN.book Page 154 Frida

Strona 81 - Edit the null value

155U3606B Multimeter|DC Power SupplyUser’s GuideAgilent Technologies5Characteristics and SpecificationsProduct Characteristics 156Digital Multimete

Strona 82 - Enable the dBm function

5 Characteristics and Specifications Product Characteristics156 U3606B User’s GuideProduct CharacteristicsPOWER SUPPLY• Universal 100 Vac to 240 Vac

Strona 83 - Enable the dB function

Characteristics and Specifications 5 Product CharacteristicsU3606B User’s Guide 157WARRANTY• Please refer to http://www.agilent.com/go/warranty_terms•

Strona 84 - Edit the relative value

5 Characteristics and Specifications Digital Multimeter Specifications158 U3606B User’s GuideDigital Multimeter SpecificationsSpecification assumptio

Strona 85 - Enable the MinMax function

Characteristics and Specifications 5 Digital Multimeter SpecificationsU3606B User’s Guide 159DC specificationsTable 5 - 1 DC accuracy specifications ±

Strona 86 - *RST command)

5 Characteristics and Specifications Digital Multimeter Specifications160 U3606B User’s GuideResistance[4]100.000 Ω 1 mΩ 0.83 mA 0.04 + 0.008 0.04 +

Strona 87 - Enable the Limit function

Characteristics and Specifications 5 Digital Multimeter SpecificationsU3606B User’s Guide 161Capacitance[7]1.000 nF 0.001 nF0.75 µA current source- -

Strona 88 - 72 U3606B User’s Guide

5 Characteristics and Specifications Digital Multimeter Specifications162 U3606B User’s Guide[5] Specifications stated are for 4-wire low-resistance

Strona 89

Characteristics and Specifications 5 Digital Multimeter SpecificationsU3606B User’s Guide 163AC specificationsAC accuracy specificationsTable 5 - 2 AC

Strona 90 - Enable the Hold function

1 Introduction About This Manual2 U3606B User’s GuideAbout This ManualThe descriptions and instructions in this manual apply to the Agilent U3606B Mu

Strona 91 - Triggering the Multimeter

5 Characteristics and Specifications Digital Multimeter Specifications164 U3606B User’s Guide[8] For 750 V range: the accuracy is specified for input

Strona 92 - Front panel triggering

Characteristics and Specifications 5 Digital Multimeter SpecificationsU3606B User’s Guide 165Frequency specificationsTable 5 - 3 Frequency accuracy sp

Strona 93 - Remote interface triggering

5 Characteristics and Specifications Digital Multimeter Specifications166 U3606B User’s GuideTable 5 - 4 Frequency sensitivity for voltage measuremen

Strona 94

Characteristics and Specifications 5 Digital Multimeter SpecificationsU3606B User’s Guide 167Duty cycle and pulse width specificationsOperating specif

Strona 95 - DC Power Supply Operation

5 Characteristics and Specifications Digital Multimeter Specifications168 U3606B User’s GuideAC +DC current(1A at 1 kHz)Slow (5½ digit) 4 2.9 2.9Fast

Strona 96 - Constant Voltage Operation

Characteristics and Specifications 5 Digital Multimeter SpecificationsU3606B User’s Guide 169Supplemental characteristicsWARNINGExceeding the crest fa

Strona 97 - U3606B User’s Guide 81

5 Characteristics and Specifications Digital Multimeter Specifications170 U3606B User’s GuideInput protection: 750 Vrms on all rangesCrest factor: Fo

Strona 98

Characteristics and Specifications 5 Digital Multimeter SpecificationsU3606B User’s Guide 171ResistanceMeasurement method: Two-wire, open-circuit volt

Strona 99

5 Characteristics and Specifications Digital Multimeter Specifications172 U3606B User’s GuideCapacitanceMeasurement method: Computed from constant cu

Strona 100 - 84 U3606B User’s Guide

Characteristics and Specifications 5 DC Power Supply SpecificationsU3606B User’s Guide 173DC Power Supply SpecificationsSafety considerationsThe U3606

Strona 101 - Enable the output

Introduction 1 Preparing the U3606BU3606B User’s Guide 3Preparing the U3606BCheck the shipmentWhen you receive your instrument, check the shipment acc

Strona 102 - Protection Functions

5 Characteristics and Specifications DC Power Supply Specifications174 U3606B User’s GuidePerformance specificationsTable 5 - 8 DC power supply perfo

Strona 103 - Select the OVP function

Characteristics and Specifications 5 DC Power Supply SpecificationsU3606B User’s Guide 175Programming resolutionVoltage 1 mV 1 mV 1 mV 1 mV 0.1 mVCurr

Strona 104 - Checking the OVP operation

5 Characteristics and Specifications DC Power Supply Specifications176 U3606B User’s GuideSupplemental characteristicsTable 5 - 9 DC power supply sup

Strona 105 - Resetting the OVP condition

Characteristics and Specifications 5 DC Power Supply SpecificationsU3606B User’s Guide 177Square-wave output characteristicsTable 5-10 Square-wave out

Strona 106 - Over-current protection (OCP)

5 Characteristics and Specifications DC Power Supply Specifications178 U3606B User’s Guide[2] For frequency signals greater than 100 Hz, an additiona

Strona 107 - Select the OCP function

Characteristics and Specifications 5 DC Power Supply SpecificationsU3606B User’s Guide 179Sweep characteristicsTable 5-11 Scan output characteristicsS

Strona 108 - Checking the OCP operation

5 Characteristics and Specifications DC Power Supply Specifications180 U3606B User’s GuideTHIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.U3606-90054_UG_

Strona 109 - Resetting the OCP condition

181U3606B Multimeter|DC Power SupplyUser’s GuideAgilent Technologies6List of Error MessagesError Messages 182Command errors 183Execution errors

Strona 110 - Over-voltage limit (OV)

6 List of Error Messages Error Messages182 U3606B User’s GuideError MessagesError messages are created once an erroneous condition is detected.Errors

Strona 111 - Select the OV function

List of Error Messages 6 Error MessagesU3606B User’s Guide 183Command errorsThe following table shows the list of command errors. These errors set the

Strona 112

II U3606B User’s GuideNotices© Agilent Technologies, Inc. 2013–2014No part of this manual may be reproduced in any form or by any means (including ele

Strona 113 - Over-current limit (OC)

1 Introduction Preparing the U3606B4 U3606B User’s GuidePower cordU8201A combo test lead kitUSB Standard-A to Type-B interface cableCertificate of Ca

Strona 114 - Select the OC function

6 List of Error Messages Error Messages184 U3606B User’s GuideExecution errorsThe following table shows the list of execution errors. These errors se

Strona 115

List of Error Messages 6 Error MessagesU3606B User’s Guide 185Internal errorsThe following table shows the list of internal errors.Query errorsThe fol

Strona 116 - Square-Wave Operation

6 List of Error Messages Error Messages186 U3606B User’s GuideSelf-test errorsThe following errors indicate failures that may occur during a self- te

Strona 117 - U3606B User’s Guide 101

List of Error Messages 6 Error MessagesU3606B User’s Guide 187Calibration errorsThe following errors indicate failures that may occur during a calibra

Strona 118

6 List of Error Messages Error Messages188 U3606B User’s Guide723 Cal CAP offset out of range726 Cal RES open out of range742 Cal checksum failed, DC

Strona 119 - U3606B User’s Guide 103

© Agilent Technologies, Inc. 2013–2014Second Edition, July 3, 2014U3606-90054www.agilent.comAgilent TechnologiesContact usTo obtain service, warranty,

Strona 120

Introduction 1 Preparing the U3606BU3606B User’s Guide 5Connect power to the instrumentNOTEThe U3606B is shipped from the factory with a power-line co

Strona 121

1 Introduction Preparing the U3606B6 U3606B User’s GuideNOTE• For subsequent power cycles, the U3606B returns to the last power-off state by default.

Strona 122 - Sweep Functions

Introduction 1 Preparing the U3606BU3606B User’s Guide 7Adjust the carry handle12a32bU3606-90054_UG_EN.book Page 7 Friday, July 11, 2014 5:12 PM

Strona 123 - Connect the load

1 Introduction Preparing the U3606B8 U3606B User’s GuideRack mount the instrumentYou can mount the U3606B in a standard 19- inch rack cabinet using o

Strona 124 - 108 U3606B User’s Guide

Introduction 1 Preparing the U3606BU3606B User’s Guide 9Figure 1-3 Rack mount dimensionsU3606-90054_UG_EN.book Page 9 Friday, July 11, 2014 5:12 PM

Strona 125 - Scan signal

1 Introduction Preparing the U3606B10 U3606B User’s GuideStack multiple U3606B unitsYou may stack multiple U3606B units on top of each other. The rub

Strona 126

Introduction 1 The U3606B in BriefU3606B User’s Guide 11The U3606B in BriefDimensionsFigure 1-4 U3606B dimensions105 mm334 mm226 mmU3606-90054_UG_EN.b

Strona 127 - U3606B User’s Guide 111

1 Introduction The U3606B in Brief12 U3606B User’s GuideOverviewFront panelThe front panel parts of the U3606B are described in this section.Figure 1

Strona 128

Introduction 1 The U3606B in BriefU3606B User’s Guide 13Rear panelThe rear panel parts of the U3606B are described in this section.Figure 1-6 The rear

Strona 129 - Selecting a Range

U3606B User’s Guide IIISafety SymbolsThe following symbols on the instrument and in the documentation indicate precautions which must be taken to main

Strona 130 - Enabling the Output

1 Introduction The U3606B in Brief14 U3606B User’s GuideTable 1 - 2 Rear panel descriptionsLegend Description1 AC inlet Connects the AC power line —

Strona 131 - Remote Sensing

Introduction 1 The U3606B in BriefU3606B User’s Guide 15Display screenThe display annunciators of the U3606B are described in this section.Figure 1-7

Strona 132 - +S + + – – –S

1 Introduction The U3606B in Brief16 U3606B User’s Guide2EXT Remote sensing operation enabledCC Constant current operation selectedCV Constant voltag

Strona 133

Introduction 1 The U3606B in BriefU3606B User’s Guide 176LOG Data logging in progressStore Store instrument state selectedRecall Recall instrument sta

Strona 134

1 Introduction The U3606B in Brief18 U3606B User’s GuideKeypadFigure 1-8 The keypad at a glance11ms Pulse width unit for square-wave output% Duty cyc

Strona 135 - U3606B User’s Guide 119

Introduction 1 The U3606B in BriefU3606B User’s Guide 19Using the Shift keyTo select a Shift function: first, press [Shift] (the Shift annunciator wil

Strona 136 - Enable remote sensing

1 Introduction The U3606B in Brief20 U3606B User’s Guide• Press [Shift] to select a shift function.• Press [Local] to unlock the front-panel keys whe

Strona 137 - Output rating

Introduction 1 The U3606B in BriefU3606B User’s Guide 21• Press [] to select the resistance (2-wire) measurement function.• Press [] again to select t

Strona 138 - Output noise

1 Introduction The U3606B in Brief22 U3606B User’s Guide• Press [] to select a higher range and disable autoranging.• Press [] to select a lower rang

Strona 139 - System-Related Operation

Introduction 1 The U3606B in BriefU3606B User’s Guide 23 Press [Shift] > [Limit] to set the over-current limit value for the CV output or the over-

Strona 140 - Using the Utility Menu

IV U3606B User’s GuideSafety ConsiderationsRead the information below before using this instrument. The following general safety precautions must be o

Strona 141 - U3606B User’s Guide 125

1 Introduction The U3606B in Brief24 U3606B User’s GuideInput/Output terminalsFigure 1-9 The input/output terminals at a glanceWARNINGBefore attempti

Strona 142 - Utility Menu Summary

Introduction 1 The U3606B in BriefU3606B User’s Guide 25Table 1 - 5 Input terminal connections Function Input terminals (+ SENSE –) Input protectionDC

Strona 143 - U3606B User’s Guide 127

1 Introduction The U3606B in Brief26 U3606B User’s GuideTable 1 - 6 Output terminal connections Function Output terminals (+ FORCE –) Maximum outputC

Strona 144 - 128 U3606B User’s Guide

Introduction 1 The U3606B in BriefU3606B User’s Guide 27Square-wave output• Amplitude: 0 V to 30 V[1]• Frequency: Multiple predefined values[3]• Duty

Strona 145 - Utility Menu Items

1 Introduction The U3606B in Brief28 U3606B User’s GuideTHIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.U3606-90054_UG_EN.book Page 28 Friday, July 11,

Strona 146

29U3606B Multimeter|DC Power SupplyUser’s GuideAgilent Technologies2Operation and FeaturesMeasuring Voltage 30Measuring Current 33Measuring Resi

Strona 147

2 Operation and Features Measuring Voltage30 U3606B User’s GuideMeasuring VoltageConnect the test leadsSelect the voltage measurement function124Pres

Strona 148 - Enabling refresh hold

Operation and Features 2 Measuring VoltageU3606B User’s Guide 31Voltage measurement summaryProbe the test points and read the displayIn this example,

Strona 149 - Setting the smooth function

2 Operation and Features Measuring Voltage32 U3606B User’s GuideAC voltage measurementAvailable ranges 100.000 mV, 1.00000 V, 10.0000 V, 100.000 V, 7

Strona 150

Operation and Features 2 Measuring CurrentU3606B User’s Guide 33Measuring CurrentConnect the test leadsSelect the current measurement function124Press

Strona 151

U3606B User’s Guide VEnvironmental ConditionsThis instrument is designed for indoor use and in an area with low condensation. The table below shows th

Strona 152

2 Operation and Features Measuring Current34 U3606B User’s GuideCurrent measurement summaryProbe the test points and read the displayIn this example,

Strona 153

Operation and Features 2 Measuring CurrentU3606B User’s Guide 35AC current measurementAvailable ranges 10.0000 mA, 100.000 mA, 1.00000 A, 3.0000 AMeas

Strona 154

2 Operation and Features Measuring Resistance36 U3606B User’s GuideMeasuring ResistanceConnect the test leadsSelect the resistance measurement functi

Strona 155 - Number of

Operation and Features 2 Measuring ResistanceU3606B User’s Guide 37Probe the test points and read the displayIn this example, we obtain a resistance m

Strona 156

2 Operation and Features Measuring Resistance38 U3606B User’s GuideResistance measurement summaryTable 2 - 3 Resistance measurement summary Item Desc

Strona 157

Operation and Features 2 Testing ContinuityU3606B User’s Guide 39Test ing Conti nuityConnect the test leadsSelect the continuity test function124Press

Strona 158 - Performing a self-test

2 Operation and Features Testing Continuity40 U3606B User’s GuideProbe the test points and read the displayIn this example, a short is detected in th

Strona 159

Operation and Features 2 Testing ContinuityU3606B User’s Guide 41Continuity test summaryTable 2 - 4 Continuity test summary Item DescriptionMeasuremen

Strona 160 - Configuring the beeper

2 Operation and Features Measuring Low-Resistance42 U3606B User’s GuideMeasuring Low-ResistanceConnect the test leads1234U3606-90054_UG_EN.book Page

Strona 161 - Changing the power-on state

Operation and Features 2 Measuring Low-ResistanceU3606B User’s Guide 43Select the low-resistance measurement functionProbe the test points and read th

Strona 162

VI U3606B User’s GuideRegulatory MarkingsThe CE mark is a registered trademarkof the European Community. This CEmark shows that the product complieswi

Strona 163

2 Operation and Features Measuring Low-Resistance44 U3606B User’s GuideLow-resistance measurement summaryCAUTIONDisconnect circuit power and discharg

Strona 164 - Storing a state

Operation and Features 2 Measuring Low-ResistanceU3606B User’s Guide 45Table 2 - 6 Low-resistance test current values[1][1] When the display shows “OL

Strona 165 - Recalling a stored state

2 Operation and Features Measuring Low-Resistance46 U3606B User’s GuideChanging the low-resistance test currentUse the arrow keys to navigate the edi

Strona 166 - Remote Operation

Operation and Features 2 Measuring CapacitanceU3606B User’s Guide 47Measuring CapacitanceConnect the test leadsSelect the capacitance measurement func

Strona 167 - GPIB address

2 Operation and Features Measuring Capacitance48 U3606B User’s GuideProbe the test points and read the displayIn this example, we obtain a capacitanc

Strona 168 - SCPI commands

Operation and Features 2 Measuring CapacitanceU3606B User’s Guide 49Capacitance measurement summaryNOTEMeasuring tips• The U3606B calculates capacitan

Strona 169 - SCPI query time-out

2 Operation and Features Testing Diodes50 U3606B User’s GuideTest ing DiodesConnect the test leadsSelect the diode test function124Press [] to switch

Strona 170 - 154 U3606B User’s Guide

Operation and Features 2 Testing DiodesU3606B User’s Guide 51Probe the test points and read the displayIn this example, we obtain an open result from

Strona 171 - Agilent Technologies

2 Operation and Features Testing Diodes52 U3606B User’s GuideDiode test summaryCAUTIONDisconnect circuit power and discharge all high-voltage capacit

Strona 172 - Product Characteristics

Operation and Features 2 Measuring Frequency/Pulse Width/Duty Cycle (Voltage Path)U3606B User’s Guide 53Measuring Frequency/Pulse Width/Duty Cycle (Vo

Strona 173 - U3606B User’s Guide 157

U3606B User’s Guide VIIWaste Electrical and Electronic Equipment (WEEE) Directive 2002/96/ECThis instrument complies with the WEEE Directive (2002/96/

Strona 174 - Specification assumptions

2 Operation and Features Measuring Frequency/Pulse Width/Duty Cycle (Voltage Path)54 U3606B User’s GuideProbe the test points and read the displayIn

Strona 175 - DC specifications

Operation and Features 2 Measuring Frequency/Pulse Width/Duty Cycle (Voltage Path)U3606B User’s Guide 55Frequency/pulse width/duty cycle measurement (

Strona 176 - 160 U3606B User’s Guide

2 Operation and Features Measuring Frequency/Pulse Width/Duty Cycle (Current Path)56 U3606B User’s GuideMeasuring Frequency/Pulse Width/Duty Cycle (C

Strona 177 - U3606B User’s Guide 161

Operation and Features 2 Measuring Frequency/Pulse Width/Duty Cycle (Current Path)U3606B User’s Guide 57Probe the test points and read the displayIn t

Strona 178

2 Operation and Features Measuring Frequency/Pulse Width/Duty Cycle (Current Path)58 U3606B User’s GuideFrequency/pulse width/duty cycle measurement

Strona 179 - AC specifications

Operation and Features 2 Selecting a RangeU3606B User’s Guide 59Selecting a RangeYou can allow the U3606B to automatically select the range using auto

Strona 180

2 Operation and Features Selecting a Range60 U3606B User’s GuideNOTE• Autoranging is selected at default factory power-on and after a remote reset.•

Strona 181 - Frequency specifications

Operation and Features 2 Setting the ResolutionU3606B User’s Guide 61Setting the ResolutionYou can select either 4½ digit or 5½ digit resolution for t

Strona 182 - 166 U3606B User’s Guide

2 Operation and Features Math Operations62 U3606B User’s GuideMath OperationsThe U3606B provides six math operations: null measurements, dB measureme

Strona 183 - Operating specifications

Operation and Features 2 Math OperationsU3606B User’s Guide 63NullWhen making null measurements, also called relative, each reading is the difference

Strona 184 - (continued)

VIII U3606B User’s GuideDeclaration of Conformity (DoC)The Declaration of Conformity (DoC) for this instrument is available on the Agilent website. Yo

Strona 185 - Supplemental characteristics

2 Operation and Features Math Operations64 U3606B User’s GuideEnable the null functionTo disable the null functionU3606-90054_UG_EN.book Page 64 Fr

Strona 186 - 170 U3606B User’s Guide

Operation and Features 2 Math OperationsU3606B User’s Guide 65Edit the null valueUse the arrow keys to navigate the edit mode.12• Press [] or [] to se

Strona 187 - U3606B User’s Guide 171

2 Operation and Features Math Operations66 U3606B User’s GuidedBm measurementsThe logarithmic dBm (decibels relative to 1 mW) scale is often used in

Strona 188 - 172 U3606B User’s Guide

Operation and Features 2 Math OperationsU3606B User’s Guide 67dB measurementsEach dB measurement is the difference between the input signal and a stor

Strona 189 - Specifications assumptions

2 Operation and Features Math Operations68 U3606B User’s GuideEdit the relative valueUse the arrow keys to navigate the edit mode.12• Press [] or []

Strona 190 - Performance specifications

Operation and Features 2 Math OperationsU3606B User’s Guide 69MinMaxThe MinMax operation stores the minimum and maximum values, the average, and the n

Strona 191 - U3606B User’s Guide 175

2 Operation and Features Math Operations70 U3606B User’s GuideLimitThe limit test function enables you to perform pass or fail testing to the upper a

Strona 192

Operation and Features 2 Math OperationsU3606B User’s Guide 71Enable the Limit function• PASS: Readings are within the specified limits. • HI: Reading

Strona 193 - U3606B User’s Guide 177

2 Operation and Features Math Operations72 U3606B User’s GuideEdit the upper and lower limit valuesUse the arrow keys to navigate the edit mode.Save

Strona 194

Operation and Features 2 Math OperationsU3606B User’s Guide 73HoldThe refresh hold feature allows you to capture and hold a reading, within the specif

Strona 195 - Sweep characteristics

U3606B User’s Guide IXTable of Contents1 IntroductionAbout This Manual 2Documentation map 2Safety notes 2Preparing the U3606B 3Che

Strona 196 - 180 U3606B User’s Guide

2 Operation and Features Math Operations74 U3606B User’s GuideEnable the Hold functionTo disable the Hold functionU3606-90054_UG_EN.book Page 74 Fr

Strona 197 - List of Error Messages

Operation and Features 2 Triggering the MultimeterU3606B User’s Guide 75Triggering the MultimeterThe U3606B triggering system allows you to generate t

Strona 198 - Error Messages

2 Operation and Features Triggering the Multimeter76 U3606B User’s GuideFront panel triggeringSingle triggeringThe U3606B takes one reading each time

Strona 199 - Command errors

Operation and Features 2 Triggering the MultimeterU3606B User’s Guide 77Remote interface triggeringImmediate triggeringIn the immediate trigger mode,

Strona 200 - Execution errors

2 Operation and Features Triggering the Multimeter78 U3606B User’s GuideRemote interface operation:• The TRIGger:SOURce BUS command selects the bus

Strona 201 - Device specific errors

79U3606B Multimeter|DC Power SupplyUser’s GuideAgilent Technologies3DC Power Supply OperationConstant Voltage Operation 80Constant Current Operatio

Strona 202 - Self-test errors

3 DC Power Supply Operation Constant Voltage Operation80 U3606B User’s GuideConstant Voltage OperationConnect the load1LOAD32U3606-90054_UG_EN.book

Strona 203 - Calibration errors

DC Power Supply Operation 3 Constant Voltage OperationU3606B User’s Guide 81Select the constant voltage functionAdjust the constant voltage value5LOAD

Strona 204 - 188 U3606B User’s Guide

3 DC Power Supply Operation Constant Voltage Operation82 U3606B User’s GuideEnable the output8NOTE• The output voltage is limited by the range select

Strona 205

DC Power Supply Operation 3 Constant Current OperationU3606B User’s Guide 83Constant Current OperationConnect the load1LOAD32U3606-90054_UG_EN.book P