Power Meter Operation
How Measurements are Calculated
Agilent E4418B Users Guide 2-63
How Measurements are Calculated
Figure 2-22 details how measurements are calculated. It shows the
position in which the various power meter functions are implemented in
the measurement calculation.
Figure 2-22: How Measurements are Calculated
Cal Factor
Channel Functions Window Functions
Averaging
Channel Duty
Offset Cycle
Display
Relative
Offset
Channel A
Upper Window
Limits
Recorder
Output
Freq Dep
Offset
Window
Limits
Display
Relative
Offset
Lower Window
Window
Limits
HP4402.book Page 63 Wednesday, November 29, 2000 4:46 PM