Agilent Technologies N9344C Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Pomiary, testowanie i kontrola Agilent Technologies N9344C. N9344C Handheld Spectrum Analyzer (HSA) Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 10
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Agilent N9344C Handheld
Spectrum Analyzer (HSA)
20 GHz
Data Sheet
Field testing just got easier
www.agilent.com/find/hsa
If you are making measurements in the field, the Agilent
N9344C handheld spectrum analyzer (HSA) makes your
job easier. It's got the features you need for operating in
tough field environments, and its measurement perfor-
mance gives you confidence the job's been done right.
The N9344C HSA lets you automate routine tasks to save
time and ensure consistent results. Field testing just got
easier with the Agilent N9344C HSA.
Przeglądanie stron 0
1 2 3 4 5 6 7 8 9 10

Podsumowanie treści

Strona 1 - Spectrum Analyzer (HSA)

Agilent N9344C Handheld Spectrum Analyzer (HSA)20 GHzData SheetField testing just got easier www.agilent.com/find/hsaIf you are making measurements i

Strona 2

myAgilentmyAgilentwww.agilent.com/find/myagilentA personalized view into the information most relevant to you.Three-Year Warrantywww.agilent.com/find/

Strona 3 - Specifications

2Definitions and requirementsThis data sheet contains specifications and supplemental information for Agilent N9344C handheld spectrum analyzer. The d

Strona 4 - Specifications (continued)

3SpecificationsSpecification Supplemental informationFrequencyFrequency range 1 MHz to 20 GHz (usable to 9 kHz) AC coupledInternal 10 MHz frequency ref

Strona 5

4Specifications (continued)Amplitude specifications Supplemental informationMeasurement range1 to 500 MHz Displayed average noise level (DANL) to +10 d

Strona 6

5Specifications (continued)Amplitude specifications (continued) Supplemental informationLevel display range (continued)Level measurement error1 MHz to

Strona 7

6Specifications (continued)Sweep specifications Supplemental informationSweep timeRange 2 ms to 1000 s Span ≥ 100 Hz600 ns to 200 s Span = 0 Hz (zero s

Strona 8

7Specifications (continued)General specifications (continued) Supplemental informationPower requirements and calibrationAdaptor voltage 100 to 240 V AC

Strona 9

8Option specifications (continued) Supplemental informationAM/FM modulation analysis (Option AMA)Frequency range 10 MHz to 20 GHzCarrier power accurac

Strona 10 - (BP-09-27-13)

9Option specifications (continued) Supplemental informationTime-gated spectrum analysis (Option TMG)Gated sweep (continued)Gate sources ExternalRF bur