Agilent Technologies E1465A Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Pomiary, testowanie i kontrola Agilent Technologies E1465A. Agilent Technologies Bench and System Switching Products Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Agilent Technologies

Agilent TechnologiesBench and System Switching Products

Strona 2 - Surrounding Your DUT

10· Standaloneandmodularcapabilities· Upto3MSa/ssamplingrate(singlechannel;U2331A)· Upto384channelswhenusedinU2781Achassis·

Strona 3 - Contents

 11Agilent Measurement Manager application user interface www.agilent.com/nd/usbdaq ⎮ Models and specificationsModel DescriptionU2781A USBModu

Strona 4

12• Affordable,scalableswitchingplatformwith21modules to choose form• 2,5and14-slotMainframes• Intuitive,self-guidingfrontpanelinter

Strona 5

 13 www.agilent.com/nd/3499 ⎮ Models and specificationsModel Description3499A 5-SlotSwitch/ControlMainframe3499B 2-SlotSwitch/ControlMainf

Strona 6

14 SelectfromGeneralPurpose,Matrix,MultiplexerandRFSwitchmodulesforyourswitchtestsystem.AddDigitalI/Otoyourtestsystemwiththe

Strona 7

 15 www.agilent.com/nd/pxi ⎮ M9018A 18 slot PXIe Chassis• AdvancedPCIeswitchfabricthatoperatesuptoGen2speedsandprovidestwelvex

Strona 8

16PXI Switch Modules ⎮ www.agilent.com/nd/pxiOptions and Accessories M9130A,M9120A,M9187A  Y1181A*  PXIconnectorblock:78pin,shielded,

Strona 9

 17 www.agilent.com/nd/pxi ⎮ Models and specifications Description Switch Speed Max voltage Max Switch/ Carry CurrentGeneral Purpose Switch

Strona 10

18• Modulararchitectureallowsforhigh-performancesignalconnectionsinthesameplatformasyourVXIbus-basedsignal stimulus and measurement ins

Strona 11 - Models and specifications

 19 www.agilent.com/nd/vxi ⎮ Models and specificationsPlug-in modules Description Type Max volts/current Scan ch/secMultiplexers E1345A 16

Strona 12 - 3499 Switch Family

2RF/MW SourceDigital Pattern/PulseFunction GeneratorArbitrary WaveformGeneratorDUTInputtuptuOelbaCXUM golanAelbaChctiwS FRXUM golanAelbaCRF/MWSignal A

Strona 13

20• Highreliabilityandexceptionalrepeatabilityensureexcellent measurement accuracy• ExcellentRFspecicationsoptimizeyourtest system capa

Strona 14 - PXI Switch Modules

 21 www.agilent.com/nd/switches ⎮ Models and specificationsElectromechanical switchesFrequency Configuration SPDT SP3T SP4T SP5T SP6T Bypass

Strona 15 - RF PXI Switch Modules

22• Superiorperformancewithhighisolation• Fastswitchingspeedacrossabroadoperating frequencyrange• Safe,accuratetestforsensitiveRFI

Strona 16

23Solid State Switches Frequency FET Hybrid PIN Diode Configuration SPDT SP4T Transfer SPDT SP4T Transfer 300 kHz to 8 GHz n  n   100

Strona 17

24• Flexible,standaloneswitchdrivers• Quicklyandeasilyconnecttoyourswitches• Controlfromjustafewtoover256highfrequencyswitches•

Strona 18 - VXI Switches

 25www.agilent.com/nd/switchdrivers⎮ Models and specificationsSwitch Driver Quick Selection ChartFeature 11713B/C L4445A L4490/91A 34980A with

Strona 19

26• Flexibleandeasilycongurableswitchmountingsystemfora robust and reliable signal routing system• 3Dmodelsforquicklayoutanddocumen

Strona 20 - Electromechanical Switches

 27Models and specificationsThe L449xA RF Switch Platforms provide the tools for Engineers to build their own custom switch solution. These platforms

Strona 21

28• Aerospace/DefenseandWirelessRF/microwavedesignedswitching and signal conditioning solutions• DeepexpertiseinRF/microwaveinstrumentation

Strona 22 - Solid State Switches

 29SpecificationsAttribute Specifications and DescriptionsFrequencyRange DCto70GHzRFSwitching MechanicalorsolidstateswitchesfromAgilent

Strona 23

3Whether you use switching to route signals for design verification applications or for complex automated functional test systems, reliable and repeat

Strona 24 - Switch Drivers

30 ⎮ www.agilent.com/nd/openThe Move is on.MoreandmorecompaniesaremovingtheirtestsystemstotheLANeXtensionsforInstrumentation(LXI)pl

Strona 25

 31 www.agilent.com/nd/open ⎮ New Agilent LXI Digitizers with high-performance front-ends and on-board measurements to save you timeThe Agilent L4

Strona 26 - L449XA RF Switch Platforms

Agilent Email Updateswww.agilent.com/find/emailupdatesGet the latest information on the products and applications you select. www.lxistandard.orgLAN e

Strona 27 - Options and Accessories

4• Three-slotmainframe,choiceof8plug-inmodules• Upto602-wiremuxor962-wirematrixcross-pointsin one mainframe• Built-inDMMwi

Strona 28 - Custom Switch Solutions

5Models and specificationsIncluded BenchLink Data Logger softwaremakesiteasytocapturedatafor further analysis.Agilent 34830A BenchLink Data Log

Strona 29 - Specifications

6• Eight-slotmainframe,choiceof21-plug-inmodules• Upto5602-wiremuxor4096matrixcross-pointsinonemainframe• Built-inDMMwith6

Strona 30 - The Move is on

7Models and specifications www.agilent.com/nd/34980A ⎮ Model Description34980A 8-slotmainframewithoptionalinternal6½digitDMMand500kread

Strona 31

8• LXIClassCCompliant• Small,1U,half-racksize• Built-inEthernetconnectivity• Fully-featuredgraphicalWebinterface• StandardDsubconnec

Strona 32 - Certified

9Web interfacemakesiteasytosetup,troubleshoot and maintain your test remotelyOptions and Accessories• OptionGPIBaddsGPIBinterface• Optio