Agilent Technologies FS2010 Instrukcja Obsługi Strona 1

Przeglądaj online lub pobierz Instrukcja Obsługi dla Oprogramowanie Agilent Technologies FS2010. Agilent Technologies FS2010 Technical data Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - (With Remote Operation

Agilent TechnologiesAgilent Technologies Signal GeneratorsE4428C/38C ESG RFE8663B/E8663D PSG RF AnalogN5161A/62A/81A/82A MXG RFE8257D/67D PSG Microwav

Strona 2

2 Agilent Signal Generators Programming GuideGetting Started with Remote OperationProgramming and Software/Hardware LayersProgramming and Software/Har

Strona 3 - Contents

92 Agilent Signal Generators Programming GuideProgramming ExamplesGPIB Programming Interface Examples////*********************************************

Strona 4

Agilent Signal Generators Programming Guide 93Programming ExamplesGPIB Programming Interface Examplesgetch(); viPrintf(vi, "FREQ:MODE?\n");

Strona 5

94 Agilent Signal Generators Programming GuideProgramming ExamplesGPIB Programming Interface Examples// printed to the to the display window.////*****

Strona 6

Agilent Signal Generators Programming Guide 95Programming ExamplesGPIB Programming Interface Examplesprintf("Source RF state is : on\n");}el

Strona 7

96 Agilent Signal Generators Programming GuideProgramming ExamplesGPIB Programming Interface Examples// PROGRAM FILE NAME:visaex5.cpp//// PROGRAM DESC

Strona 8

Agilent Signal Generators Programming Guide 97Programming ExamplesGPIB Programming Interface ExamplesviPrintf(vi, "POW:AMPL -2.5 dBm\n"); //

Strona 9

98 Agilent Signal Generators Programming GuideProgramming ExamplesGPIB Programming Interface Examples#include <conio.h>void main (){ViSession de

Strona 10 - interfaces:

Agilent Signal Generators Programming Guide 99Programming ExamplesGPIB Programming Interface ExamplesviClose(defaultRM);}Generating a Step-Swept Signa

Strona 11 - Interfaces

100 Agilent Signal Generators Programming GuideProgramming ExamplesGPIB Programming Interface Examplesprintf("\n");exit(0);}viClear(vi);

Strona 12

Agilent Signal Generators Programming Guide 101Programming ExamplesGPIB Programming Interface Examples// sweep from 1-2 GHz. A loop and counter are us

Strona 13 - Agilent IO Libraries Suite

Agilent Signal Generators Programming Guide 3Getting Started with Remote OperationInterfacesInterfacesGPIB GPIB is used extensively when a dedicated c

Strona 14

102 Agilent Signal Generators Programming GuideProgramming ExamplesGPIB Programming Interface Examples stat = viPrintf(inst, "SWEEP:POINTS %d

Strona 15

Agilent Signal Generators Programming Guide 103Programming ExamplesGPIB Programming Interface ExamplesLaunch Microsoft Visual C++ 6.0, add the require

Strona 16

104 Agilent Signal Generators Programming GuideProgramming ExamplesGPIB Programming Interface Examplesif(viStatus){// If problems, then prompt user

Strona 17

Agilent Signal Generators Programming Guide 105Programming ExamplesGPIB Programming Interface Examplesprintf("The signal generator has been retur

Strona 18

106 Agilent Signal Generators Programming GuideProgramming ExamplesGPIB Programming Interface Examples// questionable status register is read. // The

Strona 19 - Using the Web Browser

Agilent Signal Generators Programming Guide 107Programming ExamplesGPIB Programming Interface Examplesgetch(); // Wai

Strona 20

108 Agilent Signal Generators Programming GuideProgramming ExamplesGPIB Programming Interface Examples // bits '0','1',&ap

Strona 21

Agilent Signal Generators Programming Guide 109Programming ExamplesGPIB Programming Interface ExamplesReading the Service Request Interrupt (SRQ) Usin

Strona 22 - ESG/PSG Web Server On

110 Agilent Signal Generators Programming GuideProgramming ExamplesGPIB Programming Interface Examplesint sweep=1; // End of sweep flag /* Pr

Strona 23

Agilent Signal Generators Programming Guide 111Programming ExamplesGPIB Programming Interface ExamplesviPrintf(vi, "*CLS\n");// Clears signa

Strona 24

4 Agilent Signal Generators Programming GuideGetting Started with Remote OperationIO Libraries and Programming LanguagesIO Libraries and Programming L

Strona 25

112 Agilent Signal Generators Programming GuideProgramming ExamplesGPIB Programming Interface ExamplesviStatus = viClose(defaultRM);return 0;}// The f

Strona 26

Agilent Signal Generators Programming Guide 113Programming ExamplesGPIB Programming Interface ExamplesUsing 8757D Pass-Thru Commands (PSG with Option

Strona 27 - Preferences

114 Agilent Signal Generators Programming GuideProgramming ExamplesGPIB Programming Interface ExamplesGPIB Address AssignmentsFigure 3- 1 describes ho

Strona 28 - Getting Help (ESG/PSG)

Agilent Signal Generators Programming Guide 115Programming ExamplesGPIB Programming Interface Examples40 OUTPUT 717;"SYST:LANG SCPI";END50 W

Strona 29

116 Agilent Signal Generators Programming GuideProgramming ExamplesLAN Programming Interface Examples4. Insert line 115, that recalls state 1, (RC1).1

Strona 30 - Troubleshooting

Agilent Signal Generators Programming Guide 117Programming ExamplesLAN Programming Interface ExamplesVXI-11 Programming Using SICL and C++The followin

Strona 31 - Error Messages

118 Agilent Signal Generators Programming GuideProgramming ExamplesLAN Programming Interface Examples // Open SICL instrument handle us

Strona 32 - Error Message Types

Agilent Signal Generators Programming Guide 119Programming ExamplesLAN Programming Interface Examples// NOTE: You must have the Agilent Libraries inst

Strona 33 - 2 Using IO Interfaces

120 Agilent Signal Generators Programming GuideProgramming ExamplesLAN Programming Interface Examples status = viWrite(instr, (ViBuf)"*IDN?\n&quo

Strona 34 - Using GPIB

Agilent Signal Generators Programming Guide 121Programming ExamplesLAN Programming Interface Examples2. At the UNIX prompt in your home directory type

Strona 35 - Set Up the GPIB Interface

Agilent Signal Generators Programming Guide 5Getting Started with Remote OperationIO Libraries and Programming LanguagesCAUTION For long strings of co

Strona 36 - Verify GPIB Functionality

122 Agilent Signal Generators Programming GuideProgramming ExamplesLAN Programming Interface Examples5. After you cd to the directory where the lanio.

Strona 37 - GPIB Interface Terms

Agilent Signal Generators Programming Guide 123Programming ExamplesLAN Programming Interface ExamplesQueries for Lan Using Socketslanio.c and getopt.c

Strona 38

124 Agilent Signal Generators Programming GuideProgramming ExamplesLAN Programming Interface Examples * * This program compiles and runs under *

Strona 39 - Using LAN

Agilent Signal Generators Programming Guide 125Programming ExamplesLAN Programming Interface Examples#include <windows.h># ifndef _WINSOCKAPI_#

Strona 40 - Setting Up the LAN Interface

126 Agilent Signal Generators Programming GuideProgramming ExamplesLAN Programming Interface Examples fprintf(stderr," %s [-nqu] <hos

Strona 41

Agilent Signal Generators Programming Guide 127Programming ExamplesLAN Programming Interface Examples * * $Parameters: $ * (const char *) hostname

Strona 42

128 Agilent Signal Generators Programming GuideProgramming ExamplesLAN Programming Interface Examples memcpy(&peeraddr_in.sin_addr.s_addr, host

Strona 43

Agilent Signal Generators Programming Guide 129Programming ExamplesLAN Programming Interface Examples if (count == SOCKET_ERROR) { return CO

Strona 44 - Verifying LAN Functionality

130 Agilent Signal Generators Programming GuideProgramming ExamplesLAN Programming Interface Examples return NULL; } else { return re

Strona 45

Agilent Signal Generators Programming Guide 131Programming ExamplesLAN Programming Interface Examples{ long ch; char tmp_buf[8]; long resultB

Strona 46

6 Agilent Signal Generators Programming GuideGetting Started with Remote OperationIO Libraries and Programming Languagesinstructions in the setup wiza

Strona 47

132 Agilent Signal Generators Programming GuideProgramming ExamplesLAN Programming Interface Examples if (numDigits) {

Strona 48

Agilent Signal Generators Programming Guide 133Programming ExamplesLAN Programming Interface Examples } } else {

Strona 49

134 Agilent Signal Generators Programming GuideProgramming ExamplesLAN Programming Interface Examples * Don't bother decoding. **

Strona 50 - Using VXI–11

Agilent Signal Generators Programming Guide 135Programming ExamplesLAN Programming Interface Examples { if (*query == ' ')

Strona 51 - Using Sockets LAN

136 Agilent Signal Generators Programming GuideProgramming ExamplesLAN Programming Interface Examples basename = argv[0]; while ( ( chr =

Strona 52 - Using Telnet LAN

Agilent Signal Generators Programming Guide 137Programming ExamplesLAN Programming Interface Examples { /* no hostname! */ usage(base

Strona 53

138 Agilent Signal Generators Programming GuideProgramming ExamplesLAN Programming Interface Examples { commandInstrument(instSock,

Strona 54

Agilent Signal Generators Programming Guide 139Programming ExamplesLAN Programming Interface Examples fwrite(charBuf + strlen(charB

Strona 55 - Figure 2-7 Telnet 2000 Window

140 Agilent Signal Generators Programming GuideProgramming ExamplesLAN Programming Interface Examplesint main1(){ SOCKET instSock;long bufBytes; ch

Strona 56 - Using FTP

Agilent Signal Generators Programming Guide 141Programming ExamplesLAN Programming Interface Examples close(instSock);#endif /* WINSOCK */ retur

Strona 57 - Figure 2-8 FTP Screen

Agilent Signal Generators Programming Guide 7Getting Started with Remote OperationIO Libraries and Programming LanguagesUsing VISA Configuration (Manu

Strona 58 - Using LXI

142 Agilent Signal Generators Programming GuideProgramming ExamplesLAN Programming Interface Examplesstatic char *scan = NULL; /* Private scan p

Strona 59

Agilent Signal Generators Programming Guide 143Programming ExamplesLAN Programming Interface Examples return(c);}Sockets LAN Programming Using

Strona 60

144 Agilent Signal Generators Programming GuideProgramming ExamplesLAN Programming Interface Examples Socket t = new Socket(instrumentName,5025)

Strona 61

Agilent Signal Generators Programming Guide 145Programming ExamplesLAN Programming Interface ExamplesSockets LAN Programming Using PerlThis example us

Strona 62

146 Agilent Signal Generators Programming GuideProgramming ExamplesLAN Programming Interface Examples# Send identification query print $sock "*ID

Strona 63

Agilent Signal Generators Programming Guide 147Programming ExamplesLAN Programming Interface Examples% [corrFilter] = loadPsaEqFilter(psaDev[, destRat

Strona 64

148 Agilent Signal Generators Programming GuideProgramming ExamplesLAN Programming Interface ExamplesinvertedFreqDomain = 1./coeffs;% convert to time

Strona 65

Agilent Signal Generators Programming Guide 149Programming ExamplesLAN Programming Interface ExamplesExample 2: Reading a VSA Trace and Setting up the

Strona 66

150 Agilent Signal Generators Programming GuideProgramming ExamplesLAN Programming Interface Examples centeredTime(center:len) = timeDomain(1:c

Strona 67

Agilent Signal Generators Programming Guide 151Programming ExamplesLAN Programming Interface Examples% This value should be 256 for the Equalization f

Strona 68

8 Agilent Signal Generators Programming GuideGetting Started with Remote OperationIO Libraries and Programming LanguagesWindows NT and Agilent IO Libr

Strona 69

152 Agilent Signal Generators Programming GuideProgramming ExamplesRS-232 Programming Interface Examples (ESG/PSG Only)fopen(t);%for writing to a file

Strona 70

Agilent Signal Generators Programming Guide 153Programming ExamplesRS-232 Programming Interface Examples (ESG/PSG Only)Watch for the signal generator’

Strona 71

154 Agilent Signal Generators Programming GuideProgramming ExamplesRS-232 Programming Interface Examples (ESG/PSG Only)//*****************************

Strona 72

Agilent Signal Generators Programming Guide 155Programming ExamplesRS-232 Programming Interface Examples (ESG/PSG Only) printf("Check instrume

Strona 73

156 Agilent Signal Generators Programming GuideProgramming ExamplesRS-232 Programming Interface Examples (ESG/PSG Only)120 INTEGER Num130 DIM St

Strona 74 - If You Have Problems

Agilent Signal Generators Programming Guide 157Programming ExamplesRS-232 Programming Interface Examples (ESG/PSG Only)Queries for RS-232 Using VISA a

Strona 75

158 Agilent Signal Generators Programming GuideProgramming ExamplesRS-232 Programming Interface Examples (ESG/PSG Only)ViSessiondefaultRM, instr;// De

Strona 76

Agilent Signal Generators Programming Guide 1594 Programming the Status Register SystemThis chapter provides the following major sections:• Overview

Strona 77 - Using USB (Agilent MXG)

160 Agilent Signal Generators Programming GuideProgramming the Status Register SystemOverviewconditions. The lower level status registers are grouped

Strona 78 - Setting Up the USB Interface

Agilent Signal Generators Programming Guide 161Programming the Status Register SystemOverviewOverall Status Byte Register Systems• “N5161A/62A/81A/82A

Strona 79

Agilent Signal Generators Programming Guide 9Getting Started with Remote OperationIO Libraries and Programming LanguagesVISA Configuration (Automatic)

Strona 80

162 Agilent Signal Generators Programming GuideProgramming the Status Register SystemOverviewFigure 4-1 N5161A/62A/81A/82A/83A: Overall Status Byte Re

Strona 81 - 3 Programming Examples

Agilent Signal Generators Programming Guide 163Programming the Status Register SystemOverviewFigure 4-2 N5161A/62A/81A/82A/83A: Overall Status Byte Re

Strona 82 - Running C++ Programs

164 Agilent Signal Generators Programming GuideProgramming the Status Register SystemOverviewFigure 4-3 E4428C/38C: Overall Status Byte Register Syst

Strona 83 - Running Basic Examples

Agilent Signal Generators Programming Guide 165Programming the Status Register SystemOverviewFigure 4-4 E4428C/38C: Overall Status Byte Register Syste

Strona 84 - Running Java Examples

166 Agilent Signal Generators Programming GuideProgramming the Status Register SystemOverviewFigure 4-5 E8257N/57D/67D and E8663B/63D: Overall Status

Strona 85

Agilent Signal Generators Programming Guide 167Programming the Status Register SystemOverviewFigure 4-6 E8257N/57D/67D and E8663B/63D: Overall Status

Strona 86

168 Agilent Signal Generators Programming GuideProgramming the Status Register SystemStatus Register Bit ValuesStatus Register Bit ValuesEach bit in a

Strona 87

Agilent Signal Generators Programming Guide 169Programming the Status Register SystemAccessing Status Register InformationAccessing Status Register In

Strona 88 - Clear Function

170 Agilent Signal Generators Programming GuideProgramming the Status Register SystemAccessing Status Register InformationThe polling method works wel

Strona 89 - Output Function

Agilent Signal Generators Programming Guide 171Programming the Status Register SystemAccessing Status Register InformationRefer to Figure 4- 1 on page

Strona 90

10 Agilent Signal Generators Programming GuideGetting Started with Remote OperationIO Libraries and Programming LanguagesSelecting IO Libraries for GP

Strona 91

172 Agilent Signal Generators Programming GuideProgramming the Status Register SystemAccessing Status Register Information*ESE, *ESE? (event status en

Strona 92

Agilent Signal Generators Programming Guide 173Programming the Status Register SystemAccessing Status Register InformationTable 4-2 Effects of :STATus

Strona 93

174 Agilent Signal Generators Programming GuideProgramming the Status Register SystemAccessing Status Register Information:STATus:QUEStionable:PTRansi

Strona 94

Agilent Signal Generators Programming Guide 175Programming the Status Register SystemStatus Byte GroupStatus Byte GroupThe Status Byte Group includes

Strona 95

176 Agilent Signal Generators Programming GuideProgramming the Status Register SystemStatus Byte GroupStatus Byte RegisterService Request Enable Regis

Strona 96

Agilent Signal Generators Programming Guide 177Programming the Status Register SystemStatus GroupsStatus GroupsThe Standard Operation Status Group an

Strona 97

178 Agilent Signal Generators Programming GuideProgramming the Status Register SystemStatus GroupsStandard Event Status GroupThe Standard Event Status

Strona 98

Agilent Signal Generators Programming Guide 179Programming the Status Register SystemStatus GroupsStandard Event Status RegisterStandard Event Status

Strona 99

180 Agilent Signal Generators Programming GuideProgramming the Status Register SystemStatus GroupsStandard Operation Status GroupNOTE Some of the bits

Strona 100 - Programming Examples

Agilent Signal Generators Programming Guide 181Programming the Status Register SystemStatus GroupsStandard Operation Condition RegisterThe Standard Op

Strona 101

Agilent Signal Generators Programming Guide 11Getting Started with Remote OperationUsing the Web BrowserProgramming LanguagesAlong with Standard Comma

Strona 102

182 Agilent Signal Generators Programming GuideProgramming the Status Register SystemStatus GroupsStandard Operation Transition Filters (negative and

Strona 103

Agilent Signal Generators Programming Guide 183Programming the Status Register SystemStatus GroupsBaseband Operation Status GroupNOTE This status grou

Strona 104

184 Agilent Signal Generators Programming GuideProgramming the Status Register SystemStatus GroupsBaseband Operation Condition RegisterThe Baseband Op

Strona 105

Agilent Signal Generators Programming Guide 185Programming the Status Register SystemStatus GroupsBaseband Operation Event RegisterThe Baseband Operat

Strona 106

186 Agilent Signal Generators Programming GuideProgramming the Status Register SystemStatus GroupsData Questionable Condition RegisterThe Data Questio

Strona 107

Agilent Signal Generators Programming Guide 187Programming the Status Register SystemStatus GroupsTable 4-8 Data Questionable Condition Register BitsB

Strona 108

188 Agilent Signal Generators Programming GuideProgramming the Status Register SystemStatus GroupsData Questionable Transition Filters (negative and p

Strona 109

Agilent Signal Generators Programming Guide 189Programming the Status Register SystemStatus GroupsData Questionable Power Status GroupNOTE Some of the

Strona 110

190 Agilent Signal Generators Programming GuideProgramming the Status Register SystemStatus GroupsData Questionable Power Condition RegisterThe Data Q

Strona 111

Agilent Signal Generators Programming Guide 191Programming the Status Register SystemStatus GroupsData Questionable Power Event Enable RegisterThe Dat

Strona 112

Programming GuideNotices© Agilent Technologies, Inc. 2006 - 2010No part of this manual may be reproduced in any form or by any means (including elec-t

Strona 113

12 Agilent Signal Generators Programming GuideGetting Started with Remote OperationUsing the Web BrowserThe instrument can be accessed through a stand

Strona 114

192 Agilent Signal Generators Programming GuideProgramming the Status Register SystemStatus GroupsData Questionable Frequency Status GroupNOTE Some bi

Strona 115

Agilent Signal Generators Programming Guide 193Programming the Status Register SystemStatus GroupsData Questionable Frequency Condition RegisterThe Da

Strona 116

194 Agilent Signal Generators Programming GuideProgramming the Status Register SystemStatus GroupsData Questionable Frequency Event Enable RegisterLet

Strona 117

Agilent Signal Generators Programming Guide 195Programming the Status Register SystemStatus GroupsData Questionable Modulation Status GroupNOTE This s

Strona 118

196 Agilent Signal Generators Programming GuideProgramming the Status Register SystemStatus GroupsData Questionable Modulation Condition RegisterThe D

Strona 119

Agilent Signal Generators Programming Guide 197Programming the Status Register SystemStatus GroupsData Questionable Modulation Event Enable RegisterTh

Strona 120

198 Agilent Signal Generators Programming GuideProgramming the Status Register SystemStatus GroupsData Questionable Calibration Status GroupNOTE Some

Strona 121 - Figure 3-1

Agilent Signal Generators Programming Guide 199Programming the Status Register SystemStatus GroupsData Questionable Calibration Condition RegisterThe

Strona 122

200 Agilent Signal Generators Programming GuideProgramming the Status Register SystemStatus GroupsData Questionable Calibration Event Enable RegisterT

Strona 123

Agilent Signal Generators Programming Guide 201Programming the Status Register SystemStatus GroupsData Questionable BERT Status GroupNOTE This status

Strona 124 - VXI-11 Programming

Agilent Signal Generators Programming Guide 13Getting Started with Remote OperationUsing the Web BrowserModifying the Signal Generator ConfigurationNO

Strona 125

202 Agilent Signal Generators Programming GuideProgramming the Status Register SystemStatus GroupsData Questionable BERT Condition RegisterThe Data Qu

Strona 126

Agilent Signal Generators Programming Guide 203Programming the Status Register SystemStatus GroupsData Questionable BERT Event RegisterThe Data Questi

Strona 127

204 Agilent Signal Generators Programming GuideProgramming the Status Register SystemStatus Groups

Strona 128 - Sockets LAN Programming and C

Agilent Signal Generators Programming Guide 2055 Creating and Downloading Waveform FilesNOTE The ability to play externally created waveform data in t

Strona 129

206 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesOverview of Downloading and Extracting Waveform FilesOverview of

Strona 130

Agilent Signal Generators Programming Guide 207Creating and Downloading Waveform FilesUnderstanding Waveform DataWaveform Data RequirementsTo be succe

Strona 131 - Queries for Lan Using Sockets

208 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesUnderstanding Waveform DataThe maximum value for a single unsign

Strona 132

Agilent Signal Generators Programming Guide 209Creating and Downloading Waveform FilesUnderstanding Waveform DataNotice in the previous figure that th

Strona 133

210 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesUnderstanding Waveform DataByte SwappingWhile the processor for

Strona 134

Agilent Signal Generators Programming Guide 211Creating and Downloading Waveform FilesUnderstanding Waveform DataNotice that it takes only 15 bits (21

Strona 135

14 Agilent Signal Generators Programming GuideGetting Started with Remote OperationUsing the Web BrowserEnabling the Signal Generator Web ServerNOTE J

Strona 136

212 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesUnderstanding Waveform DataNOTE Whenever you interchange files b

Strona 137

Agilent Signal Generators Programming Guide 213Creating and Downloading Waveform FilesUnderstanding Waveform DataNOTE FIR filter capability is only av

Strona 138

214 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesUnderstanding Waveform DataNOTE The signal generator can accept

Strona 139

Agilent Signal Generators Programming Guide 215Creating and Downloading Waveform FilesWaveform StructureWaveform StructureTo play back waveforms, the

Strona 140

216 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesWaveform StructureThe following example shows a marker binary fi

Strona 141

Agilent Signal Generators Programming Guide 217Creating and Downloading Waveform FilesWaveform Phase ContinuityI/Q FileThe I/Q file contains the inter

Strona 142

218 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesWaveform Phase ContinuityAvoiding Phase DiscontinuitiesYou can e

Strona 143

Agilent Signal Generators Programming Guide 219Creating and Downloading Waveform FilesWaveform Phase ContinuityThe following figures illustrate the in

Strona 144

220 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesWaveform MemoryWaveform MemoryThe signal generator provides two

Strona 145

Agilent Signal Generators Programming Guide 221Creating and Downloading Waveform FilesWaveform MemoryThe following figure on Figure 5- 1 on page 222 s

Strona 146

Agilent Signal Generators Programming Guide 15Getting Started with Remote OperationUsing the Web Browser3. In the web browser address field, enter the

Strona 147

222 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesWaveform MemoryFigure 5-1Memory AllocationVolatile MemoryThe sig

Strona 148

Agilent Signal Generators Programming Guide 223Creating and Downloading Waveform FilesWaveform MemoryAs shown in the examples, waveforms can cause the

Strona 149

224 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesWaveform MemoryFor more information on default cluster sizes for

Strona 150

Agilent Signal Generators Programming Guide 225Creating and Downloading Waveform FilesWaveform MemoryVolatile and Non–Volatile Memory (N5162A/82A)Vola

Strona 151

226 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesCommands for Downloading and Extracting Waveform DataCommands fo

Strona 152

Agilent Signal Generators Programming Guide 227Creating and Downloading Waveform FilesCommands for Downloading and Extracting Waveform DataEncrypted I

Strona 153

228 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesCommands for Downloading and Extracting Waveform DataSCPI Comman

Strona 154

Agilent Signal Generators Programming Guide 229Creating and Downloading Waveform FilesCommands for Downloading and Extracting Waveform DataTable 5-7 D

Strona 155

230 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesCommands for Downloading and Extracting Waveform DataSCPI/non–vo

Strona 156

Agilent Signal Generators Programming Guide 231Creating and Downloading Waveform FilesCommands for Downloading and Extracting Waveform DataTable 5-11

Strona 157

16 Agilent Signal Generators Programming GuideGetting Started with Remote OperationUsing the Web BrowserFTP enables the transfer of files between the

Strona 158

232 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesCommands for Downloading and Extracting Waveform DataFTP Procedu

Strona 159

Agilent Signal Generators Programming Guide 233Creating and Downloading Waveform FilesCommands for Downloading and Extracting Waveform DataCAUTION Get

Strona 160 - Before Using the Examples

234 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesCommands for Downloading and Extracting Waveform DataTo get a fi

Strona 161

Agilent Signal Generators Programming Guide 235Creating and Downloading Waveform FilesCreating Waveform DataCreating Waveform DataThis section examine

Strona 162

236 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesCreating Waveform DataLine Code—Create I and Q data1234567891011

Strona 163

Agilent Signal Generators Programming Guide 237Creating and Downloading Waveform FilesCreating Waveform Data7–11 Create a loop to do the following:• G

Strona 164

238 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesCreating Waveform Data2. Save the I/Q data to a text file to rev

Strona 165

Agilent Signal Generators Programming Guide 239Creating and Downloading Waveform FilesCreating Waveform DataLine Code—Interleaving and Byte Swapping f

Strona 166

240 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesCreating Waveform Data21–29 the I and Q data), and interleave th

Strona 167 - Overview

Agilent Signal Generators Programming Guide 241Creating and Downloading Waveform FilesDownloading Waveform DataTo download the data created in the abo

Strona 168

Agilent Signal Generators Programming Guide 17Getting Started with Remote OperationUsing the Web BrowserLAN Configuration System Defaults (Agilent MXG

Strona 169

242 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesDownloading Waveform DataFor advanced programming languages, thi

Strona 170

Agilent Signal Generators Programming Guide 243Creating and Downloading Waveform FilesDownloading Waveform Data2. Download the I/Q dataThe following c

Strona 171

244 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesDownloading Waveform DataUsing Advanced Programming LanguagesThi

Strona 172

Agilent Signal Generators Programming Guide 245Creating and Downloading Waveform FilesDownloading Waveform Data2. Download the I/Q data.The following

Strona 173

246 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesDownloading Waveform Data9 Calculate the total number of bytes,

Strona 174

Agilent Signal Generators Programming Guide 247Creating and Downloading Waveform FilesLoading, Playing, and Verifying a Downloaded WaveformLoading, Pl

Strona 175

248 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesLoading, Playing, and Verifying a Downloaded WaveformNOTE When y

Strona 176 - Status Register Bit Values

Agilent Signal Generators Programming Guide 249Creating and Downloading Waveform FilesLoading, Playing, and Verifying a Downloaded WaveformVerifying t

Strona 177 - Deciding How to Monitor

250 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesUsing the Download Utilities1. List the waveform files from the

Strona 178

Agilent Signal Generators Programming Guide 251Creating and Downloading Waveform FilesDownloading E443xB Signal Generator FilesNOTE Agilent Intuilink

Strona 179 - Status Register SCPI Commands

18 Agilent Signal Generators Programming GuideGetting Started with Remote OperationUsing the Web BrowserDisplaying the LAN Configuration Summary (Agil

Strona 180

252 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesDownloading E443xB Signal Generator FilesE443xB Data FormatThe f

Strona 181

Agilent Signal Generators Programming Guide 253Creating and Downloading Waveform FilesDownloading E443xB Signal Generator Files• Creates a marker file

Strona 182

254 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming ExamplesSCPI CommandsUse the following commands to d

Strona 183 - Status Byte Group

Agilent Signal Generators Programming Guide 255Creating and Downloading Waveform FilesProgramming ExamplesC++ Programming ExamplesThis section contain

Strona 184 - Status Byte Register

256 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming Examples{ // 1.) Create Simple IQ Signal **********

Strona 185 - Status Groups

Agilent Signal Generators Programming Guide 257Creating and Downloading Waveform FilesProgramming Examples // For this reason the data bytes are swap

Strona 186 - Standard Event Status Group

258 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming Examples // Save the data to a file // Use FTP or

Strona 187

Agilent Signal Generators Programming Guide 259Creating and Downloading Waveform FilesProgramming ExamplesCreating and Storing I/Q Data—Little Endian

Strona 188

260 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming Examples for (int i=0; i<SAMPLES; ++i) {

Strona 189 - STATus:OPERation:CONDition?

Agilent Signal Generators Programming Guide 261Creating and Downloading Waveform FilesProgramming Examples#include <stdlib.h>#include <stdio.

Strona 190

Agilent Signal Generators Programming Guide 19Getting Started with Remote OperationPreferencesPreferencesThe following commonly- used manual command s

Strona 191

262 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming Examples // spreadsheet to help spot any problems

Strona 192

Agilent Signal Generators Programming Guide 263Creating and Downloading Waveform FilesProgramming Examples { fprintf(stderr, “iopen failed (

Strona 193

264 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming ExamplesImporting and Downloading I/Q Data—Big Endia

Strona 194

Agilent Signal Generators Programming Guide 265Creating and Downloading Waveform FilesProgramming Examples if( fseek( file, 0, SEEK_END ) <

Strona 195

266 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming Examples fprintf(stderr, "Could not allo

Strona 196

Agilent Signal Generators Programming Guide 267Creating and Downloading Waveform FilesProgramming Examples// as needed. //****************************

Strona 197

268 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming Examplesreturn 0; } if( fseek( file, 0, SE

Strona 198

Agilent Signal Generators Programming Guide 269Creating and Downloading Waveform FilesProgramming Examples viWrite(vi, s2, strlen((char*)s2), 0

Strona 199 - Register) to 1

270 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming ExamplesImporting, Byte Swapping, Interleaving, and

Strona 200

Agilent Signal Generators Programming Guide 271Creating and Downloading Waveform FilesProgramming Examples // This is a text file to which we will

Strona 201

20 Agilent Signal Generators Programming GuideGetting Started with Remote OperationPreferencesConfiguring the Display for Remote Command Setups (ESG/P

Strona 202

272 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming Examples while(!done) { i1 = fgetc(infi

Strona 203

Agilent Signal Generators Programming Guide 273Creating and Downloading Waveform FilesProgramming Examples if (outfile==NULL) perror (“Error openin

Strona 204

274 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming Examples // 0 gives 0 V output // 32

Strona 205 - Condition Register) to 1

Agilent Signal Generators Programming Guide 275Creating and Downloading Waveform FilesProgramming Examples // The SCPI command has four parts. /

Strona 206

276 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming Examples iwrite(id, iqbuffer, bytesToSend, 0, 0);

Strona 207

Agilent Signal Generators Programming Guide 277Creating and Downloading Waveform FilesProgramming Examples unsigned mag_squared; double rmsDac;

Strona 208 - Condition register) to 1

278 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming Examples% 2.) Save the waveform into the ESG/PSG Int

Strona 209

Agilent Signal Generators Programming Guide 279Creating and Downloading Waveform FilesProgramming Examples%[Iwave;Qwave];%waveform = waveform(:)'

Strona 210 - *RST sets this bit to zero

280 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming Examplesif FID == -1 error('Cannot Open File&ap

Strona 211

Agilent Signal Generators Programming Guide 281Creating and Downloading Waveform FilesProgramming ExamplesCreating and Downloading a PulseNOTE This se

Strona 212

Agilent Signal Generators Programming Guide 21Getting Started with Remote OperationPreferencesSetting the Help Mode (ESG/PSG)For details on each key,

Strona 213

282 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming Examples% arrange the i–samples and scale the amplit

Strona 214

Agilent Signal Generators Programming Guide 283Creating and Downloading Waveform FilesProgramming Examples[status, status_description] = agt_sendcomma

Strona 215 - Understanding Waveform Data

284 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming ExamplesNOTE For the Agilent MXG, the SOURce:FREQuen

Strona 216 - LSB and MSB (Bit Order)

Agilent Signal Generators Programming Guide 285Creating and Downloading Waveform FilesProgramming Examples% Copyright 2009 Agilent Technologies Inc.%%

Strona 217 - 1 1 1 0 1 0 0 1

286 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming Examples end if length(iqWave)<60 er

Strona 218 - DAC Input Values

Agilent Signal Generators Programming Guide 287Creating and Downloading Waveform FilesProgramming Examples WriteData(t,mkrData,1,bufSize); fprin

Strona 219

288 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming Examplesendfunction [data, rms] = FormatWaveform( iq

Strona 220

Agilent Signal Generators Programming Guide 289Creating and Downloading Waveform FilesProgramming Examples mkr = mkr + 8*(markers(4,:)~=0);

Strona 221 - I and Q Interleaving

290 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming Examples hdrCmd = ['RADio:ARB:HEAD:WRIT &quo

Strona 222

Agilent Signal Generators Programming Guide 291Creating and Downloading Waveform FilesProgramming Examples% Copyright 2009 Agilent Technologies Inc.%%

Strona 223 - Waveform Structure

Contents iii1 Getting Started with Remote OperationProgramming and Software/Hardware Layers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 224

22 Agilent Signal Generators Programming GuideGetting Started with Remote OperationTroubleshootingTroubleshootingIn each section of this document, the

Strona 225 - Waveform Phase Continuity

292 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming ExamplesVisual Basic Programming ExamplesCreating I/

Strona 226

Agilent Signal Generators Programming Guide 293Creating and Downloading Waveform FilesProgramming ExamplesAMPLITUDE = 32767 ' Scale the amp

Strona 227

294 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming ExamplesOn Error GoTo file_error For ind

Strona 228 - Waveform Memory

Agilent Signal Generators Programming Guide 295Creating and Downloading Waveform FilesProgramming Examples' data requirements for file downloads.

Strona 229

296 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming ExamplesFileHandle = FreeFile()On Error GoTo errorha

Strona 230 - Memory Allocation

Agilent Signal Generators Programming Guide 297Creating and Downloading Waveform FilesProgramming ExamplesHP Basic Programming ExamplesThis section co

Strona 231

298 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming Examples170 Ndigits$=VAL$(Ndigits)180 WAIT 1190

Strona 232 - Memory Size

Agilent Signal Generators Programming Guide 299Creating and Downloading Waveform FilesProgramming ExamplesCreating and Downloading Waveform Data Using

Strona 233

300 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming Examples210 OUTPUT @PSG USING "#,K";Nbyt

Strona 234 - Waveform Data Encryption

Agilent Signal Generators Programming Guide 301Creating and Downloading Waveform FilesProgramming ExamplesCreating and Downloading E443xB Waveform Dat

Strona 235 - File Transfer Methods

Agilent Signal Generators Programming Guide 23Getting Started with Remote OperationError MessagesError MessagesIf an error condition occurs in the sig

Strona 236 - SCPI Command Line Structure

302 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesProgramming Examples190 OUTPUT @Esgb;Iwfm_data(*)200 OUTPUT

Strona 237

Agilent Signal Generators Programming Guide 303Creating and Downloading Waveform FilesProgramming Examples10 ! RE-SAVE "ARB_IQ_file"20

Strona 238

304 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesTroubleshooting Waveform FilesTroubleshooting Waveform Files 80:

Strona 239

Agilent Signal Generators Programming Guide 305Creating and Downloading Waveform FilesTroubleshooting Waveform FilesConfiguring the Pulse/RF Blank (Ag

Strona 240 - FTP Procedures

306 Agilent Signal Generators Programming GuideCreating and Downloading Waveform FilesTroubleshooting Waveform Files

Strona 241

Agilent Signal Generators Programming Guide 3076 Creating and Downloading User–Data FilesNOTE Some features apply to only the E4438C with Option 001,

Strona 242

308 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesOverviewOverviewUser data is a generic term for various data ty

Strona 243 - Creating Waveform Data

Agilent Signal Generators Programming Guide 309Creating and Downloading User–Data FilesSignal Generator MemorySignal Generator MemoryThe signal genera

Strona 244

310 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesSignal Generator MemoryThe following figure shows the signal ge

Strona 245

Agilent Signal Generators Programming Guide 311Creating and Downloading User–Data FilesSignal Generator MemoryMemory AllocationVolatile MemoryThe sign

Strona 246

24 Agilent Signal Generators Programming GuideGetting Started with Remote OperationError MessagesError Message TypesEvents generate only one type of e

Strona 247

312 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesSignal Generator Memory(see table on page 312). For example, r

Strona 248

Agilent Signal Generators Programming Guide 313Creating and Downloading User–Data FilesSignal Generator MemoryChecking Available MemoryWhenever you do

Strona 249 - Downloading Waveform Data

314 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesSignal Generator MemoryBit and binary files increase in size wh

Strona 250 - Using Simulation Software

Agilent Signal Generators Programming Guide 315Creating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)User F

Strona 251

316 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)You do

Strona 252

Agilent Signal Generators Programming Guide 317Creating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)on the

Strona 253

318 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)Even t

Strona 254

Agilent Signal Generators Programming Guide 319Creating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)Binary

Strona 255

320 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)Framed

Strona 256 - Playing the Waveform

Agilent Signal Generators Programming Guide 321Creating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)PRAM.

Strona 257 - Verifying the Waveform

Agilent Signal Generators Programming Guide 252 Using IO InterfacesNOTE For the N5161A/62A the softkey menus and features mentioned in this chapter a

Strona 258 - Using the Download Utilities

322 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)Calcul

Strona 259

Agilent Signal Generators Programming Guide 323Creating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)AUTOGE

Strona 260 - E443xB Data Format

324 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)8. Rou

Strona 261 - Marker 3 and 4 bits

Agilent Signal Generators Programming Guide 325Creating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)C th

Strona 262

326 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)Line C

Strona 263 - C++ Programming Examples

Agilent Signal Generators Programming Guide 327Creating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)Comman

Strona 264

328 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)Comman

Strona 265

Agilent Signal Generators Programming Guide 329Creating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)File N

Strona 266

330 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)2. Sel

Strona 267

Agilent Signal Generators Programming Guide 331Creating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)Modify

Strona 268

26 Agilent Signal Generators Programming GuideUsing IO InterfacesUsing GPIBInterfaceTypeOperatingSystemIO Library Languages Backplane/BUSMax IO(kB/sec

Strona 269

332 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)There

Strona 270

Agilent Signal Generators Programming Guide 333Creating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)• <

Strona 271

334 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)data.

Strona 272

Agilent Signal Generators Programming Guide 335Creating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)1 3 46

Strona 273

336 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)Event

Strona 274

Agilent Signal Generators Programming Guide 337Creating and Downloading User–Data FilesUser File Data (Bit/Binary) Downloads (E4438C and E8267D)Real–T

Strona 275

338 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesPattern RAM (PRAM) Data Downloads (E4438C and E8267D)Pattern RA

Strona 276

Agilent Signal Generators Programming Guide 339Creating and Downloading User–Data FilesPattern RAM (PRAM) Data Downloads (E4438C and E8267D)PRAM files

Strona 277

340 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesPattern RAM (PRAM) Data Downloads (E4438C and E8267D)As seen in

Strona 278

Agilent Signal Generators Programming Guide 341Creating and Downloading User–Data FilesPattern RAM (PRAM) Data Downloads (E4438C and E8267D)Viewing th

Strona 279

Agilent Signal Generators Programming Guide 27Using IO InterfacesUsing GPIBSet Up the GPIB InterfaceFor the Agilent MXG refer to the Figure 2- 1 and f

Strona 280

342 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesPattern RAM (PRAM) Data Downloads (E4438C and E8267D)PRAM File

Strona 281

Agilent Signal Generators Programming Guide 343Creating and Downloading User–Data FilesPattern RAM (PRAM) Data Downloads (E4438C and E8267D)Minimum Fi

Strona 282

344 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesPattern RAM (PRAM) Data Downloads (E4438C and E8267D)SCPI Comma

Strona 283

Agilent Signal Generators Programming Guide 345Creating and Downloading User–Data FilesPattern RAM (PRAM) Data Downloads (E4438C and E8267D)Command Sy

Strona 284

346 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesPattern RAM (PRAM) Data Downloads (E4438C and E8267D)Line Code—

Strona 285 - MATLAB Programming Examples

Agilent Signal Generators Programming Guide 347Creating and Downloading User–Data FilesPattern RAM (PRAM) Data Downloads (E4438C and E8267D)Selecting

Strona 286

348 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesPattern RAM (PRAM) Data Downloads (E4438C and E8267D)5. Turn th

Strona 287

Agilent Signal Generators Programming Guide 349Creating and Downloading User–Data FilesPattern RAM (PRAM) Data Downloads (E4438C and E8267D)Extracting

Strona 288

350 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesPattern RAM (PRAM) Data Downloads (E4438C and E8267D)Command Sy

Strona 289

Agilent Signal Generators Programming Guide 351Creating and Downloading User–Data FilesPattern RAM (PRAM) Data Downloads (E4438C and E8267D)There are

Strona 290

28 Agilent Signal Generators Programming GuideUsing IO InterfacesUsing GPIBFigure 2-2 Setting the GPIB Address on the ESG/PSGConnect a GPIB interface

Strona 291

352 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesFIR Filter Coefficient Downloads (N5162A, N5182A, E4438C and E8

Strona 292

Agilent Signal Generators Programming Guide 353Creating and Downloading User–Data FilesFIR Filter Coefficient Downloads (N5162A, N5182A, E4438C and E8

Strona 293

354 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesFIR Filter Coefficient Downloads (N5162A, N5182A, E4438C and E8

Strona 294

Agilent Signal Generators Programming Guide 355Creating and Downloading User–Data FilesFIR Filter Coefficient Downloads (N5162A, N5182A, E4438C and E8

Strona 295

356 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesUsing the Equalization Filter (N5162A and N5182A with Options 6

Strona 296

Agilent Signal Generators Programming Guide 357Creating and Downloading User–Data FilesSave and Recall Instrument State FilesSave and Recall Instrumen

Strona 297

358 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesSave and Recall Instrument State FilesThe recall function recal

Strona 298

Agilent Signal Generators Programming Guide 359Creating and Downloading User–Data FilesSave and Recall Instrument State FilesPerform the following ste

Strona 299

360 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesSave and Recall Instrument State Files// The Agilent VISA libra

Strona 300

Agilent Signal Generators Programming Guide 361Creating and Downloading User–Data FilesSave and Recall Instrument State Filesbool quit = false;while (

Strona 301

Agilent Signal Generators Programming Guide 29Using IO InterfacesGPIB Programming Interface ExamplesGPIB Interface TermsAn instrument that is part of

Strona 302

362 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesSave and Recall Instrument State Filesthe local directory (iden

Strona 303

Agilent Signal Generators Programming Guide 363Creating and Downloading User–Data FilesSave and Recall Instrument State Filesstring catalog = ReadDevi

Strona 304

364 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesSave and Recall Instrument State Filesstring retValue = "&

Strona 305 - HP Basic Programming Examples

Agilent Signal Generators Programming Guide 365Creating and Downloading User–Data FilesSave and Recall Instrument State FilesNOT appended to the block

Strona 306

366 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesSave and Recall Instrument State Files LoadConfig = 4

Strona 307

Agilent Signal Generators Programming Guide 367Creating and Downloading User–Data FilesSave and Recall Instrument State Files [DllImport("

Strona 308

368 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesUser Flatness Correction Downloads Using C++ and VISAUser Flatn

Strona 309

Agilent Signal Generators Programming Guide 369Creating and Downloading User–Data FilesUser Flatness Correction Downloads Using C++ and VISA//********

Strona 310

370 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesUser Flatness Correction Downloads Using C++ and VISA if (st

Strona 311

Agilent Signal Generators Programming Guide 371Creating and Downloading User–Data FilesUser Flatness Correction Downloads Using C++ and VISA{sprintf((

Strona 312

30 Agilent Signal Generators Programming GuideUsing IO InterfacesGPIB Programming Interface Examples170 LOCAL Sig_gen ! Places the signal generator

Strona 313 - Mode Setup

372 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesData Transfer Troubleshooting (N5162A, N5182A, E4438C and E8267

Strona 314

Agilent Signal Generators Programming Guide 373Creating and Downloading User–Data FilesData Transfer Troubleshooting (N5162A, N5182A, E4438C and E8267

Strona 315

374 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesData Transfer Troubleshooting (N5162A, N5182A, E4438C and E8267

Strona 316

Agilent Signal Generators Programming Guide 375Creating and Downloading User–Data FilesData Transfer Troubleshooting (N5162A, N5182A, E4438C and E8267

Strona 317 - Signal Generator Memory

376 Agilent Signal Generators Programming GuideCreating and Downloading User–Data FilesData Transfer Troubleshooting (N5162A, N5182A, E4438C and E8267

Strona 318

377IndexSymbols.NET framework, 357Numerics2’s complement data format, 2138757dGPIB addresses, 114pass- thru commands, 113pass- thru programming, 114A

Strona 319

378 Indexgenerating externally applied, 95CW signals, generating, 93data questionablestatus register, reading, 105FM signals, generating internally a

Strona 320

379Indexcalibration event enable, 200condition, 186event, 188event enable, 188frequency condition, 193frequency event, 193frequency event enable, 194

Strona 321 - Checking Available Memory

380 Indexdescription, 177event registersdescription, 177example programs See programming examples, 254examplespass- thru commands, 113save and recall

Strona 322

381Indexhelp modesettingAgilent mxg, 20esg, 21psg, 21hex editorbinary file, modifying, 330bit file, modifying, 331hexadecimal data, 292hostname, 32,

Strona 323

Agilent Signal Generators Programming Guide 31Using IO InterfacesUsing LANUsing LAN The Agilent MXG is capable of 100Base–T LAN communication. The ESG

Strona 324 - Bit File Type Data

382 IndexJavaexample, 76, 143Kkjkj, 223LLabView, 11LANAuto- IP configuration, 35config, 40configurationAgilent mxg, 34, 35esg/psg, 34menu, Agilent mx

Strona 325 - Start block data

383Indexflatness, 313instrument state, 313PRAM, 313locations, 220, 309non- volatile (NVWFM), 227signal generator, maximum, 313size, 224, 312volatile

Strona 326

384 Indexcommand syntax, for restoring, 348command syntax, for storing, 348extracting, 349modifying, 351non- volatile memory, storing, 348understandi

Strona 327 - Binary File Type Data

385Indexecho, setting, 63format parameters, 66HP Basic, using queries, 68, 155interface, 63interfaces, 3IO libraries, 62overview, 61program examples,

Strona 328 - User File Size

386 Indexregister, 179standard operationcondition register, 181event enable register, 182event register, 182transition filters, 182state files, 357st

Strona 329

387IndexIO libraries, 70setting up, 70using, Agilent mxg, 69verifying operation, 71usb mediafile extensions, 223user datafile, modifying, 330files, c

Strona 330

388 Indexfile, encryption, 227memory allocation, 222Agilent esg, 311Agilent psg, 311securewave directory, 227memory, volatile (WFM1), 227signal gener

Strona 331

Contents ivUsing Telnet LAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Using FTP . . . . . .

Strona 332 - Downloading User Files

32 Agilent Signal Generators Programming GuideUsing IO InterfacesUsing LANSetting Up the LAN InterfaceFor LAN operation, the signal generator must be

Strona 333

Agilent Signal Generators Programming Guide 33Using IO InterfacesUsing LANConfiguring the VXI–11 for LAN (ESG/PSG)Manual ConfigurationThe Hostname so

Strona 334

34 Agilent Signal Generators Programming GuideUsing IO InterfacesUsing LANManually Configuring the Agilent MXG LAN Manually Configuring the ESG/PSG LA

Strona 335

Agilent Signal Generators Programming Guide 35Using IO InterfacesUsing LANDHCP ConfigurationIf the DHCP server uses dynamic DNS to link the hostname w

Strona 336

36 Agilent Signal Generators Programming GuideUsing IO InterfacesUsing LANConfiguring the DHCP LAN (ESG/PSG)Setting up Private LAN You can connect the

Strona 337

Agilent Signal Generators Programming Guide 37Using IO InterfacesUsing LANFrom a UNIX® workstation, type (UNIX is a registered trademark of the Open G

Strona 338 - Modifying User File Data

38 Agilent Signal Generators Programming GuideUsing IO InterfacesUsing LANinstrument will use the default IP address value and the others will have ra

Strona 339

Agilent Signal Generators Programming Guide 39Using IO InterfacesUsing LANNOTE The following sections are specific to Agilent IO Libraries versions M

Strona 340

40 Agilent Signal Generators Programming GuideUsing IO InterfacesUsing LANUsing VISA AssistantUse the VISA Assistant, available with the Agilent IO Li

Strona 341

Agilent Signal Generators Programming Guide 41Using IO InterfacesUsing LANFigure 2-3 IO Config Form (Windows NT)Check to see that the Default Protocol

Strona 342

Contents vQueries for GPIB Using VISA and C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91Generating a CW Signal Using VI

Strona 343 - 2499 only)

42 Agilent Signal Generators Programming GuideUsing IO InterfacesUsing LANUsing VXI–11 The signal generator supports the LAN interface protocol descri

Strona 344

Agilent Signal Generators Programming Guide 43Using IO InterfacesUsing LANFigure 2-4 Show Devices Form (Agilent IO Library version J.01.0100)Using Soc

Strona 345

44 Agilent Signal Generators Programming GuideUsing IO InterfacesUsing LANBefore you can use sockets LAN, you must select the signal generator’s socke

Strona 346

Agilent Signal Generators Programming Guide 45Using IO InterfacesUsing LAN2. At the command prompt, type in telnet.3. Press the Enter key. The Telnet

Strona 347 - Understanding PRAM Files

46 Agilent Signal Generators Programming GuideUsing IO InterfacesUsing LANFigure 2-6 Telnet Window (Windows 2000)Using Telnet On Windows 20001. On you

Strona 348

Agilent Signal Generators Programming Guide 47Using IO InterfacesUsing LANFigure 2-7 Telnet 2000 WindowThe Standard UNIX Telnet CommandSynopsistelnet

Strona 349 - Viewing the PRAM Waveform

48 Agilent Signal Generators Programming GuideUsing IO InterfacesUsing LANUnix Telnet ExampleTo connect to the instrument with host name myInstrument

Strona 350 - PRAM File Size

Agilent Signal Generators Programming Guide 49Using IO InterfacesUsing LANFigure 2-8 FTP Screen The following steps outline a sample FTP session from

Strona 351

50 Agilent Signal Generators Programming GuideUsing IO InterfacesUsing LANUsing LXINOTE Full LXI–B feature implementation is only available on instrum

Strona 352

Agilent Signal Generators Programming Guide 51Using IO InterfacesUsing LANVerifying Time SynchronizationTo verify that both instruments are running PT

Strona 353

Contents viStandard Event Status Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178Standard Operation Status Gr

Strona 354

52 Agilent Signal Generators Programming GuideUsing IO InterfacesUsing LANPeer to Peer MessagingThe MXA and MXG are capable of sending and receiving L

Strona 355

Agilent Signal Generators Programming Guide 53Using IO InterfacesUsing LANUsing the Front Panel to Configure LXI EventsThe MXG can be configured to se

Strona 356

54 Agilent Signal Generators Programming GuideUsing IO InterfacesUsing LANUsing the front panel to configure an LXI Trigger on the MXG The MXG is capa

Strona 357 - Extracting a PRAM File

Agilent Signal Generators Programming Guide 55Using IO InterfacesUsing LAN4. Monitor Response as on page 53.This may be done assuming that the Output

Strona 358

56 Agilent Signal Generators Programming GuideUsing IO InterfacesUsing LANThe MXA receives the LAN0 event and triggers. The MXA's Waiting For Tri

Strona 359 - Modifying PRAM Files

Agilent Signal Generators Programming Guide 57Using IO InterfacesUsing LAN8. Sets the MXG how the lists will be entered:Send the following SCPI comman

Strona 360 - Data Requirements

58 Agilent Signal Generators Programming GuideUsing IO InterfacesUsing LAN17. Disable LXI Output LAN Events on the MXA:Send the following SCPI command

Strona 361 - Data Limitations

Agilent Signal Generators Programming Guide 59Using IO InterfacesUsing LAN25. Make sure the MXA's LXI LAN triggers are disabled:Send the followin

Strona 362

60 Agilent Signal Generators Programming GuideUsing IO InterfacesUsing LAN33. Send the MXG a "LAN1" peer to peer message:Using Interactive

Strona 363

Agilent Signal Generators Programming Guide 61Using IO InterfacesUsing RS–232 (ESG and PSG Only)For More InformationFor more information on using LXI

Strona 364

Contents viiDownloading Waveform Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241Using Simulation Softw

Strona 365 - Save and Recall SCPI Commands

62 Agilent Signal Generators Programming GuideUsing IO InterfacesUsing RS–232 (ESG and PSG Only)The following sections contain information on selectin

Strona 366

Agilent Signal Generators Programming Guide 63Using IO InterfacesUsing RS–232 (ESG and PSG Only)Setting Up the RS–232 Interface1. Setting the RS–232 I

Strona 367

64 Agilent Signal Generators Programming GuideUsing IO InterfacesUsing RS–232 (ESG and PSG Only)2. Setting the RS–232 Echo Softkey3. Connect an RS–232

Strona 368

Agilent Signal Generators Programming Guide 65Using IO InterfacesUsing RS–232 (ESG and PSG Only)Verifying RS–232 FunctionalityYou can use the HyperTer

Strona 369

66 Agilent Signal Generators Programming GuideUsing IO InterfacesRS–232 Programming Interface ExamplesCharacter Format ParametersThe signal generator

Strona 370

Agilent Signal Generators Programming Guide 67Using IO InterfacesRS–232 Programming Interface ExamplesInterface Check Using HP BASIC This portion of t

Strona 371

68 Agilent Signal Generators Programming GuideUsing IO InterfacesRS–232 Programming Interface ExamplesQueries Using HP Basic and RS–232This portion of

Strona 372

Agilent Signal Generators Programming Guide 69Using IO InterfacesUsing USB (Agilent MXG)Using USB (Agilent MXG)CAUTION USB cables are not industrial g

Strona 373

70 Agilent Signal Generators Programming GuideUsing IO InterfacesUsing USB (Agilent MXG)Selecting I/O Libraries for USB CAUTION The Agilent MXG’s USB

Strona 374

Agilent Signal Generators Programming Guide 71Using IO InterfacesUsing USB (Agilent MXG)Front Panel USB (Type–A)For details on using the front panel U

Strona 375

Contents viiiUnderstanding Framed Transmission For Real–Time TDMA . . . . . . . . . . . . . . . . . . . . 333Real–Time Custom High Data Rates. . . . .

Strona 376

72 Agilent Signal Generators Programming GuideUsing IO InterfacesUsing USB (Agilent MXG)

Strona 377

Agilent Signal Generators Programming Guide 733 Programming ExamplesNOTE For the N5161A/62A the softkey menus and features mentioned in this chapter

Strona 378

74 Agilent Signal Generators Programming GuideProgramming ExamplesUsing the Programming Interface ExamplesUpdate in Remote function. (For more informa

Strona 379

Agilent Signal Generators Programming Guide 75Programming ExamplesUsing the Programming Interface ExamplesC/C++ Examples• “Interface Check for GPIB Us

Strona 380 - User File Download Problems

76 Agilent Signal Generators Programming GuideProgramming ExamplesUsing the Programming Interface ExamplesNOTE If you want to use VISA functions such

Strona 381 - PRAM Download Problems

Agilent Signal Generators Programming Guide 77Programming ExamplesUsing GPIBRunning MATLAB ExamplesFor information regarding programming examples and

Strona 382

78 Agilent Signal Generators Programming GuideProgramming ExamplesGPIB Programming Interface ExamplesGPIB Programming Interface Examples• “Interface C

Strona 383

Agilent Signal Generators Programming Guide 79Programming ExamplesGPIB Programming Interface ExamplesRemote FunctionThe HP Basic function REMOTE and t

Strona 384

80 Agilent Signal Generators Programming GuideProgramming ExamplesGPIB Programming Interface ExamplesLocal FunctionThe HP Basic function LOCAL and the

Strona 385 - Numerics

Agilent Signal Generators Programming Guide 81Programming ExamplesGPIB Programming Interface ExamplesOutput FunctionThe HP Basic IO function OUTPUT an

Strona 386

Agilent Signal Generators Programming Guide 11 Getting Started with Remote OperationCAUTION Agilent does not recommend going backwards in firmware ve

Strona 387

82 Agilent Signal Generators Programming GuideProgramming ExamplesGPIB Programming Interface ExamplesEnter Function The HP Basic function ENTER reads

Strona 388

Agilent Signal Generators Programming Guide 83Programming ExamplesGPIB Programming Interface Examples140 !******************************************

Strona 389

84 Agilent Signal Generators Programming GuideProgramming ExamplesGPIB Programming Interface ExamplesAddr4882_t Address[31]; // Declares an array of t

Strona 390

Agilent Signal Generators Programming Guide 85Programming ExamplesGPIB Programming Interface Examples{ViSession defaultRM, vi; // Declares a va

Strona 391

86 Agilent Signal Generators Programming GuideProgramming ExamplesGPIB Programming Interface Examples110 ! Local, control.120

Strona 392

Agilent Signal Generators Programming Guide 87Programming ExamplesGPIB Programming Interface Examples// PROGRAM NAME: niex2.cpp//// PROGRAM DESCRIPTIO

Strona 393

88 Agilent Signal Generators Programming GuideProgramming ExamplesGPIB Programming Interface ExamplesQueries Using HP Basic and GPIBThis example demon

Strona 394

Agilent Signal Generators Programming Guide 89Programming ExamplesGPIB Programming Interface Examples340 OUTPUT Sig_gen;"OUTP OFF" ! Tur

Strona 395

90 Agilent Signal Generators Programming GuideProgramming ExamplesGPIB Programming Interface Examples// a query.////**********************************

Strona 396

Agilent Signal Generators Programming Guide 91Programming ExamplesGPIB Programming Interface Examples ibwrt(sig, "OUTP?",5); // Q

Komentarze do niniejszej Instrukcji

Brak uwag