2
Visit Agilent Technologies’ worldwide websites (
http://
www.agilent.com/find/vxi
or
http://www.agilent.com/find/
tmdir
) to review the following E8408A example
applications:
Appliance manufacture
Battery manufacture
Cable and wire test
Canning process characterization
Crystal oscillator manufacture
Design verification using environmental chambers
Energy conservation
Elevator test
Race car test
Switch box in Electronic Functional Test
Wastewater treatment/test
175 Watts Usable Power
The E8408A provides 175 watts usable power. This is
adequate to power the vast majority of Agilent VXI modules.
Superior Cooling
The E8408A’s innovative mechanical design provides
extremely quiet and efficient cooling for the power supply
and modules. Carefully engineered airflow provides
excellent cooling with minimum acoustic noise.
A two-speed cooling fan provides reliable cooling of the
power supply and modules. The fan operates in either
Variable (automatically controlled) or Full Speed mode. A
two-position switch on the mainframe’s front panel controls
the speed mode. Full Speed mode is recommended for
maximum cooling when acoustic noise is not a big concern.
In Variable Speed mode, the fan speed is controlled
automatically as a function of temperature rise in the
mainframe and ambient temperature. Variable Speed mode
allows the quietest operation while providing sufficient
power supply and module cooling.
Airflow enters the mainframe rear panel, flows through the
power supply, fan and modules and exhausts out the left
side (as viewed from the front with the E8408A in
horizontal position). This allows mainframes to be stacked
or rack-mounted directly on top of one another.
At-a-Glance Confidence in Operation
The E8408A front panel indicator lights give up-to-the-
moment visual indication that power supply voltages are
operational, the power supply temperature is within limits,
and the fan is operational.
Improved, Highly Reliable Backplane Design
The backplane features solid state automatic daisy-chain
jumpering for the VMEbus grant and interrupt acknowledge
lines, eliminating the need for hand selection of switch
settings. Full differential distribution of the CLK10 signal is
provided on the backplane. This minimizes jitter and skew,
providing a clean timing source for VXI instrument
modules. The surface mount backplane improves both
reliability and stripline signal performance.
Agilent generates SYSRESET and ACFAIL on the backplane.
This is necessary for full compliance with the VXI
Specification, but is not generally implemented by other
manufacturers.
Easy Maintenance Power Supply
Convenient access to the power supply and cooling fan is
provided through the mainframe’s rear panel. A
replacement power supply and fan can be installed without
removing the mainframe from your rack. The power
supply’s plug-in design makes replacement easy.
Backplane Connector Shields Kit
The E8408A Opt 918 improves ground connections between
VXI modules and the E8408A backplane. A few Agilent VXI
modules require these shields to comply with EMC EN55011
and CISPR11. (The vast majority of Agilent VXI modules do
not require these shields.) Note that the shields are only
useful if VXI modules include contacts that conform to VXI
Spec. B.7.2.3.
Rack Mount/Cable Route Kit
The E8397A Rack Mount Adapter Kit allows the E8408A to
be flush-mounted or recess-mounted up to 8 inches in one-
inch increments. In addition, the rack mount kit includes a
1.125-inch-wide cable route on the mainframe’s right side,
plus stick-on labels for use when the mainframe is mounted
in a horizontal position. To mount the E8408A in Agilent
rack cabinets, order the E8397A Rack Mount Cable Route
Adapter Kit and either the E3663AC Support Rail Kit or
1494-0413 Rack Slide Kit. The 1494-0413 Rack Slide Kit can
be mounted in non-Agilent rack cabinets using 1494-0061
End Brackets.
Accessories and Configurations