Agilent Technologies Agilent G1369B Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt rejestrujący Agilent Technologies Agilent G1369B. Agilent Technologies Agilent G1369B User manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 206
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - Autosampler

Agilent TechnologiesAgilent 1260 Infinity High Performance AutosamplerUser Manual

Strona 2

10 Agilent 1260 Infinity High Performance Autosampler User Manual1 IntroductionFeaturesFeaturesThe 1260 Infinity High Performance Autosampler features

Strona 3 - In This Guide

100 Agilent 1260 Infinity High Performance Autosampler User Manual7 Error InformationModule Error MessagesMetering Home FailedError ID: 4054, 4704The

Strona 4

Agilent 1260 Infinity High Performance Autosampler User Manual 101Error Information7Module Error MessagesMotor TemperatureError ID: 4027, 4040, 4261,

Strona 5 - Contents

102 Agilent 1260 Infinity High Performance Autosampler User Manual7 Error InformationModule Error MessagesInvalid Vial PositionError ID: 4042The vial

Strona 6

Agilent 1260 Infinity High Performance Autosampler User Manual 103Error Information7Module Error MessagesPeristaltic Pump ErrorError ID: 4514The peris

Strona 7

104 Agilent 1260 Infinity High Performance Autosampler User Manual7 Error InformationModule Error MessagesVessel Stuck to NeedleError ID: 4453The vess

Strona 8

105Agilent 1260 Infinity High Performance Autosampler User ManualAgilent Technologies8Test FunctionsIntroduction 106System Pressure Test 107System Pre

Strona 9

106 Agilent 1260 Infinity High Performance Autosampler User Manual8 Test FunctionsIntroductionIntroductionAll tests are described based on the Agilent

Strona 10 - Features

Agilent 1260 Infinity High Performance Autosampler User Manual 107Test Functions8System Pressure TestSystem Pressure TestThe test determines the leak

Strona 11 - Overview of the Module

108 Agilent 1260 Infinity High Performance Autosampler User Manual8 Test FunctionsSystem Pressure Test1 Run the System pressure test with the Agilent

Strona 12 - 1 Introduction

Agilent 1260 Infinity High Performance Autosampler User Manual 109Test Functions8System Pressure TestSystem Pressure Test EvaluationSystem Pressure Te

Strona 13 - Autosampler Principle

Agilent 1260 Infinity High Performance Autosampler User Manual 11Introduction1Overview of the ModuleOverview of the ModuleThe Autosampler transport me

Strona 14 - Injection Sequence

110 Agilent 1260 Infinity High Performance Autosampler User Manual8 Test FunctionsSample Transport Self AlignmentSample Transport Self AlignmentThe sa

Strona 15

Agilent 1260 Infinity High Performance Autosampler User Manual 111Test Functions8Sample Transport Self Alignment1 Run the Transport Alignment with the

Strona 16

112 Agilent 1260 Infinity High Performance Autosampler User Manual8 Test FunctionsMaintenance PositionsMaintenance PositionsSome maintenance procedure

Strona 17

Agilent 1260 Infinity High Performance Autosampler User Manual 113Test Functions8Maintenance PositionsChange NeedleThe position is positioning the nee

Strona 18

114 Agilent 1260 Infinity High Performance Autosampler User Manual8 Test FunctionsMaintenance PositionsArm PositionThe home position of the autosample

Strona 19 - System Overview

Agilent 1260 Infinity High Performance Autosampler User Manual 115Test Functions8Maintenance PositionsChange Metering DeviceWhen removing the metering

Strona 20

116 Agilent 1260 Infinity High Performance Autosampler User Manual8 Test FunctionsInjector StepsInjector StepsEach movement of the sampling sequence c

Strona 21

Agilent 1260 Infinity High Performance Autosampler User Manual 117Test Functions8Injector StepsStep CommandsTabl e 5 Step CommandsStep Action Comments

Strona 22

118 Agilent 1260 Infinity High Performance Autosampler User Manual8 Test FunctionsInjector Steps

Strona 23 - Agilent Technologies

119Agilent 1260 Infinity High Performance Autosampler User ManualAgilent Technologies9MaintenanceIntroduction to Maintenance 120Warnings and Cautions

Strona 24 - Site Requirements

12 Agilent 1260 Infinity High Performance Autosampler User Manual1 IntroductionOverview of the ModuleControl of the vial/plate temperature in the ther

Strona 25 - Power Cords

120 Agilent 1260 Infinity High Performance Autosampler User Manual9 MaintenanceIntroduction to MaintenanceIntroduction to MaintenanceFigure 29 on page

Strona 26 - Condensation

Agilent 1260 Infinity High Performance Autosampler User Manual 121Maintenance9Warnings and CautionsWarnings and CautionsWARNINGToxic, flammable and ha

Strona 27 - Physical Specifications

122 Agilent 1260 Infinity High Performance Autosampler User Manual9 MaintenanceOverview of MaintenanceOverview of MaintenanceThe following pages descr

Strona 28 - Specifications

Agilent 1260 Infinity High Performance Autosampler User Manual 123Maintenance9Cleaning the moduleCleaning the moduleTo keep the module case clean, use

Strona 29

124 Agilent 1260 Infinity High Performance Autosampler User Manual9 MaintenanceRemoving the needle assemblyRemoving the needle assembly When When the

Strona 30

Agilent 1260 Infinity High Performance Autosampler User Manual 125Maintenance9Removing the needle assembly1In the user interface start the maintenance

Strona 31 - Installing the Autosampler

126 Agilent 1260 Infinity High Performance Autosampler User Manual9 MaintenanceRemoving the needle assembly5Attach a 5/16 inch wrench to hold the posi

Strona 32 - Unpacking the Autosampler

Agilent 1260 Infinity High Performance Autosampler User Manual 127Maintenance9Installing the needle assemblyInstalling the needle assembly When When t

Strona 33 - Delivery Checklist

128 Agilent 1260 Infinity High Performance Autosampler User Manual9 MaintenanceInstalling the needle assembly1Push the silicon safety tube delivered w

Strona 34 - 3 Installing the Autosampler

Agilent 1260 Infinity High Performance Autosampler User Manual 129Maintenance9Installing the needle assembly5Close the leak guideNext Steps:6 Check th

Strona 35

Agilent 1260 Infinity High Performance Autosampler User Manual 13Introduction1Autosampler PrincipleAutosampler PrincipleThe movements of the autosampl

Strona 36 - One Stack Configuration

130 Agilent 1260 Infinity High Performance Autosampler User Manual9 MaintenanceExchanging the Needle SeatExchanging the Needle SeatWhen When seat is v

Strona 37

Agilent 1260 Infinity High Performance Autosampler User Manual 131Maintenance9Exchanging the Needle Seat3Disconnect the seat capillary from the Inject

Strona 38 - Two Stack Configuration

132 Agilent 1260 Infinity High Performance Autosampler User Manual9 MaintenanceReplacing the Rotor sealReplacing the Rotor seal When When poor injecti

Strona 39

Agilent 1260 Infinity High Performance Autosampler User Manual 133Maintenance9Replacing the Rotor seal3Unscrew and remove the three stator screws from

Strona 40

134 Agilent 1260 Infinity High Performance Autosampler User Manual9 MaintenanceReplacing the Rotor seal7Install new rotor seal and isolation seal. 8 R

Strona 41

Agilent 1260 Infinity High Performance Autosampler User Manual 135Maintenance9Removing the Metering SealRemoving the Metering Seal When When poor inje

Strona 42

136 Agilent 1260 Infinity High Performance Autosampler User Manual9 MaintenanceRemoving the Metering Seal3Remove the two attached capillaries with a ¼

Strona 43

Agilent 1260 Infinity High Performance Autosampler User Manual 137Maintenance9Removing the Metering Seal7Remove the head body. 8 Carefully remove the

Strona 44

138 Agilent 1260 Infinity High Performance Autosampler User Manual9 MaintenanceInstalling the Metering SealInstalling the Metering Seal When When poor

Strona 45

Agilent 1260 Infinity High Performance Autosampler User Manual 139Maintenance9Installing the Metering Seal3Press the piston into the seal. 4 Reinstall

Strona 46

14 Agilent 1260 Infinity High Performance Autosampler User Manual1 IntroductionAutosampler PrincipleInjection SequenceBefore the start of the injectio

Strona 47 - Using the Module

140 Agilent 1260 Infinity High Performance Autosampler User Manual9 MaintenanceReplacing Peristaltic Pump CartridgeReplacing Peristaltic Pump Cartridg

Strona 48 - Leak and Waste Handling

Agilent 1260 Infinity High Performance Autosampler User Manual 141Maintenance9Replacing Peristaltic Pump Cartridge3Pull the cartridge forward off the

Strona 49 - Preparing the Autosampler

142 Agilent 1260 Infinity High Performance Autosampler User Manual9 MaintenanceReplacing Peristaltic Pump Cartridge7Push the cartridge onto the motor

Strona 50 - 4 Using the Module

Agilent 1260 Infinity High Performance Autosampler User Manual 143Maintenance9Installing the Interface BoardInstalling the Interface Board1 Switch OFF

Strona 51

144 Agilent 1260 Infinity High Performance Autosampler User Manual9 MaintenanceReplacing the Module FirmwareReplacing the Module FirmwareTo upgrade/do

Strona 52

145Agilent 1260 Infinity High Performance Autosampler User ManualAgilent Technologies10Parts for MaintenanceOverview of Maintenance Parts 146Vial Tray

Strona 53 - '

146 Agilent 1260 Infinity High Performance Autosampler User Manual10 Parts for MaintenanceOverview of Maintenance PartsOverview of Maintenance Parts I

Strona 54

Agilent 1260 Infinity High Performance Autosampler User Manual 147Parts for Maintenance10Vial TraysVial Trays &'()*+,Item p/n Description1 G2

Strona 55 - Control Settings

148 Agilent 1260 Infinity High Performance Autosampler User Manual10 Parts for MaintenanceRecommended Plates and Closing MatsRecommended Plates and Cl

Strona 56 - Method Parameter Settings

Agilent 1260 Infinity High Performance Autosampler User Manual 149Parts for Maintenance10Recommended Vial PlatesRecommended Vial Platesp/n Description

Strona 57

Agilent 1260 Infinity High Performance Autosampler User Manual 15Introduction1Autosampler PrincipleWhen the sample sequence begins, the valve unit swi

Strona 58

150 Agilent 1260 Infinity High Performance Autosampler User Manual10 Parts for MaintenanceKitsKitsAccessory Kit Injection Ugrade KitUpgrade Kit for hi

Strona 59

Agilent 1260 Infinity High Performance Autosampler User Manual 151Parts for Maintenance10Analytical Head AssemblyAnalytical Head Assembly Figure 30 An

Strona 60 - Module Configuration

152 Agilent 1260 Infinity High Performance Autosampler User Manual10 Parts for MaintenanceInjection Valve AssemblyInjection Valve Assembly &

Strona 61 - (G4208A)

Agilent 1260 Infinity High Performance Autosampler User Manual 153Parts for Maintenance10Cover PartsCover Parts&Item p/n Description1 5067-4662 Ca

Strona 62

154 Agilent 1260 Infinity High Performance Autosampler User Manual10 Parts for MaintenanceLeak System PartsLeak System Parts Figure 31 Leak system par

Strona 63

155Agilent 1260 Infinity High Performance Autosampler User ManualAgilent Technologies11Identifying CablesCable Overview 156Analog Cables 158Remote Cab

Strona 64

156 Agilent 1260 Infinity High Performance Autosampler User Manual11 Identifying CablesCable OverviewCable OverviewAnalog cablesRemote cablesBCD cable

Strona 65 - Optimizing Performance

Agilent 1260 Infinity High Performance Autosampler User Manual 157Identifying Cables11Cable OverviewCAN cablesLAN cablesRS-232 cablesp/n Description51

Strona 66 - Delay Volume

158 Agilent 1260 Infinity High Performance Autosampler User Manual11 Identifying CablesAnalog CablesAnalog CablesOne end of these cables provides a BN

Strona 67

Agilent 1260 Infinity High Performance Autosampler User Manual 159Identifying Cables11Analog CablesAgilent Module to General Purposep/n 01046-60105 Pi

Strona 68 - 5 Optimizing Performance

16 Agilent 1260 Infinity High Performance Autosampler User Manual1 IntroductionAutosampler PrincipleThe standard injection starts with draw sample fro

Strona 69

160 Agilent 1260 Infinity High Performance Autosampler User Manual11 Identifying CablesRemote CablesRemote CablesOne end of these cables provides a Ag

Strona 70

Agilent 1260 Infinity High Performance Autosampler User Manual 161Identifying Cables11Remote CablesAgilent Module to 3396 Series III / 3395B Integrato

Strona 71

162 Agilent 1260 Infinity High Performance Autosampler User Manual11 Identifying CablesRemote CablesAgilent Module to General Purposep/n 01046-60201 W

Strona 72

Agilent 1260 Infinity High Performance Autosampler User Manual 163Identifying Cables11BCD CablesBCD CablesOne end of these cables provides a 15- pin B

Strona 73

164 Agilent 1260 Infinity High Performance Autosampler User Manual11 Identifying CablesBCD CablesAgilent Module to 3396 Integratorsp/n 03396-60560 Pin

Strona 74

Agilent 1260 Infinity High Performance Autosampler User Manual 165Identifying Cables11CAN/LAN CablesCAN/LAN CablesBoth ends of this cable provide a mo

Strona 75

166 Agilent 1260 Infinity High Performance Autosampler User Manual11 Identifying CablesExternal Contact CableExternal Contact CableOne end of this cab

Strona 76

Agilent 1260 Infinity High Performance Autosampler User Manual 167Identifying Cables11Agilent Module to PCAgilent Module to PCp/n DescriptionG1530-606

Strona 77

168 Agilent 1260 Infinity High Performance Autosampler User Manual11 Identifying CablesAgilent 1200 Module to PrinterAgilent 1200 Module to Printerp/n

Strona 78

169Agilent 1260 Infinity High Performance Autosampler User ManualAgilent Technologies12Hardware InformationFirmware Description 170Boot-up and Initial

Strona 79

Agilent 1260 Infinity High Performance Autosampler User Manual 17Introduction1Autosampler PrincipleFlush the Needle Before injection and to reduce the

Strona 80 - Error Messages

170 Agilent 1260 Infinity High Performance Autosampler User Manual12 Hardware InformationFirmware DescriptionFirmware DescriptionThe firmware of the i

Strona 81

Agilent 1260 Infinity High Performance Autosampler User Manual 171Hardware Information12Firmware DescriptionFirmware UpdatesFirmware updates can be do

Strona 82 - Module Status Indicator

172 Agilent 1260 Infinity High Performance Autosampler User Manual12 Hardware InformationFirmware DescriptionThe firmware update tools, firmware and d

Strona 83 - User Interfaces

Agilent 1260 Infinity High Performance Autosampler User Manual 173Hardware Information12Boot-up and Initialization ProcessBoot-up and Initialization P

Strona 84 - Agilent Lab Advisor Software

174 Agilent 1260 Infinity High Performance Autosampler User Manual12 Hardware InformationElectrical ConnectionsElectrical Connections• The CAN bus is

Strona 85 - Error Information

Agilent 1260 Infinity High Performance Autosampler User Manual 175Hardware Information12Electrical ConnectionsRear view of the moduleFigure 33 Rear vi

Strona 86 - 7 Error Information

176 Agilent 1260 Infinity High Performance Autosampler User Manual12 Hardware InformationInterfacesInterfacesThe Agilent 1200 Infinity Series modules

Strona 87 - What are Error Messages

Agilent 1260 Infinity High Performance Autosampler User Manual 177Hardware Information12InterfacesDetectorsG1314B VWD VLG1314C VWD VL+2 Yes N o Ye s 1

Strona 88 - General Error Messages

178 Agilent 1260 Infinity High Performance Autosampler User Manual12 Hardware InformationInterfaces• CAN connectors as interface to other modules• LAN

Strona 89 - Lost CAN Partner

Agilent 1260 Infinity High Performance Autosampler User Manual 179Hardware Information12Interfaces Overview Interfaces CANThe CAN is inter- module com

Strona 90 - Leak Sensor Open

18 Agilent 1260 Infinity High Performance Autosampler User Manual1 IntroductionAutosampler PrincipleInject-and-Run The final step is the inject- and-

Strona 91 - Compensation Sensor Open

180 Agilent 1260 Infinity High Performance Autosampler User Manual12 Hardware InformationInterfacesThe RS- 232C is designed as DCE (data communication

Strona 92 - Fan Failed

Agilent 1260 Infinity High Performance Autosampler User Manual 181Hardware Information12InterfacesAPG RemoteThe APG Remote connector may be used in co

Strona 93 - Module Error Messages

182 Agilent 1260 Infinity High Performance Autosampler User Manual12 Hardware InformationInterfacesSpecial InterfacesThe CAN DC- out provides 24 VDC p

Strona 94 - Side Door Error

Agilent 1260 Infinity High Performance Autosampler User Manual 183Hardware Information12Setting the 8-bit Configuration SwitchSetting the 8-bit Config

Strona 95 - Valve to Mainpass Failed

184 Agilent 1260 Infinity High Performance Autosampler User Manual12 Hardware InformationSetting the 8-bit Configuration SwitchCommunication Settings

Strona 96 - Needle Lock Failed

Agilent 1260 Infinity High Performance Autosampler User Manual 185Hardware Information12Setting the 8-bit Configuration SwitchUse the following tables

Strona 97 - Needle Carrier Failed

186 Agilent 1260 Infinity High Performance Autosampler User Manual12 Hardware InformationSetting the 8-bit Configuration SwitchSpecial SettingsThe spe

Strona 98

Agilent 1260 Infinity High Performance Autosampler User Manual 187Hardware Information12Instrument LayoutInstrument LayoutThe industrial design of the

Strona 99 - Initialization Failed

188 Agilent 1260 Infinity High Performance Autosampler User Manual12 Hardware InformationEarly Maintenance FeedbackEarly Maintenance FeedbackMaintenan

Strona 100 - Metering Home Failed

189Agilent 1260 Infinity High Performance Autosampler User ManualAgilent Technologies13LAN ConfigurationSetting up the module in a LAN environment 190

Strona 101 - Motor Temperature

Agilent 1260 Infinity High Performance Autosampler User Manual 19Introduction1System OverviewSystem OverviewLeak and Waste HandlingThe 1200 Infinity S

Strona 102 - Invalid Vial Position

190 Agilent 1260 Infinity High Performance Autosampler User Manual13 LAN ConfigurationSetting up the module in a LAN environmentSetting up the module

Strona 103 - Vessel or Wash Vessel Error

Agilent 1260 Infinity High Performance Autosampler User Manual 191LAN Configuration13Connecting the module via LANConnecting the module via LANIf the

Strona 104 - Rear Blind Seat Missing

192 Agilent 1260 Infinity High Performance Autosampler User Manual13 LAN ConfigurationConnecting the module via LAN

Strona 105 - Test Functions

193Agilent 1260 Infinity High Performance Autosampler User ManualAgilent Technologies14AppendixGeneral Safety Information 194Lithium Batteries Informa

Strona 106 - Introduction

194 Agilent 1260 Infinity High Performance Autosampler User Manual14 AppendixGeneral Safety InformationGeneral Safety InformationGeneral Safety Inform

Strona 107 - System Pressure Test

Agilent 1260 Infinity High Performance Autosampler User Manual 195Appendix14General Safety InformationOperationBefore applying power, comply with the

Strona 108 - 8 Test Functions

196 Agilent 1260 Infinity High Performance Autosampler User Manual14 AppendixGeneral Safety InformationSafety SymbolsTabl e 18 Safety SymbolsSymbol De

Strona 109

Agilent 1260 Infinity High Performance Autosampler User Manual 197Appendix14Lithium Batteries InformationLithium Batteries InformationWARNINGLithium b

Strona 110

198 Agilent 1260 Infinity High Performance Autosampler User Manual14 AppendixThe Waste Electrical and Electronic Equipment (WEEE) Directive (2002/96/E

Strona 111

Agilent 1260 Infinity High Performance Autosampler User Manual 199Appendix14Radio InterferenceRadio InterferenceNever use cables other than the ones s

Strona 112 - Maintenance Positions

Agilent 1260 Infinity High Performance Autosampler User ManualNotices© Agilent Technologies, Inc. 2010-2013, 2014No part of this manual may be reprodu

Strona 113 - Change Loop Capillary

20 Agilent 1260 Infinity High Performance Autosampler User Manual1 IntroductionSystem OverviewFigure 6 Leak and waste handling concept (overview - typ

Strona 114 - Change Needle Carrier

200 Agilent 1260 Infinity High Performance Autosampler User Manual14 AppendixSound EmissionSound EmissionManufacturer’s DeclarationThis statement is p

Strona 115 - Change Metering Device

Agilent 1260 Infinity High Performance Autosampler User Manual 201Appendix14Use of SolventsUse of Solvents Observe the following recommendations on th

Strona 116 - Injector Steps

202 Agilent 1260 Infinity High Performance Autosampler User Manual14 AppendixAgilent Technologies on InternetAgilent Technologies on InternetFor the l

Strona 117 - Step Commands

Agilent 1260 Infinity High Performance Autosampler User Manual 203IndexIndex88-bit configuration switchwithout On-Board LAN 183Aaccessory kit 34Agilen

Strona 118

204 Agilent 1260 Infinity High Performance Autosampler User ManualIndexexternal contactcable 166extra-column volume 66Ffan failed 92firmwaredescriptio

Strona 119 - Maintenance

Agilent 1260 Infinity High Performance Autosampler User Manual 205IndexSsafety class I 194safety informationlithium batteries 197safetygeneral informa

Strona 120 - Introduction to Maintenance

© Agilent Technologies 2010-2013, 2014Printed in Germany 02/2014*G1367-90014**G1367-90014*G1367-90014Rev. Bwww.agilent.comAgilent TechnologiesIn This

Strona 121 - Warnings and Cautions

Agilent 1260 Infinity High Performance Autosampler User Manual 21Introduction1System OverviewThe solvent cabinet (1) is designed to store a maximum vo

Strona 122 - Overview of Maintenance

22 Agilent 1260 Infinity High Performance Autosampler User Manual1 IntroductionSystem Overview

Strona 123 - Cleaning the module

23Agilent 1260 Infinity High Performance Autosampler User ManualAgilent Technologies2Site Requirements and SpecificationsSite Requirements 24Physical

Strona 124 - Removing the needle assembly

24 Agilent 1260 Infinity High Performance Autosampler User Manual2 Site Requirements and SpecificationsSite RequirementsSite RequirementsA suitable en

Strona 125

Agilent 1260 Infinity High Performance Autosampler User Manual 25Site Requirements and Specifications2Site RequirementsPower CordsDifferent power cord

Strona 126 - 9 Maintenance

26 Agilent 1260 Infinity High Performance Autosampler User Manual2 Site Requirements and SpecificationsSite RequirementsBench SpaceThe module dimensio

Strona 127

Agilent 1260 Infinity High Performance Autosampler User Manual 27Site Requirements and Specifications2Physical SpecificationsPhysical SpecificationsTa

Strona 128

28 Agilent 1260 Infinity High Performance Autosampler User Manual2 Site Requirements and SpecificationsSpecificationsSpecificationsTabl e 2 Performanc

Strona 129

Agilent 1260 Infinity High Performance Autosampler User Manual 29Site Requirements and Specifications2SpecificationsLocal Control Agilent Instant Pilo

Strona 130 - Exchanging the Needle Seat

Agilent 1260 Infinity High Performance Autosampler User Manual 3In This GuideIn This GuideThis manual covers the Agilent 1260 Infinity High Performanc

Strona 131

30 Agilent 1260 Infinity High Performance Autosampler User Manual2 Site Requirements and SpecificationsSpecifications

Strona 132 - Replacing the Rotor seal

31Agilent 1260 Infinity High Performance Autosampler User ManualAgilent Technologies3Installing the AutosamplerUnpacking the Autosampler 32Damaged Pac

Strona 133

32 Agilent 1260 Infinity High Performance Autosampler User Manual3 Installing the AutosamplerUnpacking the AutosamplerUnpacking the AutosamplerDamaged

Strona 134

Agilent 1260 Infinity High Performance Autosampler User Manual 33Installing the Autosampler3Unpacking the AutosamplerDelivery Checklist Ensure all par

Strona 135 - Removing the Metering Seal

34 Agilent 1260 Infinity High Performance Autosampler User Manual3 Installing the AutosamplerUnpacking the AutosamplerAutosampler Accessory Kit Conten

Strona 136

Agilent 1260 Infinity High Performance Autosampler User Manual 35Installing the Autosampler3Optimizing the Stack ConfigurationOptimizing the Stack Con

Strona 137 - >chZgiidda

36 Agilent 1260 Infinity High Performance Autosampler User Manual3 Installing the AutosamplerOptimizing the Stack ConfigurationOne Stack Configuration

Strona 138

Agilent 1260 Infinity High Performance Autosampler User Manual 37Installing the Autosampler3Optimizing the Stack ConfigurationFigure 8 Recommended Sta

Strona 139

38 Agilent 1260 Infinity High Performance Autosampler User Manual3 Installing the AutosamplerOptimizing the Stack ConfigurationTwo Stack Configuration

Strona 140

Agilent 1260 Infinity High Performance Autosampler User Manual 39Installing the Autosampler3Optimizing the Stack ConfigurationFigure 10 Recommended Tw

Strona 141

4 Agilent 1260 Infinity High Performance Autosampler User ManualIn This Guide8Test FunctionsThis chapter describes the tests for the module.9 Maintena

Strona 142

40 Agilent 1260 Infinity High Performance Autosampler User Manual3 Installing the AutosamplerInstallation Information on Leak and Waste HandlingInstal

Strona 143 - 1 Interface board

Agilent 1260 Infinity High Performance Autosampler User Manual 41Installing the Autosampler3Installation Information on Leak and Waste HandlingFigure

Strona 144 - Replacing the Module Firmware

42 Agilent 1260 Infinity High Performance Autosampler User Manual3 Installing the AutosamplerInstallation Information on Leak and Waste Handling1 Stac

Strona 145 - Parts for Maintenance

Agilent 1260 Infinity High Performance Autosampler User Manual 43Installing the Autosampler3Installation Information on Leak and Waste HandlingFigure

Strona 146 - 10 Parts for Maintenance

44 Agilent 1260 Infinity High Performance Autosampler User Manual3 Installing the AutosamplerInstalling the AutosamplerInstalling the Autosampler1 Pla

Strona 147 - Vial Trays

Agilent 1260 Infinity High Performance Autosampler User Manual 45Installing the Autosampler3Installing the Autosampler3 Connect the power cable to the

Strona 148

46 Agilent 1260 Infinity High Performance Autosampler User Manual3 Installing the AutosamplerFlow Connections to the AutosamplerFlow Connections to th

Strona 149 - Recommended Vial Plates

47Agilent 1260 Infinity High Performance Autosampler User ManualAgilent Technologies4Using the ModuleLeak and Waste Handling 48Preparing the Autosampl

Strona 150 - Injection Ugrade Kit

48 Agilent 1260 Infinity High Performance Autosampler User Manual4 Using the ModuleLeak and Waste HandlingLeak and Waste HandlingFor details on correc

Strona 151 - Analytical Head Assembly

Agilent 1260 Infinity High Performance Autosampler User Manual 49Using the Module4Preparing the AutosamplerPreparing the AutosamplerFor best performan

Strona 152 - Injection Valve Assembly

Agilent 1260 Infinity High Performance Autosampler User Manual 5ContentsContents1 Introduction 9Features 10Overview of the Module 11Autosampler Princi

Strona 153 - Cover Parts

50 Agilent 1260 Infinity High Performance Autosampler User Manual4 Using the ModulePreparing the Autosampler• Priming and Purging the System - When t

Strona 154 - Leak System Parts

Agilent 1260 Infinity High Performance Autosampler User Manual 51Using the Module4Setting up the Autosampler with Agilent ChemStationSetting up the Au

Strona 155 - Identifying Cables

52 Agilent 1260 Infinity High Performance Autosampler User Manual4 Using the ModuleSetting up the Autosampler with Agilent ChemStationFigure 14 ChemSt

Strona 156 - Cable Overview

Agilent 1260 Infinity High Performance Autosampler User Manual 53Using the Module4Setting up the Autosampler with Agilent ChemStationThe Autosampler U

Strona 157

54 Agilent 1260 Infinity High Performance Autosampler User Manual4 Using the ModuleSetting up the Autosampler with Agilent ChemStationModule Status sh

Strona 158 - Analog Cables

Agilent 1260 Infinity High Performance Autosampler User Manual 55Using the Module4Setting up the Autosampler with Agilent ChemStationControl SettingsT

Strona 159

56 Agilent 1260 Infinity High Performance Autosampler User Manual4 Using the ModuleSetting up the Autosampler with Agilent ChemStationMethod Parameter

Strona 160 - Remote Cables

Agilent 1260 Infinity High Performance Autosampler User Manual 57Using the Module4Setting up the Autosampler with Agilent ChemStationInjection ModeThe

Strona 161

58 Agilent 1260 Infinity High Performance Autosampler User Manual4 Using the ModuleSetting up the Autosampler with Agilent ChemStationInjection Cleani

Strona 162 - 11 Identifying Cables

Agilent 1260 Infinity High Performance Autosampler User Manual 59Using the Module4Setting up the Autosampler with Agilent ChemStationInjection Program

Strona 163 - BCD Cables

6 Agilent 1260 Infinity High Performance Autosampler User ManualContents6 Troubleshooting and Diagnostics 79Overview of the Module’s Indicators and Te

Strona 164

60 Agilent 1260 Infinity High Performance Autosampler User Manual4 Using the ModuleSetting up the Autosampler with Agilent ChemStationModule Configura

Strona 165 - CAN/LAN Cables

Agilent 1260 Infinity High Performance Autosampler User Manual 61Using the Module4Main Screens of the Autosampler with Agilent Instant Pilot (G4208A)M

Strona 166 - External Contact Cable

62 Agilent 1260 Infinity High Performance Autosampler User Manual4 Using the ModuleMain Screens of the Autosampler with Agilent Instant Pilot (G4208A)

Strona 167 - Agilent Module to PC

Agilent 1260 Infinity High Performance Autosampler User Manual 63Using the Module4Main Screens of the Autosampler with Agilent Instant Pilot (G4208A)T

Strona 168

64 Agilent 1260 Infinity High Performance Autosampler User Manual4 Using the ModuleMain Screens of the Autosampler with Agilent Instant Pilot (G4208A)

Strona 169 - Hardware Information

65Agilent 1260 Infinity High Performance Autosampler User ManualAgilent Technologies5Optimizing PerformanceDelay Volume and Extra-Column Volume 66Dela

Strona 170 - Firmware Description

66 Agilent 1260 Infinity High Performance Autosampler User Manual5 Optimizing PerformanceDelay Volume and Extra-Column VolumeDelay Volume and Extra-Co

Strona 171 - GZh^YZci;LJeYViZ

Agilent 1260 Infinity High Performance Autosampler User Manual 67Optimizing Performance5How to Configure the Optimum Delay VolumeHow to Configure the

Strona 172 - 12 Hardware Information

68 Agilent 1260 Infinity High Performance Autosampler User Manual5 Optimizing PerformanceHow to Configure the Optimum Delay VolumeFigure 16 Schematic

Strona 173 - Obstruction of transport unit

Agilent 1260 Infinity High Performance Autosampler User Manual 69Optimizing Performance5How to Configure the Optimum Delay VolumeThe ADVR function is

Strona 174 - Electrical Connections

Agilent 1260 Infinity High Performance Autosampler User Manual 7Contents10 Parts for Maintenance 145Overview of Maintenance Parts 146Vial Trays 147Rec

Strona 175 - Rear view of the module

70 Agilent 1260 Infinity High Performance Autosampler User Manual5 Optimizing PerformanceHow to Achieve Higher Injection VolumesHow to Achieve Higher

Strona 176 - Interfaces

Agilent 1260 Infinity High Performance Autosampler User Manual 71Optimizing Performance5How to Achieve Higher Injection Volumesbut it is very dependen

Strona 177

72 Agilent 1260 Infinity High Performance Autosampler User Manual5 Optimizing PerformanceHow to Achieve High ThroughputHow to Achieve High ThroughputT

Strona 178

Agilent 1260 Infinity High Performance Autosampler User Manual 73Optimizing Performance5How to Achieve Higher ResolutionHow to Achieve Higher Resoluti

Strona 179 - Overview Interfaces

74 Agilent 1260 Infinity High Performance Autosampler User Manual5 Optimizing PerformanceHow to Achieve Higher ResolutionThe resolution equation shows

Strona 180 - BVaZ ;ZbVaZ ;ZbVaZ BVaZ

Agilent 1260 Infinity High Performance Autosampler User Manual 75Optimizing Performance5How to Achieve Higher ResolutionIn isocratic separations, incr

Strona 181 - APG Remote

76 Agilent 1260 Infinity High Performance Autosampler User Manual5 Optimizing PerformanceHow to Achieve Higher SensitivityHow to Achieve Higher Sensit

Strona 182 - Special Interfaces

Agilent 1260 Infinity High Performance Autosampler User Manual 77Optimizing Performance5How to Achieve Lowest Carry OverHow to Achieve Lowest Carry Ov

Strona 183

78 Agilent 1260 Infinity High Performance Autosampler User Manual5 Optimizing PerformanceHow to Achieve Lowest Carry OverThe flush port is located abo

Strona 184

79Agilent 1260 Infinity High Performance Autosampler User ManualAgilent Technologies6Troubleshooting and DiagnosticsOverview of the Module’s Indicator

Strona 185

8 Agilent 1260 Infinity High Performance Autosampler User ManualContents14 Appendix 193General Safety Information 194Lithium Batteries Information 197

Strona 186 - Special Settings

80 Agilent 1260 Infinity High Performance Autosampler User Manual6 Troubleshooting and DiagnosticsOverview of the Module’s Indicators and Test Functio

Strona 187 - Instrument Layout

Agilent 1260 Infinity High Performance Autosampler User Manual 81Troubleshooting and Diagnostics6Status IndicatorsStatus IndicatorsTwo status indicato

Strona 188 - Early Maintenance Feedback

82 Agilent 1260 Infinity High Performance Autosampler User Manual6 Troubleshooting and DiagnosticsStatus IndicatorsModule Status IndicatorThe module s

Strona 189 - LAN Configuration

Agilent 1260 Infinity High Performance Autosampler User Manual 83Troubleshooting and Diagnostics6User InterfacesUser Interfaces• Depending on the user

Strona 190 - 13 LAN Configuration

84 Agilent 1260 Infinity High Performance Autosampler User Manual6 Troubleshooting and DiagnosticsAgilent Lab Advisor SoftwareAgilent Lab Advisor Soft

Strona 191 - Connecting the module via LAN

85Agilent 1260 Infinity High Performance Autosampler User ManualAgilent Technologies7Error InformationWhat are Error Messages 87General Error Messages

Strona 192

86 Agilent 1260 Infinity High Performance Autosampler User Manual7 Error InformationAgilent Lab Advisor SoftwareVessel or Wash Vessel Error 103Vessel

Strona 193 - Appendix

Agilent 1260 Infinity High Performance Autosampler User Manual 87Error Information7What are Error MessagesWhat are Error MessagesError messages are di

Strona 194 - General Safety Information

88 Agilent 1260 Infinity High Performance Autosampler User Manual7 Error InformationGeneral Error MessagesGeneral Error MessagesGeneral error messages

Strona 195 - Operation

Agilent 1260 Infinity High Performance Autosampler User Manual 89Error Information7General Error Messages Remote Timeout Error ID: 0070A not- ready co

Strona 196 - Safety Symbols

9Agilent 1260 Infinity High Performance Autosampler User ManualAgilent Technologies1IntroductionFeatures 10Overview of the Module 11Autosampler Princi

Strona 197 - Lithium Batteries Information

90 Agilent 1260 Infinity High Performance Autosampler User Manual7 Error InformationGeneral Error MessagesLeakError ID: 0064A leak was detected in the

Strona 198 - (2002/96/EC)

Agilent 1260 Infinity High Performance Autosampler User Manual 91Error Information7General Error MessagesLeak Sensor ShortError ID: 0082The leak senso

Strona 199 - Radio Interference

92 Agilent 1260 Infinity High Performance Autosampler User Manual7 Error InformationGeneral Error MessagesCompensation Sensor ShortError ID: 0080The a

Strona 200 - Sound Emission

Agilent 1260 Infinity High Performance Autosampler User Manual 93Error Information7Module Error MessagesModule Error MessagesThese errors are autosamp

Strona 201 - Use of Solvents

94 Agilent 1260 Infinity High Performance Autosampler User Manual7 Error InformationModule Error MessagesSide Door ErrorError ID: 4355, 4459The side d

Strona 202 - 14 Appendix

Agilent 1260 Infinity High Performance Autosampler User Manual 95Error Information7Module Error MessagesValve to Bypass FailedError ID: 4014, 4701The

Strona 203

96 Agilent 1260 Infinity High Performance Autosampler User Manual7 Error InformationModule Error MessagesNeedle Lock FailedError ID: 4702, 4703The loc

Strona 204

Agilent 1260 Infinity High Performance Autosampler User Manual 97Error Information7Module Error MessagesNeedle to Needle Seat PositionError ID: 4510,

Strona 205

98 Agilent 1260 Infinity High Performance Autosampler User Manual7 Error InformationModule Error MessagesMissing Vial or Missing Wash VialError ID: 40

Strona 206 - *G1367-90014*

Agilent 1260 Infinity High Performance Autosampler User Manual 99Error Information7Module Error MessagesInitialization FailedError ID: 4020The autosam

Komentarze do niniejszej Instrukcji

Brak uwag