Agilent Technologies Switch/Measure Instrukcja Użytkownika Strona 31

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 36
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 30
31
Reference interference level
Purpose of measurementswhat it proves
Reference interference level tests the receiver’s ability to demodulate and decode
a GSM signal in the presence of an interfering signal. This ETSI specification
covers both co-channel and adjacent channel interference. For co-channel testing,
two GSM modulated signals are applied to the receiver. The wanted signal level is
9 dB above the interfering signal level.
For adjacent channel testing, two GSM modulated signals are applied to the
receiver. This time the interfering signal will be 200 kHz offset and 9 dB above
the wanted signal. The adjacent channel test is repeated at 400 kHz offset and
41 dB above the wanted signal.
Theory in pictures
Graphical view of limits and specifications
Channel Type Error Parameter Limit Value %
RACH FER 16
TCH/F9.6 BER 0.8
TCH/FS FER 6α
Class Ib RBER 0.4/α
Class II RBER 8
Co-channel rejection
Wanted signal –84 dBm
Interfering signal –95 dBm
Adjacent channel rejection
Wanted signal –84 dBm
Interfering signal –75 dBm + 200 kHz
Przeglądanie stron 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36

Komentarze do niniejszej Instrukcji

Brak uwag