Agilent Technologies
Agilent U1211A, U1212A,
and U1213A Clamp Meter
Quick Start Guide
The following items are included with your clamp meter:
Standard test leads with 4 mm probes
Soft carrying case
Quick Start Guide
Certificate of Calibration
If any item is missing or damaged, contact your nearest Agilent Sales
Office.
For more detailed information, please refer to the Agilent U1211A, U1212A,
and U1213A Clamp Meter User’s and Service Guide on Agilent Website:
www.agilent.com/find/handheld-tools
U1211A U1212A U1213A
Przeglądanie stron 0
1 2 3 4 5 6 ... 16 17

Podsumowanie treści

Strona 1 - Quick Start Guide

Agilent TechnologiesAgilent U1211A, U1212A, and U1213A Clamp MeterQuick Start GuideThe following items are included with your clamp meter:✔Standard te

Strona 2 - Knowing Your Clamp Meter

Quick Start GuidePerforming Diode MeasurementConnectProbe and read1 Set the rotary switch to .2 Connect the red and black test leads to input termina

Strona 3 - Functions and Features

Quick Start GuidePerforming Capacitance MeasurementProbeand readPressConnectCAUTIONCAUTIONDischarge the capacitors before performing the measurements

Strona 4 - Annunciator Display

Quick Start GuidePerforming Temperature MeasurementConnectPress twiceProbe and readFor U1212A and U1213A only1 Set the rotary switch to Ω.2 Press Shif

Strona 5 - Input Terminals

Quick Start GuideReplacing the Battery1 Set the rotary switch to OFF.2 Disconnect test leads from the input terminal.3 Loosen the screw on the battery

Strona 6

Quick Start GuideRegulatory MarkingsThe CE mark is a registered trademark of the European Community. This CE mark shows that the product complies wit

Strona 7

Quick Start Guide

Strona 8

Safety Notices Safety SymbolsCAUTIONCAUTIONA CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that

Strona 9 - Continuity Test

Printed in MalaysiaU1211-90011Third Edition, June 14, 2012© Agilent Technologies, Inc., 2009–2012Agilent Technologies

Strona 10 - Performing Diode Measurement

Quick Start GuideKnowing Your Clamp MeterClamp jawHandleHand guardAnnunciatorJaw markingsRotary switchFunction buttonsHold/ Max Min buttonRed input te

Strona 11 - CAUTIONCAUTION

Quick Start GuideFunctions and FeaturesRotary switchFunction buttons[1] Duty cycle % function is only available for U1213A.Measurements and power off

Strona 12

Quick Start GuideAnnunciator DisplayNo. Annunciator Status1 AUTO Indicates auto ranging2 Zeroing mode3 DH Data hold4 MAX AVG MIN Dynamic recording mod

Strona 13 - Replacing the Battery

Quick Start GuideInput Terminals[1] DC current measurement is only available for U1212A and U1213A.[2] Temperature function is only available for U121

Strona 14 - Regulatory Markings

Quick Start GuidePerforming Current MeasurementWARNINGEnsure the test leads are disconnected from the input terminals when measuring current with the

Strona 15

Quick Start GuideCAUTIONCAUTIONEnsure that the clamp meter measures only one conductor at a time. Measuring multiple conductors may cause inaccuracy

Strona 16 - Safety Notices Safety Symbols

Quick Start GuidePerforming Voltage MeasurementPressConnect1 Set the rotary switch to ~V.2 Connect the red and black test leads to input terminals V (

Strona 17 - U1211-90011

Quick Start GuidePerforming Resistance Measurement and Continuity TestConnectProbeand readAudible continuity1 Set the rotary switch to Ω.2 Connect the