Agilent InfiniiVision 5000
Series Portable Oscilloscopes
Data Sheet
The Next Generation of Portable Oscilloscopes
Przeglądanie stron 0
1 2 3 4 5 6 ... 22 23

Podsumowanie treści

Strona 1 - Series Portable Oscilloscopes

Agilent InfiniiVision 5000 Series Portable OscilloscopesData SheetThe Next Generation of Portable Oscilloscopes

Strona 2

ProbingTogetthemostoutofyourscope,youneed the right probes and accessories foryourapplication.That’swhyAgilentTechnologies offers a com

Strona 3 - Don’t take our word for it

Selection guide (continued)Current probes Description 1147B 50-MHz115Acurrentprobe,AC/DC1146A 100-kHzcurrentprobe,AC/DCN2780A 2-MHz/500

Strona 4 - Why does deep memory matter?

ConnectivityOurcustomerstellusthatoscilloscopeconnectivityisanincreasinglyimportantfeatureoftheirtestinstruments.That’swhythe5000S

Strona 5 - Time Base

Performance characteristicsAcquisitionSamplerate DSO501xA/503xA:2GSa/aeachchannel   DSO505xA:4GSa/shalfchannel1, 2 GSa/s each channelEqui

Strona 6 - Software options

Performance characteristics (continued)Vertical system (continued)Range1 2mV/divto5V/div(1MΩor50Ω)Maximuminput Maximuminputvoltagefor

Strona 7 - Software options (continued)

Performance characteristics (continued)HorizontalRange DSO501xA:5nsec/divto50sec/div   DSO503xA:2nsec/divto50sec/div   DSO505xA:1nse

Strona 8 - Other nice features

Performance characteristics (continued)Trigger system (continued)Selections Edge,pulsewidth,pattern,TV,duration  Edge Triggeronarising,

Strona 9

Performance characteristics (continued)Channel triggeringRange(internal) ±6divfromcenterscreenSensitivity1 <10mV/div:greaterof1divo

Strona 10 - Selection guide

Performance characteristics (continued)Measurement featuresAutomaticmeasurements Measurementsarecontinuouslyupdated.Cursorstracklastselected

Strona 11 - Probing (continued)

Performance characteristics (continued)General characteristicsPhysicalsize 35.4cmwidex18.8cmhighx17.4cmdeep(withouthandle)   38.5cm

Strona 12 - Connectivity

2• 100, 300, and 500 MHz bandwidths• 2 or 4 channels• MegaZoom III memory and display technology• 8Mptsacquisitionmemory• Upto100,000wavef

Strona 13 - Performance characteristics

Ordering informationAvailable modelsProduct number Description DSO5012A 100MHz,2-channelportableoscilloscopeDSO5014A 100MHz,4-channelportab

Strona 14 - (continued)

OptionsProduct number Description SEC Secureenvironmentmode–ProvidescompliancewithNationalIndustrialSecurity   ProgramOperatingManua

Strona 15

22Agilent Technologies OscilloscopesMultiple form factors from 20 MHz to > 90 GHz | Industry leading specs | Powerful applications

Strona 16

MicrosoftisaU.S.registeredtrademarkofMicrosoft Corporation.www.lxistandard.orgLANeXtensionsforInstrumentsputsthepowerofEthernetandthe

Strona 17

3If you haven’t purchased an Agilent oscilloscope lately, why should you consider one now?Leading-edge technology for all scope usersThe InfiniiVision

Strona 18

4Why does deep memory matter?See more timeSeeing more time is the most easily understooduseofdeepmemory.Themoresamplesyouacquire,themoreti

Strona 19

5Why does a fast update rate matter?Ifthehumaneyehastroublediscerningabove30-50framespersecond, is there really a difference between 3,600

Strona 20 - Ordering information

6Software optionsFigure 7. Real-time totalize functions provide CAN bus efficiency and quality measurement statisticsCAN/LIN triggering and decode (N5

Strona 21

7RS-232/UART serial decode and trigger (N5457A or Option 232 on new scope purchases)Theapplicationletsyoueasilyviewtheinformationsentovera

Strona 22

8Other nice featuresHigh resolution mode Offersupto12bitsofverticalresolutioninreal-time,single-shotmode. This is accomplished by serially

Strona 23 - ISO 9001:2008

9Figure 15. View and analyze previously acquired scope data on a PC-based offline toolOther nice features (continued)Peak detect 250 ps peak detect on