Agilent 11970 Series Harmonic MixersUser’s GuideThis manual provides documentation for the following harmonic mixers:K, A, Q, U, V, and W Models

Strona 2

10 General InformationIntroductionIntroductionThe Agilent Models 11970K, 11970A, 11970Q, 11970U, 11970V and 11970W are general-purpose harmonic mi

Strona 3 - In This Guide…

11General InformationIntroduction11970 Series Harmonic MixersFigure 1-1 OptionsOption 009, shown in Figure 1-2 on page 13, is a Mixer Connection Kit.

Strona 4 - Warranty

12 General InformationIntroduction• PSA Series E4440A, E4446A, and E4448A spectrum analyzers require Option AYZ (LO OUT and IF IN connectors). The

Strona 5 - Assistance

13General InformationIntroductionFigure 1-2 Mixer Connection Kit, Option 009

Strona 6

14 General InformationSpecificationsSpecificationsSpecifications for the 11970 Series Mixers are listed in Table 1-1 on page 15 through Table 1-7

Strona 7 - Contents

15General InformationSpecificationsTable 1-1 11970 Series SpecificationsDescription Specifications Supplemental InformationLO Amplitude Range 14 to

Strona 8

16 General InformationSpecificationsTable 1-2 11970K SpecificationsDescription Specifications Supplemental InformationRF Frequency Range 18 to 26

Strona 9 - General Information

17General InformationSpecificationsTable 1-3 11970A SpecificationsDescription Specifications Supplemental InformationRF Frequency Range 26.5 to 40 G

Strona 10 - Introduction

18 General InformationSpecificationsTable 1-4 11970Q SpecificationsDescription Specifications Supplemental InformationRF Frequency Range 33 to 5

Strona 11 - 11970 Series Harmonic Mixers

19General InformationSpecificationsTable 1-5 11970U SpecificationsDescription Specifications Supplemental InformationRF Frequency Range 40 to 60 GH

Strona 12

Notices© Agilent Technologies, Inc. 2011-2012No part of this manual may be reproduced in any form or by any means (including electronic storage and re

Strona 13 - General Information

20 General InformationSpecificationsTable 1-6 11970V SpecificationsDescription Specifications Supplemental InformationRF Frequency Range 50 to 7

Strona 14 - Specifications

21General InformationSpecificationsTable 1-7 11970W SpecificationsDescription Specifications Supplemental InformationRF Frequency Range 75 to 110 G

Strona 15

22 General InformationSpecificationsPHYSICAL CHARACTERISTICSModelFlange11. Waveguide attachment screws enter blind holes in the flanges of the mix

Strona 16

232 Operation

Strona 17

24 OperationIntroductionIntroductionThis section provides information on how to make effective use of the 11970 mixers.Operating PrecautionsRefer

Strona 18

25OperationGetting StartedGetting StartedThe 11970 series of millimeter wave mixers have no bias or back-short adjustments. 11970 Mixers require an L

Strona 19

26 OperationUsing the Mixers with the E4407B Spectrum Analyzer (Option AYZ)Using the Mixers with the E4407B Spectrum Analyzer (Option AYZ)The Agil

Strona 20

27OperationUsing the Mixers with the E4407B Spectrum Analyzer (Option AYZ)Amplitude CalibrationThe conversion loss versus frequency data can be enter

Strona 21

28 OperationUsing the Mixers with the E4407B Spectrum Analyzer (Option AYZ)Manually Entering Conversion-Loss Data 1. The analyzer frequency band w

Strona 22

29OperationUsing the Mixers with the E4407B Spectrum Analyzer (Option AYZ)Figure 2-2 Identification of valid responses is achieved by simply turning

Strona 23 - Operation

In This Guide…This guide contains the following information: 1 General InformationThis chapter covers equipment supplied, the mixers and options th

Strona 24

30 OperationUsing the Mixers with the E4440A, E4446A, or E4448A PSA Series Spectrum Analyzer (Option AYZ)Using the Mixers with the E4440A, E4446A,

Strona 25 - Getting Started

31OperationUsing the Mixers with the E4440A, E4446A, or E4448A PSA Series Spectrum Analyzer (Option AYZ)Amplitude CalibrationThe conversion loss vers

Strona 26 - (Option AYZ)

32 OperationUsing the Mixers with the E4440A, E4446A, or E4448A PSA Series Spectrum Analyzer (Option AYZ)NOTE More correction points entered acros

Strona 27 - File, then Load

33OperationUsing the Mixers with the E4440A, E4446A, or E4448A PSA Series Spectrum Analyzer (Option AYZ)Figure 2-6

Strona 28

34 OperationUsing the 11970A, Q, U, V, and W Mixers with the X- Series Signal Analyzers (Option EXM)Using the 11970A, Q, U, V, and W Mixers with t

Strona 29

35OperationUsing the 11970A, Q, U, V, and W Mixers with the X- Series Signal Analyzers (Option EXM)frequency or a start and stop frequency.7. Many re

Strona 30 - Set up the equipment

36 OperationUsing the 11970A, Q, U, V, and W Mixers with the X- Series Signal Analyzers (Option EXM)Down loading the conversion loss .csv files to

Strona 31

37OperationUsing the 11970A, Q, U, V, and W Mixers with the X- Series Signal Analyzers (Option EXM)Loading the .csv file automatically populates the

Strona 32

38 OperationUsing the 11970A, Q, U, V, and W Mixers with the X- Series Signal Analyzers (Option EXM)Signal IDImage SuppressThe Image Suppress mode

Strona 33 - Figure 2-6

39OperationUsing the Mixers with the 856X Series Spectrum AnalyzersUsing the Mixers with the 856X Series Spectrum AnalyzersExternal millimeter mixers

Strona 34

CertificationAgilent Technologies certifies that this product met its published specifications at the time of shipment from the factory. Agilent Techn

Strona 35 - Amplitude Calibration

40 OperationUsing the Mixers with the 856X Series Spectrum AnalyzersSelect the Frequency Band 2. Specify unpreselected external mixing by pressing

Strona 36

41OperationUsing the Mixers with the 856X Series Spectrum AnalyzersIn this example, we'll look at U-band, which ranges from 40 GHz to 60 GHz, as

Strona 37

42 OperationUsing the Mixers with the 856X Series Spectrum AnalyzersFigure 2-10 Store and correct for conversion loss. The second method for stor

Strona 38 - Image Shift

43OperationUsing the Mixers with the 856X Series Spectrum AnalyzersFigure 2-11 Signal Responses Produced by a 50 GHz Signal in U Band Identify signa

Strona 39

44 OperationUsing the Mixers with the 856X Series Spectrum AnalyzersFigure 2-12 Response for Invalid Signals Figure 2-13 Response for Valid Sign

Strona 40 - Select the Frequency Band

45OperationUsing the Mixers with the 856X Series Spectrum AnalyzersIdentify signals in wide frequency spans 7. SIG ID AT MKR identifies signals in wi

Strona 41

46 OperationUsing the Mixers with the 856X Series Spectrum AnalyzersFigure 2-15 SIG ID AT MKR Performed on a True Signal

Strona 42 - Signal Identification

47OperationUsing the Mixers with MMS AnalyzersUsing the Mixers with MMS AnalyzersPreliminary OperationNOTE This section provides information for the

Strona 43

48 OperationUsing the Mixers with MMS AnalyzersOperationBand SelectionUse the following key sequence to enter the external mixing mode and to sele

Strona 44

49OperationUsing the Mixers with MMS AnalyzersGeneral Descriptions of Agilent 71000 Series Spectrum Analyzer External-Mixing Functionsext mixer All

Strona 45

LIMITATION OF WARRANTYThe foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by Buyer, Buyer-supplied sof

Strona 46

50 OperationUsing the Mixers with MMS AnalyzersCONV LOSS (conversion loss) Offsets the reference level to compensate for amplitude losses at the

Strona 47 - Preliminary Operation

51OperationUsing the Mixers with MMS AnalyzersNOTE See the table below for available frequency ranges and related harmonic numbers. Use the IMAGE N S

Strona 48

52 OperationUsing the Mixers with MMS AnalyzersConversion Loss Versus Frequency CorrectionThe Agilent 71000 Series Spectrum Analyzers with the Agi

Strona 49

53OperationUsing the Mixers with MMS AnalyzersTo print out an existing AMPCOR table, use the program listed below:10 dim A$ (1:20) [30]20 OUTPUT 718;

Strona 50

54 OperationUsing the Mixers with the 8566B Spectrum AnalyzerUsing the Mixers with the 8566B Spectrum AnalyzerSet up the equipment1. Connect the e

Strona 51 - Use the

55OperationUsing the Mixers with the 8566B Spectrum Analyzerstands for locked, or you could press Shift+z to manually harmonic lock. Figure 2-18 TYPI

Strona 52

56 OperationUsing the Mixers with the 8566B Spectrum AnalyzerSignal IdentificationFigure 2-18 on page 55 shows a typical full-band display of a si

Strona 53

57OperationUsing the Mixers with the 8566B Spectrum AnalyzerFigure 2-19

Strona 54

58 OperationUsing the Mixers with the 8566B Spectrum AnalyzerFigure 2-20

Strona 55

593 Service

Strona 57 - Figure 2-19

60 ServiceMaintenanceMaintenanceThe only maintenance required for the 11970 Series Mixers is preventive maintenance. When you are not using your m

Strona 58 - Figure 2-20

61ServiceMaintenanceFigure 3-1 11970 Series Mixer Schematic DiagramModel LPF Fco (GHz)11970K 4.411970A 5.011970Q 5.011970U 6.211970V 5.411970W 6.2

Strona 59 - 3 Service

62 ServiceMaintenanceTable 3-1 Accessories and Replaceable PartsPart Number Description5061-5460:5061-54588710-05108710-0523Mixer Connector Kit (

Strona 60 - Maintenance

63ServiceMaintenanceTable 3-2 Locations for Agilent Technologies Online assistance: http://www.agilent.com/find/assistAmericasCanada 1 877 894 4414L

Strona 61