Agilent Technologies N9320A Instrukcja Obsługi

Przeglądaj online lub pobierz Instrukcja Obsługi dla Multimetry Agilent Technologies N9320A. Agilent Technologies N9320A Technical data Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 144
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - Spectrum Analyzer

Agilent N9320ASpectrum AnalyzerProgrammer’s Guide

Strona 2

4 N9320A Programmer’s Guide1 Getting Started4 After a while, the PC finds your N9320A as a new hardware and prompts a message saying “Found new hardwa

Strona 3 - In This Guide…

94 N9320A Programmer’s Guide5 Command ReferenceSENSe SubsystemSets the instrument state parameters so that you can measure the input signal. SENSe sub

Strona 4 - N9320A Programmer’s Guide

Command Reference 5N9320A Programmer’s Guide 95• EXP (Exponential Averaging mode) — When you set Avg Mode to Exp, each successive data acquisition af

Strona 5 - Contents

96 N9320A Programmer’s Guide5 Command ReferenceWhen set to manual, the last measured value is captured and held, or may be entered by the user. Relati

Strona 6

Command Reference 5N9320A Programmer’s Guide 97Set the Measurement Method[:SENSe]:ACPower:METHod IBW|RBW[:SENSe]:ACPower:METHod?Enables you to set the

Strona 7 - Getting Started

98 N9320A Programmer’s Guide5 Command ReferenceThis command, along with commands [:SENSe]:ACPower:OFFSet:LIST[:FREQuency] and [:SENSe]:ACPower:OFFSet:

Strona 8 - ® 2000 Professional, service

Command Reference 5N9320A Programmer’s Guide 99command with only four paramenters(ACP:OFFS:LIST:STAT ON,ON,ON,OFF) will result in the fifth and sixth

Strona 9

100 N9320A Programmer’s Guide5 Command Reference[:SENSe]:CHPower SubsectionSet the Average [:SENSe]:CHPower:AVERage:COUNt <integer>[:SENSe]:CHPo

Strona 10

Command Reference 5N9320A Programmer’s Guide 101*RST: EXPonentialExample: CHP:AVG:TCON EXPKey access: > Channel Power > Avg ModeSet the Channel

Strona 11

102 N9320A Programmer’s Guide5 Command Reference[:SENSe]:CORRection SubsectionExternal Amplifier Correction[:SENSe]:CORRection:OFFSet[:MAGNitude] <

Strona 12 - About USB Interface

Command Reference 5N9320A Programmer’s Guide 103Set the Average Mode[:SENSe]:OBWidth:AVERage:TCONrol EXPonen-tial|REPeat[:SENSe]:OBWidth:AVERage:TCONr

Strona 13 - Programming Fundamentals

Getting Started 1N9320A Programmer’s Guide 57 Windows should find USB Test and Measurement Device. Select it and press Next.8 The wizard will guide yo

Strona 14 - Overview

104 N9320A Programmer’s Guide5 Command Referencebandwidth, and the occupied bandwidth results is displayed in the data window. If the power of the adj

Strona 15

Command Reference 5N9320A Programmer’s Guide 105Set the X dB value[:SENSe]:OBWidth:XDB <dB value>[:SENSe]:OBWidth:XDB?Enables you to specify the

Strona 16 - Command Categories

106 N9320A Programmer’s Guide5 Command ReferenceSet the Average Mode[:SENSe]:TOI:AVERage:TCONrol EXPonential|REPeat[:SENSe]:TOI:AVERage:TCONrol?Press

Strona 17 - Command Syntax

Command Reference 5N9320A Programmer’s Guide 107level. For example, as the reference level changes, the input attenuator changes to ensure that a sign

Strona 18 - Command Example

108 N9320A Programmer’s Guide5 Command Reference[:SENSe]:SEMask SubsectionSet the Average[:SENSe]:SEMask:AVERage:COUNt <integer>[:SENSe]:SEMask:

Strona 19 - Creating Valid Commands

Command Reference 5N9320A Programmer’s Guide 109Set the Channel Res BW[:SENSe]:SEMask:BANDwidth|BWIDth[:RESolu-tion]:AUTO OFF|ON|0|1[:SENSe]:SEMask:BA

Strona 20 - Program and Response Messages

110 N9320A Programmer’s Guide5 Command Reference<freq>,...[<freq>] (up to five values)[:SENSe]:SEMask:BANDwidth|BWIDth[:RESolution]?Specif

Strona 21 - Parameters in Commands

Command Reference 5N9320A Programmer’s Guide 111Set the Stop Freq[:SENSe]:SEMask:OFFSet:LIST:FREQuency:STOP <freq>,...[<freq>] (up to five

Strona 22 - Variable Parameters

112 N9320A Programmer’s Guide5 Command ReferenceSet the Abs Start[:SENSe]:SEMask:OFFSet:LIST:STARt:ABSolute <ampl>,...[<ampl>] (up to five

Strona 23 - Status Registers

Command Reference 5N9320A Programmer’s Guide 113Set the Abs Stop[:SENSe]:SEMask:OFFSet:LIST:STARt:ABSolute <ampl>,...[<ampl>] (up to five

Strona 24

6 N9320A Programmer’s Guide1 Getting StartedAbout USB InterfaceA USB connection is typically easy to setup and very cost effective. The USB specificat

Strona 25 - Access the status registers

114 N9320A Programmer’s Guide5 Command ReferenceCouple and Man. If set to Couple, this is coupled to Rel Start to make a flat limit line. If set to M

Strona 26

Command Reference 5N9320A Programmer’s Guide 115Set the Sweep Time[:SENSe]:SEMask:SWEeptime <number>[:SENSe]:SEMask:SWEeptime?[:SENSe]:SEMask:SW

Strona 27

116 N9320A Programmer’s Guide5 Command ReferenceTurn Averagi ng On/O ff[:SENSe]:AVERage[:STATe] OFF|ON|0|1[:SENSe]:AVERage[:STATe]?This command toggle

Strona 28 - Status Register Examples

Command Reference 5N9320A Programmer’s Guide 117Type of Averaging for Measurements[:SENSe]:AVERage:TYPE VIDeo|RMS[:SENSe]:AVERage:TYPE?Successive meas

Strona 29 - Status Register System

118 N9320A Programmer’s Guide5 Command ReferenceVideo Bandwidth[:SENSe]:BANDwidth|BWIDth:VIDeo <freq>[:SENSe]:BANDwidth|BWIDth:VIDeo?Specifies t

Strona 30 - The Status Byte Register

Command Reference 5N9320A Programmer’s Guide 119Selects auto or manual mode for video bandwidth to resolution bandwidth ratio.Refer to User’s Guide fo

Strona 31

120 N9320A Programmer’s Guide5 Command ReferenceTyp e of Dete c tion[:SENSe]:DETector[:FUNCtion]NEGative|POSi-tive|SAMPle|AVERage|RMS|NORMAL[:SENSe]:

Strona 32 - 3 4 5 6 7

Command Reference 5N9320A Programmer’s Guide 121[:SENSe]:FREQuency SubsectionCenter Frequency[:SENSe]:FREQuency:CENTer <freq>[:SENSe]:FREQuency:

Strona 33

122 N9320A Programmer’s Guide5 Command Reference*RST: 3.0 GHzDefault Unit: HzKey access: > Span|Zero SpanFull Frequency Span[:SENSe]:FREQuency:SPA

Strona 34

Command Reference 5N9320A Programmer’s Guide 123[:SENSe]:POWer SubsectionInput Attenuation[:SENSe]:POWer[:RF]:ATTenuation <rel_ampl>[:SENSe]:POW

Strona 35 - Programming Example

sAgilent N9320A Spectrum AnalyzerProgrammer’s Guide72Programming FundamentalsOverview 8Command Categories 10Command Syntax 11Creating Valid Commands

Strona 36

124 N9320A Programmer’s Guide5 Command Reference[:SENSe]:SWEep SubsectionSweep Time[:SENSe]:SWEep:TIME <time>[:SENSe]:SWEep:TIME?Specifies the t

Strona 37

Command Reference 5N9320A Programmer’s Guide 125SOURce SubsystemThe SOURce subsystem controls the signal characteristics of the tracking generator. Re

Strona 38 - Example Program

126 N9320A Programmer’s Guide5 Command ReferenceAutomatic Source Attenuation:SOURce:POWer:ATTenuation:AUTO OFF|ON|0|1:SOURce:POWer:ATTenuation:AUTO?Se

Strona 39 - #include “visa.h”

Command Reference 5N9320A Programmer’s Guide 127Set the Source Sweep Power Range:SOURce:POWer:SPAN <rel_ampl>:SOURce:POWer:SPAN?Specifies the ra

Strona 40 - Device Sessions

128 N9320A Programmer’s Guide5 Command ReferenceRange: Integer, 0 to 4095Remarks: This command is not needed with the 1.5 GHz tracking generator.Key A

Strona 41

Command Reference 5N9320A Programmer’s Guide 129SYSTem SubsystemThis subsystem is used to set the controls and parameters associated with the overall

Strona 42 - Closing a Session

130 N9320A Programmer’s Guide5 Command ReferenceDisplay Software Information:SYSTem:CONFigure:SOFTware:STATe OFF|ON|0|1:SYSTem:CONFigure:SOFTware:STAT

Strona 43 - Checking USB Connection

Command Reference 5N9320A Programmer’s Guide 131Error Information Query:SYSTem:ERRor[:NEXT]?This command queries the earliest entry to the error queue

Strona 44 - 4 Programming Example

132 N9320A Programmer’s Guide5 Command ReferencePersistent State Reset:SYSTem:PRESet:PERSistentSets the persistent state values to their factory defau

Strona 45 - N9320A Programmer’s Guide 39

Command Reference 5N9320A Programmer’s Guide 133TRACe SubsystemThe TRACe subsystem controls access to the internal trace memory of the analyzer.Transf

Strona 46 - 40 N9320A Programmer’s Guide

8 N9320A Programmer’s Guide2 Programming FundamentalsOverviewThis section is not intended to teach you everything about the SCPI (Standard Commands fo

Strona 47 - N9320A Programmer’s Guide 41

134 N9320A Programmer’s Guide5 Command ReferenceTRIGger SubsystemThe TRIGger subsystem is used to set the controls and parameters associated with trig

Strona 48 - 42 N9320A Programmer’s Guide

Command Reference 5N9320A Programmer’s Guide 135display of trace data prior to the trigger event. A positive trigger offset value results in an effect

Strona 49 - N9320A Programmer’s Guide 43

136 N9320A Programmer’s Guide5 Command ReferenceVideo Trigger Level Amplitude:TRIGger[:SEQuence]:VIDeo:LEVel <ampl>:TRIGger[:SEQuence]:VIDeo:LEV

Strona 50 - 44 N9320A Programmer’s Guide

Command Reference 5N9320A Programmer’s Guide 137UNIT SubsystemSelect Power Units of Measure:UNIT:POWer DBM|DBMV|DBUV|DBUA|V|W|A:UNIT:POWer?Specifies a

Strona 51 - N9320A Programmer’s Guide 45

138 N9320A Programmer’s Guide5 Command Reference

Strona 52 - Measuring Phase Noise

Programming Fundamentals 2N9320A Programmer’s Guide 9Common Terms used in this BookThe SCPI Consortium or IEEE can provide detailed information on the

Strona 53 - N9320A Programmer’s Guide 47

10 N9320A Programmer’s Guide2 Programming FundamentalsCommand CategoriesThe SCPI command falls into two categories: • Subsystem commands that simulate

Strona 54 - 48 N9320A Programmer’s Guide

Programming Fundamentals 2N9320A Programmer’s Guide 11Command SyntaxA command consists of mnemonics (keywords), parameters and punctuation. Before you

Strona 55 - Command Reference

12 N9320A Programmer’s Guide2 Programming FundamentalsCommand Statement Rules OverviewBesides the standard notation of SCPI described above, please re

Strona 56 - IEEE Common Commands

Programming Fundamentals 2N9320A Programmer’s Guide 13Creating Valid CommandsCommands are not case sensitive and there are often many different ways o

Strona 57 - Operation Complete Query

Notices© Agilent Technologies, Inc. 2006-2007No part of this manual may be reproduced in any form or by any means (including electronic storage and re

Strona 58 - Status Byte Query

14 N9320A Programmer’s Guide2 Programming FundamentalsProgram and Response MessagesTo understand how your instrument and controller communicate using

Strona 59 - CALCulate Subsystem

Programming Fundamentals 2N9320A Programmer’s Guide 15Parameters in CommandsThere are four basic types of parameters: boolean, key words, variables an

Strona 60 - NdBstate

16 N9320A Programmer’s Guide2 Programming FundamentalsVariable Parameters<ampl>,<rel_ampl>The <ampl> (amplitude) parameter and the &

Strona 61 - CALCulate:LLINe Subsection

sAgilent N9320A Spectrum AnalyzerProgrammer’s Guide173Status RegistersOverview 18How to use the Status Registers 21Status Register System 23This chap

Strona 62 - Delete Limit Line

18 N9320A Programmer’s Guide3 Status RegistersOverviewWhen you are programming the instrument you may need to monitor instrument status to check for e

Strona 63 - Set the Margin Size

Status Registers 3N9320A Programmer’s Guide 19NegativeTransit ionRegisterThis filter register controls which signals will set a bit in the event regis

Strona 64 - Select the Type of Limit Line

20 N9320A Programmer’s Guide3 Status RegistersWhat are Status Register SCPI CommandsMost monitoring of the instrument conditions is done at the highes

Strona 65 - CALCulate:MARKer Subsection

Status Registers 3N9320A Programmer’s Guide 21How to use the Status RegistersA program often needs to detect and manage error conditions or changes in

Strona 66 - Frequency Counter Marker

22 N9320A Programmer’s Guide3 Status Registersthis condition occurred even if the condition no longer exists. The event register can only be cleared b

Strona 67

Status Registers 3N9320A Programmer’s Guide 23Status Register SystemThe hardware status registers are combined to form the instrument status system. S

Strona 68 - Define Peak Search

N9320A Programmer’s Guide In This Guide…This guide contains programming information for the N9320A Spectrum Analyzer.1 Getting StartedPrepare for the

Strona 69 - Threshold Hidden

24 N9320A Programmer’s Guide3 Status RegistersThe Status Byte RegisterThe RQS bit is read and reset by a serial poll. The same bit position (MSS) is r

Strona 70 - Set the Phase Noise Offset

Status Registers 3N9320A Programmer’s Guide 25The status byte register contains the following bits:To query the status byte register, send the *STB co

Strona 71 - Read Phase Noise

26 N9320A Programmer’s Guide3 Status RegistersStandard Event Status RegisterThe standard event status register is used to determine the specific event

Strona 72 - > Mkr –> Stop

Status Registers 3N9320A Programmer’s Guide 27The standard event status register contains following bits:The standard event status register is used to

Strona 73 - Marker to Trace Auto

28 N9320A Programmer’s Guide3 Status Registers*ESE <integer> command where <integer> is the sum of the decimal values of the bits you want

Strona 74

sAgilent N9320A Spectrum AnalyzerProgrammer’s Guide294Programming ExampleOverview 30Programming in C using the VTL 31Checking USB Connection 37Using

Strona 75 - Span Markers Span X Value

30 N9320A Programmer’s Guide4 Programming ExampleOverviewThe programming examples in this section keep to the following 3 conventions:• The programmin

Strona 76 - CALCulate:NTData Subsection

Programming Example 4N9320A Programmer’s Guide 31Programming in C using the VTLThis section includes some basic information about programming in the C

Strona 77 - CALibration Subsystem

32 N9320A Programmer’s Guide4 Programming ExampleExample ProgramThis example program queries a USB device for an identification string and prints the

Strona 78

Programming Example 4N9320A Programmer’s Guide 33viStatus=viOpen(defaultRM,"USB0::2391::8472::0000000000::0::INSTR",VI_NULL,VI_NULL,&viN

Strona 79 - CONFigure Subsystem

N9320A Programmer’s Guide

Strona 80 - Query the measurement State

34 N9320A Programmer’s Guide4 Programming ExampleOpening a SessionA session is a channel of communication. Sessions must first be opened on the defaul

Strona 81 - DISPlay Subsystem

Programming Example 4N9320A Programmer’s Guide 35Next, you open a session with a specific device with the viOpen function. This function uses the ses

Strona 82

36 N9320A Programmer’s Guide4 Programming ExampleAddressing a SessionAs seen in the previous section, the rsrcName parameter in the viOpen function

Strona 83 - Normalized Reference Level

Programming Example 4N9320A Programmer’s Guide 37Checking USB ConnectionUsually, using “*IDN?” verifies the data transferring between the controller P

Strona 84

38 N9320A Programmer’s Guide4 Programming ExampleUsing C with Marker Peak Search and Peak Excursion/**************************************************

Strona 85

Programming Example 4N9320A Programmer’s Guide 39#include <stdio.h>#include <stdlib.h>#include <math.h>#include <ctype.h>#incl

Strona 86 - FETCh Subsystem

40 N9320A Programmer’s Guide4 Programming Example/*Open a USB session.*/viStatus=viOpenDefaultRM(&defaultRM);viStatus=viOpen(defaultRM,"USB0:

Strona 87 - SEM measurement

Programming Example 4N9320A Programmer’s Guide 41/*Set the peak excursion*/viPrintf(viN9320A,"CALC:MARK:PEAK:EXC %1fDB \n",fPeakExcursion);/

Strona 88 - TOI measurement

42 N9320A Programmer’s Guide4 Programming ExampleUsing Marker Delta Mode and Marker Minimum Search/***************************************************

Strona 89 - INITiate Subsystem

Programming Example 4N9320A Programmer’s Guide 43#include <stdio.h>#include <stdlib.h>#include <math.h>#include <ctype.h>#incl

Strona 90 - Take New Data Acquisitions

N9320A Programmer’s GuideContents1 Getting Started 1Remotely Operating Your N9320A 22 Programming Fundamentals 7Overview 8Command Categories 10Command

Strona 91 - MMEMory Subsystem

44 N9320A Programmer’s Guide4 Programming Example/* Open an USB session*/ viStatus=viOpenDefaultRM(&defaultRM);viStatus=viO-pen(default

Strona 92

Programming Example 4N9320A Programmer’s Guide 45/*Set the analyzer to the values given by the user*///viPrintf(viN9320A,"SENS:FREQ:STAR %lf //MH

Strona 93 - Store a Limit Line in a File

46 N9320A Programmer’s Guide4 Programming ExampleMeasuring Phase Noise/************************************************************//* Measuring Phase

Strona 94 - Store a Trace in a File

Programming Example 4N9320A Programmer’s Guide 47ViSession defaultRM, viN9320A;ViStatus errStatus;ViChar cIdBuff[256]= {0};char cEnter = 0;int iResult

Strona 95 - OUTPut Subsystem

48 N9320A Programmer’s Guide4 Programming Example/*Reset the Instrument*/viPrintf(viN9320A,"*RST\n");/*Display the program heading */printf(

Strona 96 - READ Subsystem

sAgilent N9320A Spectrum AnalyzerProgrammer’s Guide495Command ReferenceIEEE Common Commands 50CALCulate Subsystem 53CALibration Subsystem 71CONFigure

Strona 97

50 N9320A Programmer’s Guide5 Command ReferenceIEEE Common CommandsThe first few pages of this chapter contain common commands specified in IEEE Stand

Strona 98

Command Reference 5N9320A Programmer’s Guide 51Standard Event Status Register Query*ESR?Queries and clears the standard event status event register. (

Strona 99 - Read the TOI (IP 3)

52 N9320A Programmer’s Guide5 Command ReferenceReset*RSTThis command presets the instrument to a factory defined condition that is appropriate for rem

Strona 100 - SENSe Subsystem

Command Reference 5N9320A Programmer’s Guide 53CALCulate SubsystemThis subsystem is used to perform post- acquisition data processing. In effect, the

Strona 101 - Set ACP Reference Auto

N9320A Programmer’s GuideContentsCALCulate:MARKer Subsection 59CALCulate:NTData Subsection 70CALibration Subsystem 71CONFigure Subsystem 73DISPlay Sub

Strona 102 - Set ACP to Total Pwr Ref

54 N9320A Programmer’s Guide5 Command ReferenceNdBstate:CALCulate:BWIDth|BANDwidth[:STATe] OFF|ON|0|1:CALCulate:BWIDth|BANDwidth[:STATe]?Controls the

Strona 103 - Set the Ref BW

Command Reference 5N9320A Programmer’s Guide 55CALCulate:LLINe SubsectionLimit lines can be defined for your measurement. You can then have the instru

Strona 104 - Set the Offset Freq

56 N9320A Programmer’s Guide5 Command ReferenceRemarks: If two amplitude values are entered for the same frequency, a single vertical line is the resu

Strona 105 - Set the Measurement Type

Command Reference 5N9320A Programmer’s Guide 57Display the Limit Line:CALCulate:LLINe[1]|2:DISPlay OFF|ON|0|1:CALCulate:LLINe[1]|2:DISPlay?Controls th

Strona 106 - [:SENSe]:CHPower Subsection

58 N9320A Programmer’s Guide5 Command ReferenceDisplay the Limit Margin:CALCulate:LLINe[1]|2:MARGin:STATe OFF|ON|0|1:CALCulate:LLINe[1]|2:MARGin:STATe

Strona 107 - Set the Channel Power Span

Command Reference 5N9320A Programmer’s Guide 59CALCulate:MARKer SubsectionMarkers All Off on All Traces:CALCulate:MARKer:AOFFTurns off all markers on

Strona 108 - Amplitude

60 N9320A Programmer’s Guide5 Command ReferenceFrequency Counter Marker Automatic Resolution:CALCulate:MARKer:FCOunt:RESolution:AUTO OFF|ON|0|1:CALCul

Strona 109 - Set OBW Span

Command Reference 5N9320A Programmer’s Guide 61Marker Peak (Maximum) Search:CALCulate:MARKer[n]:MAXimumPerforms a peak search based on the search mode

Strona 110 - Set the Occ BW% Pwr

62 N9320A Programmer’s Guide5 Command ReferenceMarker Mode:CALCulate:MARKer[n]:MODE POSition|DELTa:CALCulate:MARKer[n]:MODE?Selects the type of marker

Strona 111 - [:SENSe]:TOI Subsection

Command Reference 5N9320A Programmer’s Guide 63Remarks: If mode is set to MAXimum, peak search will place the marker at the maximum amplitude in the t

Strona 112 - Set the Max Mixer Lvl

sAgilent N9320A Spectrum AnalyzerProgrammer’s Guide11Getting StartedPreparing equipment for Remote Operation 2Connecting the N9320A to a PC via the U

Strona 113 - Set TOI Span

64 N9320A Programmer’s Guide5 Command ReferencePeak to Peak Delta Markers:CALCulate:MARKer[1]|2|3|4:PTPeakPositions delta markers on the highest and l

Strona 114 - [:SENSe]:SEMask Subsection

Command Reference 5N9320A Programmer’s Guide 65Optimize Phase Noise:CALCulate:MARKer:PHNoise:OPTimize ON|OFF|1|0Turns on/off the phase noise optimizat

Strona 115 - Set the Offset Res BW

66 N9320A Programmer’s Guide5 Command ReferenceSet Reference Level to the Marker Value:CALCulate:MARKer[n][:SET]:RLEVelSets the reference level to the

Strona 116 - Set the Start Freq

Command Reference 5N9320A Programmer’s Guide 67Marker On/Off:CALCulate:MARKer[n]:STATe OFF|ON|0|1:CALCulate:MARKer[n]:STATe?Turns the selected marker

Strona 117 - SEM:OFFS:LIST:SWE:AUTO 40 ms

68 N9320A Programmer’s Guide5 Command ReferenceTurns on or off marker signal tracking. It continuously puts the selected marker on the highest display

Strona 118 - Set the Rel Start

Command Reference 5N9320A Programmer’s Guide 69Set the Delta Marker :CALCulate:MARKer[n]:X:DELTa <param>:CALCulate:MARKer[n]:X:DELTa?Activates a

Strona 119 - Set the Rel Stop

70 N9320A Programmer’s Guide5 Command ReferenceMarker Read Y Value:CALCulate:MARKer[n]:Y?Read the current Y value for the designated marker or delta o

Strona 120 - Set the Fail Mask

Command Reference 5N9320A Programmer’s Guide 71CALibration SubsystemThese commands control the self- alignment processes.Align All Instrument Assembli

Strona 121 - [:SENSe]:AVERage Subsection

72 N9320A Programmer’s Guide5 Command ReferenceSelect the Source State for Calibration:CALibration:SOURce:STATe OFF|ON|0|1:CALibration:SOURce:STATe?Co

Strona 122 - Turn Averagi ng On/O ff

Command Reference 5N9320A Programmer’s Guide 73CONFigure SubsystemACP measurement State:CONFigure:ACPowerThis command places the analyzer in Adjacent

Strona 123 - [:SENSe]:BANDwidth Subsection

2 N9320A Programmer’s Guide1 Getting StartedRemotely Operating Your N9320AThe signal generator provides USB (Universal Serial Bus) connection and allo

Strona 124 - Video Bandwidth Automatic

74 N9320A Programmer’s Guide5 Command ReferenceSpecturm Emission Mask measurement State:CONFigure:SEMaskThis command places the analyzer in Spectrum E

Strona 125 - [:SENSe]:DETector Subsection

Command Reference 5N9320A Programmer’s Guide 75DISPlay SubsystemThe DISPlay subsystem controls the selection and presentation of textual, graphical, a

Strona 126 - Detector

76 N9320A Programmer’s Guide5 Command ReferenceTurn the Entire Display On/Off:DISPlay:ENABle OFF|ON|0|1:DISPlay:ENABle?Turns the display on or off. Ha

Strona 127 - Frequency

Command Reference 5N9320A Programmer’s Guide 77Display Line On/Off:DISPlay:WINDow:TRACe:Y:DLINe:STATe OFF|ON|0|1:DISPlay:WINDow:TRACe:Y:DLINe:STATe?Tu

Strona 128

78 N9320A Programmer’s Guide5 Command ReferenceTrace Y-Axis Amplitude Scaling:DISPlay:WINDow:TRACe:Y[:SCALe]:PDIVision <rel_ampl>:DISPlay:WINDow

Strona 129

Command Reference 5N9320A Programmer’s Guide 79Remarks: The sum of (reference level offset + reference level) is clipped to the range –327.6 to 327.6

Strona 130 - [:SENSe]:SWEep Subsection

80 N9320A Programmer’s Guide5 Command ReferenceFETCh SubsystemThis command puts selected data from the most recent measurement into the output buffer.

Strona 131 - SOURce Subsystem

Command Reference 5N9320A Programmer’s Guide 81Channel Power measurement:FETCh:CHPower?This command returns scalar results of main channel power, and

Strona 132 - Sets the Output Power

82 N9320A Programmer’s Guide5 Command Referencefor store the lower statistical result for power(or PSD) offset.2. The emission mask offset of lower fr

Strona 133 - Output Power Tracking

Command Reference 5N9320A Programmer’s Guide 83INITiate SubsystemThe INITiate subsystem is used to control the initiation of the trigger. Refer to the

Strona 134 - Output Power Tracking Peak

Getting Started 1N9320A Programmer’s Guide 3Connecting the N9320A to a PC via the USB PortNo extra driver is required to connect the N9320A via the US

Strona 135 - SYSTem Subsystem

84 N9320A Programmer’s Guide5 Command Reference• When OFF, the trigger system remains in an “idle” state until CONTinuous is ON or :INITiate[:IMMedia

Strona 136 - Set Date

Command Reference 5N9320A Programmer’s Guide 85MMEMory SubsystemThe purpose of the MMEMory subsystem is to provide access to internal or external disk

Strona 137 - Power on Type

86 N9320A Programmer’s Guide5 Command ReferenceLoad a Limit Line from Memory to the Instrument:MMEMory:LOAD:LIMit LLINE1|LLINE2,<file_name>Loads

Strona 138 - Set Time

Command Reference 5N9320A Programmer’s Guide 87Load a Trace From a File to the Instrument:MMEMory:LOAD:TRACe <file_name>The contents of the file

Strona 139 - TRACe Subsystem

88 N9320A Programmer’s Guide5 Command ReferenceStore a Screen Image in a Graphic File:MMEMory:STORe:SCReen <file_name>Saves the current instrume

Strona 140 - TRIGger Subsystem

Command Reference 5N9320A Programmer’s Guide 89OUTPut SubsystemThe OUTPut subsystem controls the characteristics of the tracking generator output port

Strona 141 - Trigg er Sour ce

90 N9320A Programmer’s Guide5 Command ReferenceREAD SubsystemDoes not preset the measurement to the factory default settings. For example, if you have

Strona 142 - Video Trigger Level Amplitude

Command Reference 5N9320A Programmer’s Guide 91Channel Power measurement:READ:CHPower?Returns two values that correspond to the ChannelPower and Power

Strona 143

92 N9320A Programmer’s Guide5 Command ReferenceSEM measurement:READ:SEMask?Returns 20 scalar results, each five in a array, in the following order:1.

Strona 144 - 5 Command Reference

Command Reference 5N9320A Programmer’s Guide 9316. The upper Output Intercept Power value in dBm.17. The upper Output Intercept Power value in dBc.18.

Komentarze do niniejszej Instrukcji

Brak uwag